Atlas Pro 240 User Manual

GUARDIAN PRO
240 SeRieS
Requirements
• The light control requires 120-volts AC.
• If you want to use Manual Mode, the control must be wired through a switch.
Some codes require installati o n by a
qualified electrician.
• This product is intended for use with the enclosed gasket and with a junction box marked for use in wet locations.
Models MLGC240B MLGC240W
Features
• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• Photocell keeps the lighting off during daylight hours.
• LED indicates motion was sensed (day or night).
This package includes:
Bulb
Holders
Cover
Plate
Sensor
Light Control
Rubber Plug
Plastic Hanger
2 Wire
Connectors
OPERATION
Mode: On-Time Works: Day Night
Test Auto Manual Dual Light Level
Note: When first turned on wait about 1 1/2 minutes for
the circuitry to calibrate.
Put ON-TIME switch on the sensor bottom to TEST and the Dual Light Level switch OFF.
ON-TIME
TEST 1 5 20
5 Seconds x x
1, 5, or 20 Min x
To Dawn* x
3, 6 Hr, to Dawn x
* resets to Auto Mode at dawn.
TEST
DUAL LIGHT LEVEL
Off 3 6 Dusk to Dawn
AUTO
Mounting Bolt
2 Shells
© 2008 Atlas Lighting Products, Inc. 598-1094-04
Mounting Strap
Gasket
6 Screws
(3 sizes included)
Put the ON-TIME switch in the 1, 5, or 20 minute position.
MANUAL MODE
Manual mode only works at night because daylight returns the sen­sor to AUTO.
Flip the light switch off for one sec­ond then back on to toggle between AUTO and MANUAL MODE.
Manual mode works only with the ON-TIME switch in the 1, 5, or 20 position.
ON-TIME
TEST 1 5 20
1 Second OFF
then...
... back on.
240-028-A
Mode Switching Summary
MANUAL MODE
AUTO
TEST
INSTALLATION
Move ON-TIME Switch to
1, 5, or 20 minutes
Flip light switch off
for one second then
back on*
* If you get confused while switching modes, turn the
power off for one minute, then back on. After the cali­bration time the control will be in the AUTO mode.
Dual Light Level Timer
Light comes on half bright for selected time after dusk (Off, 3 hr., 6 hr., until dawn). Selecting OFF disables this feature. The motion sensing features will continue to work as described in this manual. If motion is sensed, the light turns on full bright for the ON-TIME (1, 5, or 20 minutes) then returns to dim mode.
For easy installation, select an existing light with a wall switch for replacement.
For best performance, mount the fixture about 8 ft. (2.4 m) above the ground. 8 ft. (2.4 m), aiming the sensor down will reduce coverage distance.
NOTE:
If fixture is mounted higher than
Wall Mount Eave Mount
For under eave installation, the sensor head must be rotated as shown in the next two steps for proper
operation and to avoid the risk of electrical shock.
For eave mount only:
Swing the sensor head towards the clamp screw
joint.
Controls
Clamp Screw
Then rotate the sensor head clockwise 180° so the
controls face down.
Controls
Controls
If the sensor pops out of the ball joint, loosen the clamp screw and push the sensor back into the ball joint. Tighten the clamp screw when done.
2
598-1094-04
Wire the Light Control
WARNING: Turn power off at circuit breaker
or fuse.
❒ Remove the existing light fixture. Install the mounting strap as shown using two screws
that fit your junction box.
The plastic hanger can be used to hold the fixture
while wiring. The small end of the plastic hanger can be threaded through the hole in the center of the cover plate. The small end then goes into one of the slots on the mounting strap.
❒ Route the light control’s wires through the large
gasket holes.
Twist the junction box wires and fixture wires together
as shown. Secure with wire connectors.
Mounting
Strap
Black to Black
White to White
Rubber
Plug
Mount the Light Control
Align the light control cover plate and cover plate
gasket. Secure with the mounting bolt.
Align the three slots in the decorative shell with the
bulb holder pins. Push the shell in and then twist clockwise to lock. Repeat for other shell.
Shell Slot
Push the rubber plug firmly into place. If a wet location junction box was not used, caulk
the wall plate mounting surface with silicone weather sealant.
To avoid water damage and electrical shock, keep bulb holders 30° below horizontal.
Gasket
Junction box ground wire to green ground screw on fixture.
Mounting
Bolt
Keep bulbs at least 1" (25 mm) from the
Lock Nut
❒ Adjust the bulb holders by loosening the lock nuts but
do not rotate the bulb holders more than 180° from the factory setting. When screwing in the floodlamps, do not overtighten.
sensor. Do not allow the bulbs to block the lens.Lens
598-1094-04
3
TEST AND ADJUSTMENT
B
O
O
S
T
MAX
MIN
RANGE
ON - TIME DUAL BRITE
TEST 1 5 20
MINUTES
OFF 3 6 DUSK TO
HOUR DAWN
Turn on the circuit breaker and light switch.
NOTE: Sensor has a 1 1/2 minute warm up period
before it will detect motion. When first turned on, wait 1 1/2 minutes.
Turn the RANGE control to the medium position
(halfway between MIN and MAX), Dual Light Level to OFF, and the ON-TIME control to the TEST position.
NOTE:
If fixture is mounted higher than 8 ft. (2.4 m), aiming the sensor down will reduce coverage distance. The detector is less sensitive to motion directly towards it.
MotionMotion
Sensor
Least Sensitive Most Sensitive
DUAL LIGHT LEVEL
Bottom of Sensor
Avoid aiming the control at:
• Objects that change temperature rapidly, such as heating vents and air conditioners. These heat sources could cause false triggering.
• Areas where pets or traffic may trigger the control.
Nearby large, light-colored objects reflecting light may trigger the shut-off feature. Do not point other lights at the sensor.
240°
8 ft.
(2.4 m)
70 ft.
(21 m)
100 ft. (30.5 m) Boosted
Maximum Range Maximum Coverage Angle
Loosen the clamp screw in the
sensor ball joint and gently rotate the sensor.
Walk through the coverage
area noting where you are
Clamp Screw
Ball Joint
when the lights turn on (also, the LED will flash several times when motion is detected). Move the sensor head up, down, or sideways to change the cover­age area. Keep the sensor at
least 1" (25 mm) away from
Aim Sensor
Down for Short
Coverage
the bulbs.
Adjust the RANGE as needed.
RANGE set too high may increase false triggering.
Secure the sensor head by
tightening the clamp screw.
Aim Sensor
Higher for Long
Coverage
Do not overtighten the screw.
Set the amount of TIME you want the lights to stay
on after motion is detected (1, 5, or 20 minutes).
Set the Dual Light Level switch to the amount of
time after dusk you want the lights on at low level (Off, 3, 6 Hrs., Dusk-to-Dawn).
WARNING: Risk of fire. Do not aim the bulbs
at a combustible surface within 3 ft. (1 m).
4
598-1094-04
SPECIFICATIONS
Range . . . . . . . . . . . . Up to 70 ft. (21 m); 100 ft.
(30.5 m) with Range Boost. [varies
with surrounding temperature]
Sensing Angle . . . . . . Up to 240°
Electrical Load . . . . . . Up to 300 Watt Maximum In-
candescent [Up to 150 Watt
maximum each bulb holder.]
Operating Modes . . . . TEST, AUTO and MANUAL
MODE
Time Delay . . . . . . . . 1, 5, 20 minutes
Dual Light Level . . . . . 3, 6 hours, Dusk-to-Dawn
Atlas Lighting Products, Inc. reserves the right to dis­continue products and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold.
Power Requirements . 120 VAC, 60 Hz Replacement Lamp . . Up to 150 Watt Maximum PAR38
Incandescent or Halogen (Not CFL) Bulbs.
TROUBLESHOOTING GUIDE
If you experience a problem with your Light Control, first follow this guide. For additional assistance write to:
Atlas Lighting Products, Inc. • Customer Service Department • P.O. Box 2348 • Burlington, NC 27216
SYMPTOM POSSIBLE CAUSE SOLUTION
Lights will not come on.
Lights come on in day­light.
Lights come on for no apparent reason.
Lights turn off too late in Dusk-to-Dawn setting.
Lights stay on continu­ously.
Lights flash on and off. 1. Heat or light from the flood lamps may be turning the
Lights flash once, then stay o ff i n man ual mode.
1. Light switch is turned off.
2. Flood lamp is loose or burned out.
3. Fuse is blown or circuit breaker is turned off.
4. Daylight turn-off is in effect.
5. Incorrect circuit wiring, if this is a new installation.
6. Light control aimed in wrong direction.
1. Light control may be installed in a relatively dark location.
2. Light control is in TEST.
1. Light control may be sensing small animals or auto­mobile traffic.
2. Range is set too high.
3. Dual Light Level is on.
Light control may be installed in a relatively dark loca­tion.
1. A flood lamp is positioned too close to the light control or pointed at nearby objects that cause heat to trigger the light control.
2. The light control may be picking up a heat source like an air vent, dryer vent, or brightly painted, heat­reflective surface.
3. Light control is in manual mode.
light control on and off.
2. Heat being reflected from other objects may be turn­ing the light control on and off.
3. Light control is in the TEST mode and warming up.
4. Light may be leaking through the flood lamp reflec­tors.
Light control is detecting its own lights. Reposition flood lamps to keep area below the light
1. Turn light switch on.
2. Check flood lamp and replace if burned out.
3. Replace fuse or turn circuit breaker on.
4. Recheck after dark.
5. Verify wiring is correct.
6. Re-aim light control to cover desired area.
1. The fixture is operating normally under these condi­tions.
2. Set control switch to 1, 5, or 10 minutes.
1. Re-aim light control.
2. Reduce range.
3. The fixture is operating normally under these condi­tions.
Relocate light control, or use 3 hr. or 6 hr. setting.
1. Reposition the flood lamp away from the light control or nearby objects.
2. Reduce range.
3. Switch light control to AUTO.
1. Reposition the flood lamp away from the light con­trol.
2. Reposition light control.
3. Flashing is normal under these conditions.
4. Replace the flood lamps with new high quality PAR 38 lamps. (Make sure the metal lamp protectors are installed).
control relatively dark.
598-1094-04
5
FIVE YEAR LIMITED WARRANTY
Atlas Lighting Products, Inc. warrants against defects in materials or workmanship for a period of five years from the date of purchase for use, and agrees to repair or, at our option, replace a defective unit without charge for either parts or labor. IMPORTANT: This warranty does not cover damage resulting from accident, misuse of abuse, lack of reasonable care, the affixing of any attachment not provided with product, alteration of any attachments factory installed, loss of parts or subjecting the fixture to any but the specified electrical service. This warranty does not cover failure of the bulb due to accidents, abuse, misuse, vandalism, power surges, and acts of nature such as lightning damage. No responsibility is assumed for any special incidental or consequential damages. Damages occurring during transit are not covered by this warranty-including UPS shipments. To obtain warranty service, mail sales receipt as proof-of-purchase, date and a brief explanation of the nature of the defect, to the address listed below. You will receive, by mail, a Return Goods Authorization number and full instructions for returning defective merchandise. All returned goods must be accompanied
by a Return Goods Authorization number issued by Atlas Lighting Products, Inc.
NOTE: No other warranty, written or verbal, is authorized by Atlas Lighting Products, Inc. This warranty gives you specific legal rights and you may also have other rights which vary from state to state. Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts, so the above exclusion and limitations may not apply to you.
For information regarding replacement parts please write to:
Atlas Lighting Products, Inc.
Attn: Customer Service Department
P.O. Box 2348
Burlington, NC 27216
6
598-1094-04
Notes / Notas _________________ _____________________________ _____________________________ _____________________________ _____________________________ _____________________________ _____________________________ _____________________________ _____________________________ _____________________________ _____________________________ _____________________________ _____________________________ _____________________________ _____________________________ _____________________________ _____________________________ _____________________________ _____________________________
598-1094-04
7
Notes / Notas _________________ _____________________________ _____________________________ _____________________________ _____________________________ _____________________________ _____________________________ _____________________________ _____________________________ _____________________________ _____________________________ _____________________________ _____________________________ _____________________________ _____________________________ _____________________________ _____________________________ _____________________________ _____________________________
8
598-1094-04
Loading...