Requirements
• The light control requires 120-volts AC.
• If you want to use Manual Mode, the control must be
wired through a switch.
• Some codes require installati o n by a
qualified electrician.
• This product is intended for use with the enclosed
gasket and with a junction box marked for use in wet
locations.
Models MLGC240B
MLGC240W
Features
• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• Dual Light Level.
• Photocell keeps the lighting off during daylight hours.
• LED indicates motion was sensed (day or night).
This package includes:
Bulb
Holders
Cover
Plate
Sensor
Light Control
Rubber Plug
Plastic Hanger
2 Wire
Connectors
OPERATION
Mode: On-Time Works: Day Night
Test
Auto
Manual
Dual Light
Level
Note: When first turned on wait about 1 1/2 minutes for
the circuitry to calibrate.
Put ON-TIME switch on the sensor bottom to TEST
and the Dual Light Level switch OFF.
ON-TIME
TEST 1 5 20
5 Seconds x x
1, 5, or 20 Min x
To Dawn* x
3, 6 Hr, to Dawn x
* resets to Auto Mode at dawn.
TEST
DUAL LIGHT LEVEL
Off 3 6 Dusk to
Dawn
AUTO
Mounting Bolt
2 Shells
© 2008 Atlas Lighting Products, Inc. 598-1094-04
Mounting Strap
Gasket
6 Screws
(3 sizes included)
Put the ON-TIME switch in the
1, 5, or 20 minute position.
MANUAL MODE
Manual mode only works at night
because daylight returns the sensor to AUTO.
Flip the light switch off for one second then back on to toggle between
AUTO and MANUAL MODE.
Manual mode works only with the
ON-TIME switch in the 1, 5, or 20
position.
ON-TIME
TEST 1 5 20
1 Second OFF
then...
... back on.
240-028-A
Mode Switching Summary
INSTALLATION
Move ON-TIME Switch to
1, 5, or 20 minutes
Flip light switch off
for one second then
back on*
* If you get confused while switching modes, turn the
power off for one minute, then back on. After the calibration time the control will be in the AUTO mode.
Dual Light Level Timer
Light comes on half bright for selected time after dusk
(Off, 3 hr., 6 hr., until dawn). Selecting OFF disables
this feature. The motion sensing features will continue
to work as described in this manual. If motion is sensed,
the light turns on full bright for the ON-TIME (1, 5, or
20 minutes) then returns to dim mode.
For easy installation, select an existing light with a wall
switch for replacement.
For best performance, mount the fixture about 8 ft. (2.4 m)
above the ground.
8 ft. (2.4 m), aiming the sensor down will reduce coverage
distance.
NOTE:
If fixture is mounted higher than
Wall Mount Eave Mount
For under eave installation, the sensor head must
be rotated as shown in the next two steps for proper
operation and to avoid the risk of electrical shock.
For eave mount only:
❒ Swing the sensor head towards the clamp screw
joint.
Controls
Clamp Screw
❒ Then rotate the sensor head clockwise 180° so the
controls face down.
Controls
Controls
If the sensor pops out of the ball joint, loosen the
clamp screw and push the sensor back into the ball
joint. Tighten the clamp screw when done.
2
598-1094-04
Wire the Light Control
WARNING: Turn power off at circuit breaker
or fuse.
❒ Remove the existing light fixture.
❒ Install the mounting strap as shown using two screws
that fit your junction box.
❒ The plastic hanger can be used to hold the fixture
while wiring. The small end of the plastic hanger
can be threaded through the hole in the center of
the cover plate. The small end then goes into one
of the slots on the mounting strap.
❒ Route the light control’s wires through the large
gasket holes.
❒ Twist the junction box wires and fixture wires together
as shown. Secure with wire connectors.
Mounting
Strap
Black to
Black
White to
White
Rubber
Plug
Mount the Light Control
❒ Align the light control cover plate and cover plate
gasket. Secure with the mounting bolt.
❒ Align the three slots in the decorative shell with the
bulb holder pins. Push the shell in and then twist
clockwise to lock. Repeat for other shell.
Shell Slot
❒ Push the rubber plug firmly into place.
❒ If a wet location junction box was not used, caulk
the wall plate mounting surface with silicone
weather sealant.
To avoid water damage and electrical shock,
keep bulb holders 30° below horizontal.
Gasket
Junction box ground wire to
green ground screw on fixture.
Mounting
Bolt
Keep bulbs at least
1" (25 mm) from the
Lock Nut
❒ Adjust the bulb holders by loosening the lock nuts but
do not rotate the bulb holders more than 180° from
the factory setting. When screwing in the floodlamps,
do not overtighten.
sensor. Do not allow
the bulbs to block
the lens.Lens
598-1094-04