Atlas DSP8807 Owner's Manual

Owner’s Manual DSP8807
Digital Processor
and Amplifier
DSP8807
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800.876.3333 • Fax: 800.765.3435
– 1 – AtlasSound.com
Specifications are subject to change without notice.
Digital Processor
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ATTENTION
RISQUE DE DECHARGE ELECTRIQUE
-NE PAS OUVRIR.
WARNING
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK
DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE.
CAUTION
´
and Amplifier
Table of Contents
Important Safety Instructions ......................................................................................................................................... 2
Introduction ..................................................................................................................................................................... 4
System Overview Flow Diagram ....................................................................................................................................6
Panel Layout ..................................................................................................................................................................... 8
Installation and Endpoint Termination ........................................................................................................................... 9
Software Installation and Setup ...................................................................................................................................14
Specifications ................................................................................................................................................................ 31
Troubleshooting Guide .................................................................................................................................................33
Warranty .........................................................................................................................................................................36
Important Safety Instructions
The lightning flash with arrowhead symbol within an equilateral triangle, is intended to alert the user to the presence of uninsulated “dangerous voltage “ within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
Owner’s ManualDSP8807
The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the product.
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this device near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other devices (including amplifiers) that produce heat.
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the device.
11. Only use attachments/accessories specified by the manufacturer.
12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the device. When a cart is used use caution when moving the cart/device combination to avoid injury from tip-over.
13. Unplug this device during lightning storms or when unused for long periods of time.
14. Refer all servicing to qualified service personnel. Servicing is required when the device has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled, or objects have fallen into the device, the device has been exposed to rain or moisture, does not operate normally, or has been dropped.
15. WARNING: To reduce the risk of fire or electric shock, this device should not be exposed to rain or moisture and objects filled with liquids, such as a vase, should not be placed on this device.
16. To completely disconnect this equipment from the mains, disconnect the power supply cord plug from the receptacle.
17. The mains plug of the power supply cord shall remain readily operable.
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800.876.3333 • Fax: 800.765.3435
AtlasSound.com – 2 –
Specifications are subject to change without notice.
Owner’s Manual DSP8807
CAUTION – When Installing the Product
Plugging in or unplugging the power cord with wet hands may result in electric shock.
Never move the device with the power cord plugged into the wall, as damage to the power cord may result.
When unplugging the cord from the wall, grasp the plug, NOT the cord.
Never install this device in humid or dusty locations, nor in direct sunlight, near sources of heat, or in areas where sooty smoke or
steam are present. Fire and electric shock may result.
Keep all sides of the device at least 31⁄2" away from objects that may obstruct air flow to prevent the unit's internal temperature rise.
WARNING – When the Device is in Use
• To prevent electric shock, do not remove the device cover as there are high voltage components inside. Refer all servicing to Atlas Sound.
• Should any of the following irregularities occur during use, immediately switch off the power, disconnect the power cord from the
AC outlet and contact Atlas Sound. Do not to attempt to continue operation with the device as this may cause fire or electric shock:
Smoke or strange smell coming from the unit.
If the device falls or the case is damaged.
If water or any metallic objects falls into the device.
If the power supply cord is damaged in any way.
If the device is malfunctioning.
Do not insert or drop metallic objects or flammable materials into the ventilation holes of the device's cover,
as this may result in electric shock or fire.
Do not place any containers with liquid or metallic objects on the top of the device. If any liquid spills into the unit, fire or electric shock may result.
Never operate this device or touch the power supply cord during an electrical storm, electric shock may result.
Never exceed the wattage on the product when connecting equipment. Fire and/or property damage may result.
Operate the device only with the voltage specified on the unit. Fire and/or electric shock may result if a higher
voltage is used.
Do not modify, kink, or cut the power cord. Do not place the power cord in close proximity to heaters and do not place heavy objects on the power cord, including the device itself, doing so may result in fire or electrical shock.
Ensure that the safety ground terminal is connected to a proper ground. Never connect the ground to a gas pipe as a catastrophic disaster may result.
• Be sure the installation of the product is stable, avoid slanted surfaces as the product may fall and cause injury or property damage.
and Amplifier
Digital Processor
CAUTION – When the Device is in Use
Never place heavy objects on the product, causing it to fall and/or break, resulting in personal injury and property damage. In addition, the product itself may fall and cause injury and property damage.
Contact Atlas Sound for instructions on cleaning the inside of the unit. Large accumulations of dust inside the unit may result in heat buildup and fire.
Ensure that the power supply plug is securely plugged into the wall outlet. Never allow dust to accumulate on the power plug or inside the wall outlet.
When cleaning the unit or the unit is not to be operated for an extended time period, unplug power cord from the wall.
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800.876.3333 • Fax: 800.765.3435
– 3 – AtlasSound.com
Specifications are subject to change without notice.
Digital Processor
and Amplifier
Introduction
The Atlas Sound DSP8807 digital processor “Privacy” system is a self contained, compact multi-zone digital DSP-GUI controlled processor and digital amplifier capable of simultaneous distribution of masking, paging, and background music signals for usemaybe in Industrial,
Institutional, Commercial and Government facilities.
The Atlas Sound DSP8807 unit is capable of automatic mixing, set up and administration of all 8x8 inputs / outputs per zone (channel) via an intuitive ‘simple to use’ Graphic User Interface (GUI) managed via a local Windows® based laptop or desktop computer. The DSP8807 has 8 channels of independent on-board digital class-D amplifiers that are capable of delivering 50W RMS at 70V output. Additionally a simultaneous audio line level output rated at 1V/600Ω (nominal) per zone is available for driving higher power amplifiers. The DSP8807 also has two (2) independent uncorrelated pink noise generators which are random and non-repeating up to 215 hours with EQ adjustments programmable on a per zone basis. The DSP8807 provides dynamic control and management based on
IEEE802.1 AVB standards (Audio-Video Bridging) with independent Linkwitz-Riley at 24dB) and Parametric EQ for calibration of all PA, ambient level sensing and automatic level control on a per zone basis. Paging (PA) presets can be assigned in 10dB increments (10, 20, 30dB) per zone with automatic gain control (AGC) for all Telco
and microphone paging inputs.
The DSP8807 GUI is called the ‘Sound Media Interface’. The software has the ability to expand up to (256) systems with over 2,000 zones (2,048) with primary and secondary assignment in a zone paging dialing plan. It also provides the ability to set up All zone page, Group zone page (up to 32 groups) and Single zone page with an architectural dialing plan (2-digit DTMF) set up in the GUI. Each DSP8807 is capable of managing remote ambient level sensing microphones (ALM-1) for each zone (x8) wired via a single CAT5e cable up to 1,000 feet from the DSP8807 for automatic adjustment of the masking level based on real-time noise levels with set up and control via the GUI.
1
3 Octave (28) band EQ *(Filter type is Butterworth @ 19dB and
Owner’s ManualDSP8807
The Atlas Sound DSP8807 system provides the following basic masking capabilities:
• Creates an acceptable level of speech privacy in open work areas
• Enhances speech privacy between modular offices
• Decreases intelligibility and noise distraction caused by stand-up, casual conversations and random room noises
• Reduces awareness of existing sounds
• Increases worker productivity and employee satisfaction
• Enhances clients revenue due to less employee distraction
• Lessens the need for unexpected and expensive acoustical upgrades
• Flexibility which insures specific masking spectrums for varying ceiling types including; t-bar, open, wood slats and clouds
Basic Function
• (8) Channels of Random Pink Noise Generator Non-Repeating Up to 215 Hours
• (8) Audio Outputs of 50W RMS Digital Class-D Amplification at 85% Efficiency
• (8) Audio Line Outputs at 1V/600Ω (Nominal) for Unlimited Power Per Zone
• (8) Independent Outputs of 1⁄3 Octave 28-Band EQ Defined and Shaped in GUI
• IEEE 802.1 AVB (Audio Video Bridging) Technology for Time Aligned Networking of Multiple Units
• AVB Operation Allows IP Based Paging Via Ethernet Connection
• (8) Ambient Sensing Microphone Inputs (RJ45) for Automatic Level Sensing (6dB) and Control
• Compatible with ALM-1 Ambient Sensing Microphones Operating Up to 1,000 Feet Away
• Multiple Audio Source Inputs for Background Music, Paging and Emergency Page Overrides
• Telco Paging Input (Loop Start) with 2 to 5 Digit DTMF (Touch Tone) Dial Plan Defined in GUI
• Multiple ‘Form-C’ Contact Closure Relay Inputs (x4) for Ancillary Devices
• Microphone Input with System Mute
• Emergency Override Inputs for Automatic Page Override
• On-Board MAC Address for IP Addressability and Remote Control Compatible With DHCP MS Server
• User Friendly GUI (Sound Media Interface) for Set Up
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800.876.3333 • Fax: 800.765.3435
AtlasSound.com – 4 –
Specifications are subject to change without notice.
Owner’s Manual DSP8807
• Zone Expansion from 1 to 2,048 Via Standard CAT5e – CAT6 Cabling (Up to 256 Systems)
• All-Call Page, Group Zone Page, and Single Zone Page Defined in GUI
• Independent Parametric EQ for All Paging Sources
• Microphone Balanced Input with On-Board Phantom Power at 32VDC
• On Board Signal Generators for Paging Confirmation, Busy, and Pre-Announce Tones
• Non-Volatile DSP Memory Components for All System Controls with Ten (10) Year Memory
• DSP8807 Multiple Mounting Options; Rack, Cabinet, Shelf, or Wall at 2RU (3.5") Height x 15" Deep
• Visual Status Front Multicolor LEDs for All Major Inputs and Outputs
• Rear Access Network Connection (RJ45) with Front Manual DSP Reset Button
• Overload, Short, and Current Limit Protection with Automatic Reset for All Critical Components
• All Power Components Are UL Recognized, Boards Are UL94v0 and RoHS
• DSP8807 Is UL / CUL / FCC and CB (International) Listed
BASIC APPLICATIONS DIAGRAM
Client telephone system for
localized or campus wide paging.
Music source for zone
selected playback.
IP switch connecting multiple Atlas
Sound units for AVB (Audio Visual
Bridging) and network access.
and Amplifier
Digital Processor
Microphone connection for paging
and campus wide
IP addressable for over
network system control.
Capable of simultaneously
distributing paging and music.
distributing sound masking, paging,
Ambient sensing microphone controlling
sound masking volume in a densely occu-
pied zone.
notications.
Capable of simultaneously
and music.
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800.876.3333 • Fax: 800.765.3435
– 5 – AtlasSound.com
Specifications are subject to change without notice.
Digital Processor
Limiter
Bass-Treble
Para - EQ
Mic
Limiter
Bass-Treble
Para - EQ
Bass-Treble
Bass-Treble
Noise 1
Filter
Line 1
Bass-Treble
Page Matrix Array
EAO
Override
Graphic EQ
Graphic EQ
Graphic EQ
Graphic EQ
Graphic EQ
Graphic EQ
Masking Matrix Array
D-A
Zone Amp 1
D-A
Line Out 1
Mic
Telco
A-D
Music 1
Music 2
Line 1
Lynx
SMS
Processors
Rear
Phy
Phy
Lynx
SMS
Mic CC
EAO CC Restart
Line 2
A-D
Lynx
SMS
Amb 5
Amb 6
Amb 7
Amb 8
Amb 1
Amb 2
Amb 3
Line 2
Bass-Treble
Line 2 CC
D-A
Zone Amp 2
D-A
Line Out 2
D-A
Zone Amp 3
D-A
Line Out 3
D-A
Zone Amp 4
D-A
Line Out 4
D-A
Zone Amp 5
D-A
Line Out 5
D-A
Zone Amp 6
D-A
Line Out 6
D-A
Zone Amp 7
D-A
Line Out 7
D-A
Zone Amp 8
D-A
Line Out 8
Bass-Treble
Para - EQ
High Pass
High Pass
High Pass
High Pass
High Pass
High Pass
High Pass
High Pass
Amp O/P PCB
and Amplifier
SYSTEM OVERVIEW – SIGNAL FLOW DIAGRAM
I/O Processing
Line 1 CC
A-D
AVIO Core
Signal
Processor
DTMF
Receiver
Front Control RJ45
Control RJ45
AVB Core
Network
Processors
Amb 4
Ambient
Mic
Processor
System Functional Diagram
DSP8807 Project
Preliminary
March 24
th
, 2010
Rev 1.2
Network Page
Telco
Music 1
Music 2
DSP Block
Owner’s ManualDSP8807
Graphic EQ
Filter Noise 2
Graphic EQ
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
AtlasSound.com – 6 –
Specifications are subject to change without notice.
Telephone: 800.876.3333 • Fax: 800.765.3435
Owner’s Manual DSP8807
D-A
Zone Amp 1
D-A
Line Out 1
D-A
Line Out 2
D-A
Zone Amp 3
Line Out 3
D-A
Zone Amp 4
D-A
Line Out 4
Zone Amp 5
D-A
Zone Amp 6
D-A
Line Out 6
D-A
Line Out 7
D-A
Zone Amp 8
Line Out 8
High Pass
High Pass
High Pass
High Pass
High Pass
High Pass
Digital Processor
and Amplifier
EAO
Override
High Pass
High Pass
Amp O/P PCB
D-A
D-A
Zone Amp 2
D-A
D-A
D-A
D-A
Line Out 5
Zone Amp 7
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800.876.3333 • Fax: 800.765.3435
– 7 – AtlasSound.com
Specifications are subject to change without notice.
17.1"
3.5"
DSP8807 FRONT
DSP8807 REAR
Digital Processor
and Amplifier
19.0"
Owner’s ManualDSP8807
DSP8807 TOP PANEL
DSP8807 Top Panel: Important notifications and MAC Address screened on top
MAC Address / (2) locations
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800.876.3333 • Fax: 800.765.3435
AtlasSound.com – 8 –
Specifications are subject to change without notice.
Owner’s Manual DSP8807
INSTALLATION
COMPUTER NETWORK TERMINATION
Digital Processor
and Amplifier
NOTE: All ‘RJ45’ Network connections must be wired to meet EIA/TIA 568B standard.
256
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800.876.3333 • Fax: 800.765.3435
– 9 – AtlasSound.com
Specifications are subject to change without notice.
Digital Processor
and Amplifier
70V SPEAKER TERMINATION
Dockable 2-pin/socket connectors (commonly referred to as ‘Phoenix’ type) are used which are keyed or polarized to fit one way – do
not force fit these connectors and follow these basic instructions;
• Do NOT force fit the connectors – they are polarized to fit in one direction
• Follow the +/- wiring polarity to all speakers
• Use only 70V speakers
• Ensure that total speaker wattage taps per channel does NOT EXCEED 80% of the rated output of 50W RMS per zone.
SPEAKER OUTPUTS (70V)
ZONE 1
+ + + +
ZONE 2
ZONE 3 ZONE 4
Owner’s ManualDSP8807
+
50W RMS / ZONE
70V SPEAKERS
+
AUDIO LINE LEVEL TERMINATION (1V/600Ω)
Typical use of the Audio Line Output is to increase the power (Watts) via an auxiliary amplifier capable of powering speakers above the
50W RMS level provided by DSP8807. Ensure the wiring matches the (+ / - / G) for each zone output to each amplifier audio input.
LINE OUTPUTS (1V / 600 OHM)
+
+
AUXILIARY AMPLIFIER
(ADDED POWER)
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800.876.3333 • Fax: 800.765.3435
AtlasSound.com – 10 –
Specifications are subject to change without notice.
Owner’s Manual DSP8807
AC POWER INPUT (120VAC @ 60Hz or 240VAC @ 50Hz)
As noted in the ‘important notices’ section the DSP8807 utilizes a UL recognized IEC AC power plug and cord (provided with the unit)
which must not be changed or defeated. Please follow these important instructions. Failure to do so will void the product warranties.
The Mains Plug is the main disconnect device for the product, and shall be located so as to be readily accessible.
NOTE: Once the AC power is switched ‘ON’ it will take approximately ‘30’ seconds to initialize and start up.
• Do not defeat the safety purpose of polarized, keyed or grounding type connectors. A polarized plug has two (or multiple) contacts
with one wider or longer than the other. A grounding type plug has two blades and a third grounding plug. The wide blade or third
prongs are provided for your safety. Do not defeat or change these. If the provided IEC power plug does not fit into your outlet,
consult an electrician or your local authority having jurisdiction to replace the outlet to ensure meeting local building codes while
assuring proper connection.
• Protect the power cord from being walked on or pinched particularly at the plug, receptacle outlet, and the exit point of the unit.
AC POWER IN
Replace AC Fuse with UL recognized 2A @ 250VAC or 5A @ 110VAC
AC cable with IEC plug provided. All
120VAC
Power
wiring to meet NEC/ UL code
120V operation: T 8A L 250V 240V operation: T 5A L 250V
Fuse
and Amplifier
Typical view of
UL rated Fuse
Digital Processor
AMBIENT SENSING MICROPHONE (ALM-1) TERMINATION
Typical Ceiling Grid Installation
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800.876.3333 • Fax: 800.765.3435
– 11 – AtlasSound.com
Specifications are subject to change without notice.
Loading...