Questo prodotto è coperto da garanzia Atlantis Land On-Site della durata
di 3 anni. Per maggiori dettagli in merito o per accedere alla
documentazione completa in Italiano fare riferimento al sito www.atlantis-
land.com.
ENGLISH
This product is covered by Atlantis Land 3 years On-Site warranty. For
more detailed informations please refer to the web site www.atlantis-land.com.
For more detailed instructions on configuring and using this device, please
refer to the online manual.
FRANCAIS
Ce produit est couvert par une garantie Atlantis Land On-Site de 3 ans.
Pour des informations plus détaillées, référez-vous svp au site Web
www.atlantis-land.com.
DEUTSCH
Dieses Produkt ist durch die Atlantis Land 3 Jahre On-Site Garantie
gedeckt. Für weitere Informationen, beziehen Sie sich bitte auf Web Site
www.atlantis-land.com.
ESPAÑOL
Este producto està cubierto de garantía Atlantis Land On-Site por 3 años.
Para una información más detallada, se refiera por favor al Web site
www.atlantis-land.com.
Where solutions begin
Company certified ISO 9001:2000
Page 3
Where solutions begin
Company certified ISO 9001:2000
Page 4
OnePower UPS 700VA/300W
ITALIANO
1.1 Introduzione al prodotto 3
1.2 Verifica Iniziale 3
1.3 Contenuto della confezione 3
1.4 Collocazione 4
1.6 Test di Funzionamento 6
1.7 Pannello frontale 6
1.8 Le porte posteriori 8
1.9 Sostituzione Batterie 8
APPENDICE A: RISOLUZIONE DEI PROBLEMI 10
A.1.1 Problematiche dell’UPS 10
A.1.2 Batterie e Fusibile 11
APPENDICE B: SUPPORTO OFFERTO 12
ENGLISH
1.1 Important Safety Instructions 15
1.2 Inspection 15
1.3 Package Contents 15
1.4 Placement 16
1.6 Operation Test 18
1.7 Front Panel Explanations 18
1.8 Rear Panel Explanations 20
1.9 Replacing the Battery 20
APPENDIX A: TROUBLE SHOOTING 22
A.1.1 UPS 22
A.1.2 Battery and Fuse 23
APPENDIX B: SUPPORT 24
Page 5
OnePower UPS 700VA/300W
FRANCAIS
1.1 Introduction 28
1.2 Vérification 28
1.3 Dans la boîte 28
1.4 Mise en place 29
1.7 Facade 31
1.8 Face arrière 32
1.9 Changement de Batterie 32
APPENDICE A: PROBLEMES 34
A.1.1 Problèmes 34
A.1.2 Batterie et Fusible 35
APPENDICE B: ASSISTANCE 36
TECHNICAL FEATURES 37
BACKUP TIME 38
A03-PE702_MX01 (V1.0 July 2006)
Page 6
OnePower UPS 700VA/300W(IT)
AVVERTENZE
Abbiamo fatto di tutto al fine di evitare che nel testo, nelle immagini e nelle tabelle
presenti in questo manuale, nel software e nell'hardware fossero presenti degli
errori. Tuttavia, non possiamo garantire che non siano presenti errori e/o
omissioni. Infine, non possiamo essere ritenuti responsabili per qualsiasi perdita,
danno o incomprensione compiuti direttamente o indirettamente, come risulta
dall'utilizzo del manuale, software e/o hardware.
Il contenuto di questo manuale è fornito esclusivamente per uso informale, è
soggetto a cambiamenti senza preavviso (a tal fine si invita a consultare il sito
www.atlantisland.it o www.atlantis-land.com per reperirne gli aggiornamenti) e
non deve essere interpretato come un impegno da parte di Atlantis Land spa che
non si assume responsabilità per qualsiasi errore o inesattezza che possa
apparire in questo manuale. Nessuna parte di questa pubblicazione può essere
riprodotta o trasmessa in altra forma o con qualsiasi mezzo, elettronicamente o
meccanicamente, comprese fotocopie, riproduzioni, o registrazioni in un sistema
di salvataggio, oppure tradotti in altra lingua e in altra forma senza un espresso
permesso scritto da parte di Atlantis Land spa. Tutti i nomi di produttori e dei
prodotti e qualsiasi marchio, registrato o meno, menzionati in questo manuale
sono usati al solo scopo identificativo e rimangono proprietà esclusiva dei loro
rispettivi proprietari.
CE Mark Warning
Questo dispositivo appartiene alla classe B. In un ambiente domestico il
dispositivo può causare interferenze radio, in questo caso è opportuno prendere
le adeguate contromisure.
FCC
Questo dispositivo è stato collaudato ed è risultato conforme ai limiti previsti per i
dispositivi digitali di Classe B, ai sensi della Parte 15 della normativa FCC. Tali
limiti sono concepiti per fornire un grado di protezione ragionevole contro le
interferenze dannose in ambienti residenziali. Questo dispositivo genera, utilizza
e può emettere radiofrequenze e, qualora non installato e utilizzato in conformità
alle istruzioni, può provocare interferenze dannose alle comunicazioni radio.
Tuttavia non esiste garanzia che una particolare installazione non provochi
interferenza. Se il dispositivo causa interferenze dannose alla ricezione
radiotelevisiva (il che può essere verificato spegnendo e accendendo il
dispositivo), si consiglia all’utente di adottare una o più delle seguenti misure
onde correggere l’interferenza:
-Riorientare o riposizionare l’antenna di ricezione
-Aumentare la separazione tra i dispositivi
A03-PE702 Pag. 1
Page 7
OnePower UPS 700VA/300W(IT)
-Collegare il dispositivo a una presa di alimentazione diversa da quella del
ricevitore
-Rivolgersi a un rivenditore o a un tecnico radiotelevisivo qualificato per
l’assistenza
ATTENZIONE!
E’ opportuno leggere attentamente questo manuale prima dell’installazione e
della messa in servizio del gruppo di continuità Atlantis Land. La garanzia decade
se non vengono rispettate tutte le norme e le prescrizioni indicate nel presente
manuale operativo.
L’UPS può essere riparato solo da personale qualificato.
La garanzia della batteria è di 1 anno a partire dalla data di acquisto.
Qualora venga sostituita la batteria seguire le seguenti precauzioni:
• non indossare orologi, anelli o oggetti di metallo;
• impugnare attrezzi con materiale isolante;
• indossare guanti di gomma e stivali;
• non appoggiare attrezzi o parti di metallo sopra la batteria;
All’uscita dell’UPS può esserci una tensione di 220V anche quando il gruppo è
scollegato dalla rete. Non aprire mai il coperchio.
Non introdurre mai liquidi di nessun genere all’interno della macchina.
Attenzione: per garantire l’integrità ed il corretto funzionamento del gruppo di
continuità, non collegare mai all’uscita dell’UPS fotocopiatrici, stampanti laser,
utensili elettrici o qualsiasi altro tipo di carico induttivo.Tale prodotto è stato
progettato per essere collegato esclusivamente a personal computer. Il non
rispetto di queste indicazioni porterà all’immediato decadimento della garanzia.
Attenzione: Al fine di evitare rischi di incendi o shock elettrici, disporre l’apparato
in ambiente indoor con temperatura ed umidità controllate e privo di agenti
conduttori di ogni genere.
Attenzione: La principale precauzione da osservare è quella di spegnere il
gruppo se, per pause lavorative o festive, viene disinserita la rete di
alimentazione principale, per evitare la scarica totale delle batterie (situazione di
black-out prolungato). Lasciare caricare l’UPS per almeno 8 ore, ogni 3 mesi, in
caso sia scollegato dalla rete elettrica (condizioni ambientali non standard
possono accelerare lo scarico delle batterie).
Attenzione: Non rimuovere i pannelli esterni al fine di evitare il rischio di shock
elettrico. Per ogni dubbio o perplessità rivolgersi a personale qualificato.
Attenzione: Nell’UPS è installata una batteria di accumulatori che è fonte di
energia, per cui all’interno del gruppo vi sono delle tensioni pericolose presenti
anche a gruppo spento e/o scollegato dalle rete elettrica.
Attenzione: Al fine di prevenire il danneggiamento è opportuno non
sovraccaricare ma i l’UPS (max 300 W).
A03-PE702 Pag. 2
Page 8
OnePower UPS 700VA/300W(IT)
1.1 Introduzione al prodotto
Seguire attentamente tutte le istruzioni durante l’installazione. Leggere
attentamente l’intero manuale prima di iniziare l’installazione del dispositivo.
1.2 Verifica Iniziale
Controllare immediatamente il dispositivo. Rivolgersi al rivenditore qualora il
dispositivo fosse danneggiato. La confezione in cartone è in materiale riciclabile e
andrebbe conservata e utilizzata per proteggere il prodotto durante eventuali
spedizioni.
1.3 Contenuto della confezione
Una volta aperta la confezione in cartone dovrebbero essere presenti i seguenti
componenti:
OnePower UPS 700VA/300W
2 cavi IEC
Fusibile di scorta (4A/250Vac)
Manuale di installazione multilingua
Tagliando di Garanzia
Qualora mancasse uno qualsiasi di questi componenti rivolgersi immediatamente
al rivenditore.
A03-PE702 Pag. 3
Page 9
OnePower UPS 700VA/300W(IT)
1.4 Collocazione
Al fine di evitare rischi di incendi o shock elettrici, disporre l’apparato in ambiente
indoor con temperatura ed umidità controllate e privo di agenti conduttori di ogni
genere. Si ricorda inoltre che:
• L’UPS è da usarsi esclusivamente in ambienti chiusi (indoor)
• Deve essere collocato lontano da qualsiasi fonte di calore
• Non deve essere esposto direttamente ai raggi solari
• Deve essere collocato in ambienti con umidità controllata
• E’ opportuno lasciare almeno 15 cm dalle feritoie al fine di consentire
un’opportuna areazione
1.5 Connessione al Carico
Anzitutto collegare il cavo di alimentazione alla presa di ingresso rete posta sul
retro dell’UPS ed inserire la spina nella rete. Successivamente collegare il
carico alle uscite poste nel retro dell’UPS. Sono disponibili 3 prese IEC in
modalità Backup (in caso di black-out sono alimentate). Accendere l’UPS dopo
che tutti i carichi sono stati già accesi.
A03-PE702 Pag. 4
Page 10
OnePower UPS 700VA/300W(IT)
Attenzione: Per garantire l’integrità ed il corretto funzionamento del gruppo di
continuità, non collegare mai all’uscita dell’UPS fotocopiatrici, stampanti laser,
utensili elettrici o qualsiasi altro tipo di carico induttivo.
E’ possibile vedere in figura un esempio di cablaggio completo.
A03-PE702 Pag. 5
Page 11
OnePower UPS 700VA/300W(IT)
1.6 Test di Funzionamento
1. Collegare l’UPS alla rete elettrica.
2. Tenere premuto pulsante di accensione (immediatamente il LED line si
accenderà di verde) sino a che il LED non si spegne (a questo punto è
possibile rilasciare il bottone). Dopo qualche secondo (terminata la fase di
autotest) il LED Line (
3. Una volta collegato il carico all’UPS è possibile effettuare un test di
corretto funzionamento. A tal fine rimuovere il cavo che collega l’UPS alla
rete elettrica. Il Led Line (
simultaneamente partirà un beep acustico (ogni 2 secondi).
4. L’intervento dell’UPS permette al PC di continuare ad avere la continuità
elettrica. A questo punto riconnettere l’UPS alla linea elettrica.
ATTENZIONE: dopo l’avviamento iniziale, tenere alimentato il gruppo per almeno
10 ore, affinché le batterie possano caricarsi completamente. A questo punto sarà
possibile simulare un BLACK-OUT.
ATTENZIONE: per spegnere l’UPS è sufficiente tenere premuto il pulsante di
accensione ed attendere che il LED Line sia spento.
) si accenderà di verde.
) inizierà a lampeggiare ogni 2 secondi,
1.7 Pannello frontale
Sul pannello frontale dell’apparato è presente un Led che indica lo stato di
funzionamento.
A03-PE702 Pag. 6
Page 12
OnePower UPS 700VA/300W(IT)
LED/Bottone Informazione
Main Switch ()
LED Line ()
Per accendere/spegnere l’UPS quando la rete elettrica è
presente.
Accensione: tenere premuto per circa 3 secondi sino a
che il LED Line non si spegne, quindi rilasciare il
bottone di accensione (a questo punto, dopo la fase di
autotest, l’UPS sarà operativo).
Per accendere l’UPS in caso manchi la rete elettrica ed
alimentare direttamente il carico. Questa funzionalità
“DC-Start” richiede che il carico collegato sia inferiore
all’80% del carico massimo (è importante accendere
prima tutte le periferiche e per ultimo l’UPS. Il carico
infatti deve restare costante).
Acceso verde fisso quando il dispositivo è acceso e
l’alimentazione di rete è presente.
Lampeggiante (ogni 2 secondi) quando l’alimentazione
di rete è assente. Contemporaneamente il dispositivo
emette un beep sonoro intermittente (sempre ogni 2
secondi).
Lampeggiante (2 volte al secondo) quandoil livello della
batteria è critico. Contemporaneamente il dispositivo
emette un beep sonoro intermittente (sempre 2 volte al
secondo).
Spento, quando la carica della batteria è prossima
all’esaurimento (al fine di proteggere da un eccessivo
scaricamento della batteria). A questo punto lasciare
l’UPS collegato alla rete elettrica per 8 ore.
A03-PE702 Pag. 7
Page 13
OnePower UPS 700VA/300W(IT)
1.8 Le porte posteriori
Identificativo Utilizzo
1
2
3
Connettore di ingresso per la rete elettrica.
Prese IEC di back-up. Collegare a queste prese gli apparati
che devono essere alimentati dalla batteria in caso di blackout o altre anomalie sulla rete elettrica.
Fusibile di protezione (4A/250Vac).
Sticker contenente i valori di targa dell’apparato.
1.9 Sostituzione Batterie
La batteria dell’UPS ha 1 anno di garanzia.
Qualora venga sostituita la batteria seguire le seguenti precauzioni:
• non indossare orologi, anelli o oggetti di metallo
• impugnare attrezzi con materiale isolante
• indossare guanti di gomma e stivali
• non appoggiare attrezzi o parti di metallo sopra la batteria
All’uscita dell’UPS può esserci una tensione di 220V anche quando il gruppo è
scollegato dalla rete.
A03-PE702 Pag. 8
Page 14
OnePower UPS 700VA/300W(IT)
Prima di iniziare la sostituzione della batteria è opportuno spegnere l’UPS e
staccarlo dalla rete elettrica.
1. Utilizzare un cacciavite a stella per rimuovere le 2 viti poste nella parte
inferiore del pannello frontale. Aprire delicatamente il dispositivo.
2. Sfilare delicatamente la batteria.
3. Staccare il filo di colore nero (negativo) e poi quello di colore rosso
(positivo).
4. Connettere i cavi alle nuove batterie (è normale osservare delle scintille
presso i connettori della batteria).
5. Spingere delicatamente le batterie nell’UPS.
6. Riposizionare il pannello superiore ed infine riavvitare le 2 viti.
7. Riporre la batteria sostituita in un luogo appropriato.
ATTENZIONE: Una volta sconnessa la batteria, il carico non viene protetto in
caso mancasse l’alimentazione di rete.
A03-PE702 Pag. 9
Page 15
OnePower UPS 700VA/300W(IT)
APPENDICE A: Risoluzione dei problemi
Questo capitolo illustra come identificare e risolvere eventuali problemi riscontrati
con l’utilizzo del dispositivo.
A.1.1 Problematiche dell’UPS
I LEDs ed i segnali acustici sono un utile strumento per individuare eventuali
problemi, osservandone lo stato e/o ascoltandone il tipo di beep è possibile
individuare velocemente un eventuale malfunzionamento.
Situazione Controllo Soluzione
L’Alimentazione
elettrica è
presente ma il
LED Line () non
è acceso.
Il LED Line ()
lampeggia 2 volte
al secondo (con
segnale acustico)
senza che ci sia
tensione in uscita.
L’UPS si spegne
quando manca la
rete elettrica.
1. Accertarsi che l’UPS sia
acceso (premere il
bottone di Main Switch
per 3 secondi).
2. Il Fusibile è funzionante?
3. Controllare il cavo di
alimentazione.
1. Il voltaggio delle batterie
è troppo basso.
1. Controllare il carico
verificando di non essere
in condizioni di overload.
2. Controllare se la batteria
è guasta.
1. Accendere l’UPS
premendo il bottone di
Main Switch.
2. Cambiare il fusibile.
3. Cambiare il cavo di
alimentazione o
controllare che sia
propriamente collegato.
1.
Ricaricare l’UPS per
almeno 24 ore.
1. Sconnettere parte del
carico.
2. Cambiare la batteria.
Nonè possibile
accendere il
dispositivo.
Nessun LED si
accende nel
pannello frontale.
1. Schiacciare per più di 3
secondi il pulsante di
Switch (On/Off) sino a
che il LED Utilità si
spegne. A questo punto
l’UPS dovrebbe avviarsi.
A03-PE702 Pag. 10
1. Riprovare seguendo le
istruzioni attentamente.
1. Lasciare il prodotto sotto
carica per 24 ore e
riprovare.
Page 16
La durata delle
1. Le batterie non sono
OnePower UPS 700VA/300W(IT)
2. Chiamare l’assistenza
tecnica di Atlantis Land.
1. Ricaricare l’UPS per 10 ore.
batteria non è
soddisfacente.
L’UPS si accende
ma non è in grado
di funzionare in
modalità normale.
completamente cariche.
2. Le batterie sono vicine al
termine del loro ciclo di
vita.
1. Controllare la presenza di
rete elettrica.
A.1.2 Batterie e Fusibile
Domanda Risposta
Cos’è il
Backup time?
E’ la durata cui l’UPS può mantenere attivo il carico ad esso
collegato prima che le batterie siano completamente scariche.
Tale durata, ovviamente, dipende dal tipo di carico. Controllare
nella sezione alle fine del manuale.
2. Rimpiazzare le batterie
(come da punto 1.9).
1. Una volta accertato che la
rete elettrica è funzionante,
ricollegare prima l’UPS e
poi riaccenderlo.
Che tipo di
batterie sono
incluse
nell’UPS?
Ogni quanto
vanno
cambiate?
Dove posso
trovare le
batterie per la
sostituzione?
Come verifico
lo stato del
fusibile?
Quali sono le
La batteria utilizzata è 12VDC- 7A/h.
Dipende dal tipo di utilizzo. E’ buona norma testare
periodicamente l’UPS per controllare lo stato di deterioramento
delle batterie.
Si raccomanda di sostituire le batterie una volta all’anno.
1. Un qualunque negozio specializzato.
2. Chiederle direttamente all’assistenza tecnica di Atlantis Land.
Staccare innanzitutto il prodotto dalla rete elettrica e sfilare
delicatamente l’alloggio portafusibile (identificativo N° 3,
paragrafo 1.8). Rimuovere il fusibile e controllare l’integrità del
filamento interno. Laddove questo fosse rotto, sostituirlo col
fusibile di scorta.
Nell’alloggio portafusibile è contenuto un fusibile di scorta. Le
A03-PE702 Pag. 11
Page 17
OnePower UPS 700VA/300W(IT)
specifiche del
Fusibile?
Le batterie
consentono
una durata
non in linea
con quanto
riportato nella
tabella
(Backup
Time).
caratteristiche sono: 4A, 250Vac.
1. Le condizioni ambientali possono alterare sensibilmente tali
valori.
2. Andrebbero effettuati almeno 5 cicli di carica/scarica prima
di arrivare ad un uso ottimale.
3. L’UPS integra un circuito di controllo che evita di scaricare
completamente la batteria.
4. Dopo un anno prendere in considerazione l’idea di sostituire
la batterie prossime all’esaurimento.
APPENDICE B: Supporto Offerto
Per ogni problema con l’UPS consultare questo manuale. Molti problemi
potrebbero essere risolti cercando la soluzione del problema nell’APPENDICE A.
Per qualunque altro problema o dubbio è possibile contattare l’help desk
telefonico (02/93907634) gratuito di Atlantis Land (munirsi di serial number e
codice prodotto presente sul retro dell’ups) che fornirà assistenza da lunedì al
giovedì dalle 9:00 alle 13:00 e dalle 14:00 alle 18:00. Il venerdì dalle 9 :00 alle
13 :00. E’ possibile anche utilizzare il fax (02/93906161) la posta elettronica
Atlantis Land SpA
Viale De Gasperi 122
20017 Mazzo di Rho(MI)
Tel: 02/93907634(help desk)
Fax: 02/93906161
Email: info@atlantis-land.com
nell’oggetto il codice del prodotto di cui si chiede assistenza)
WWW: http://www.atlantisland.it
oppure tecnici@atlantis-land.com (mettere
o www.atlantis-land.com
A03-PE702 Pag. 12
Page 18
OnePower UPS 700VA/300W(EN)
Copyright
The Atlantis Land logo is a registered trademark of Atlantis Land SpA. All other
names mentioned mat be trademarks or registered trademarks of their respective
owners. Subject to change without notice. No liability for technical errors and/or
omissions.
CE Mark Warning
This is a Class B product. In a domestic environment, this product may cause
radio interference, in which case the user may be required to take adequate
measures.
FCC Information
This equipment has been tested and found to comply with the limits for a Class B
device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential
installation, This equipment generates, uses and can radiate radio frequency
energy and if not installed and used in accordance with the instructions may
cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be checked by switching the equipment off and
on, the user should correct the interference by one or more of the following
measures.
• Move the receiving antenna to a different position.
• Move the equipment and receiver apart.
• Connect the equipment into an outlet on a different circuit.
• Consult the dealer or an experienced radio/TV technician for help.
IMPORTANT SAFETY INSTRUCTIONS
This manual contains important safety instructions. Please follow all instructions
carefully during installation. Read this manual thoroughly before attempting to
unpack, install or operate.
Caution: Any changes or modifications to the equipment not expressly approved
by the party responsible for compliance could void the user’s authority to operate
the equipment.
Shielded interface cables and AC power cords, if any, must be used in order to
comply with the emission limits.
Caution: To prevent the risk of fire or electric shock, install in a temperature and
humidity controlled indoor area, free of conductive contaminants.
Caution: Risk of electric shock, do not remove the cover. No user serviceable
parts. Refer servicing to qualified service personnel.
A03-PE702 Pag. 13
Page 19
OnePower UPS 700VA/300W(EN)
Caution: Risk of electric shock, hazardous live parts inside this UPS can be
energized from the battery supply even when the input AC power is disconnected.
Caution: Risk of electric shock, Battery Circuit is not isolated from AC input,
hazardous voltage may exist between battery terminals and ground. Test before
touching.
Caution: The UPS is designed to be for use with computer loads only. Do not
connect a laser printer to the outlets
Caution: Do not try to repair the unit yourself, contact your local supplier or your
warranty will be void.
Caution: To avoid the UPS from damage, please do not overload it (max. 300W).
.
A03-PE702 Pag. 14
Page 20
OnePower UPS 700VA/300W(EN)
1.1 Important Safety Instructions
This manual contains important safety instructions. Please follow all instructions
carefully during installation. Read this manual thoroughly before attempting to
unpack, install or operate.
1.2 Inspection
Inspect the UPS upon receipt. Notify the carrier and dealer if there is damage.
The package is recyclable; save it for reuse or dispose of it properly.
If any of the above items are missing, please contact your reseller.
A03-PE702 Pag. 15
Page 21
OnePower UPS 700VA/300W(EN)
1.4 Placement
To prevent the risk of fire or electric shock, install in a temperature and humidity
controlled indoor area, free of conductive contaminants.
• This UPS system is designed for indoor use only.
• Do not install the UPS under direct sunlight. Your warranty will be void if
the batteries fail due to overheating.
• Install in a temperature and humidity controlled indoor area
• To eliminate any overheating of the UPS, keep all ventilation openings
free from obstruction and do not place any foreign objects on top of the
UPS. Keep the UPS 15 cm away from the wall.
1.5 Connect the loads
First, connect the UPS with the AC Mains, then plug the loads into the output
connectors on the rear of the UPS. To use the UPS as a master “On/Off” switch,
make sure that all of the loads are switch “On”.
A03-PE702 Pag. 16
Page 22
OnePower UPS 700VA/300W(EN)
Caution: Do not connect a laser printer to the outlets. These UPS outlets
provide battery power and surge protection to the equipment when utility voltage
is outside acceptable limits.
A03-PE702 Pag. 17
Page 23
OnePower UPS 700VA/300W(EN)
1.6 Operation Test
1. Connect the UPS to the wall receptacle.
2. Push on the Main Switch till the Green LED (
the Main Switch, then the UPS self-test is being performed. The UPS is in
normal status, and the Green LED (
3. Connect your computer equipment with sockets of the UPS and pull off
the input power cable of the UPS from the wall receptacle to check if the
Line (
alarm buzzer is beeping.
4. Try the field working condition by running some application programs on
your computer and repeating step.
5. Check if the UPS is initiated properly to support continuous operation. Re-
connect the input power cable to the wall receptacle; the UPS will return
to normal status in a few seconds.
IMPORTANT NOTICE: Plug the UPS into the wall outlet to charge the UPS for
over 10 hours before using the UPS.
) LED is flashing every 2 seconds. Meanwhile, please check if
) is ON.
) is extinguished, release
1.7 Front Panel Explanations
On the front panel You can found 1 LED for an easy diagnostic.
A03-PE702 Pag. 18
Page 24
OnePower UPS 700VA/300W(EN)
LED/Button Information
Main Switch ()
LED Line ()
To Control on/off the UPS when Utility is normal. Push
the "Main Switch" for 3 seconds, then release it when
the LED is extinguished
To enable “DC-Start” Function when Utility fails. (To
enable DC Start properly, you are recommended to
connect <80% output load with the UPS only). P.S.
Make sure the computer connected to the UPS is
switched on before enable the "DC-Start" function. You
are not recommended to add some other computer or
peripherals after DC-Start function is activated.
Green LED remains standstill when Utility is normal.
Green LED flashes every 2 seconds and simultaneously
buzzer alarms (beep once every 2 seconds)
continuously when Utility failure.
Green LED flashes once every 0.5 second and
simultaneously buzzer alarms (beep once every 0.5
second) continuously when utility failure and battery is
Low.
Green OFF: to avoid UPS from over-discharge, the UPS
shuts itself down when the battery voltage is too low.
A03-PE702 Pag. 19
Page 25
OnePower UPS 700VA/300W(EN)
1.8 Rear Panel Explanations
Number Explanations
1
2
3
AC Inlet
Backup Outlets: 3pcs IEC320
AC Fuse Holder. (W/fuse) (4A/250Vac).
Sticker with details on the product.
1.9 Replacing the Battery
The Following Precautions Should be Observed When Working on Batteries:
• Remove watches, rings, or other metal objects.
• Use tools with insulated handles.
• Wear rubber gloves and boots.
• Do not lay tools or metal parts on top of batteries.
• Disconnect charging source prior to connecting or disconnecting battery
terminals.
Before beginning the replacing of the battery You have to switch-off all the device
and detach AC cable from the wall receptacle.
A03-PE702 Pag. 20
Page 26
OnePower UPS 700VA/300W(EN)
1. Use a cross-type screwdriver to remove the two screws and slide down the
panel.
2. Gently Pull the battery out of the UPS.
3. Loosen the black wire from the negative (-) terminal and red wire from the
positive (+) terminal.
4. Connect the battery leads to the new battery (small sparks at the battery
connectors are normal during connection).
5. Slide the battery into the UPS.
6. Close the front panel and fasten two screws.
7. Dispose of the old battery properly at an appropriate recycling facility.
NOTE: Once the battery is disconnected, the loads are not protected from power
outages.
A03-PE702 Pag. 21
Page 27
OnePower UPS 700VA/300W(EN)
APPENDIX A: TROUBLE SHOOTING
If the UPS is not functioning properly, you can refer first to this chapter for simple
troubleshooting before contacting your reseller. This could save you time and
effort but if the problem persist, then consult your service provider.
A.1.1 UPS
The LED and the acoustic signals are a profit tool to individualize immediately
possible problems
Situation
Mains normal but
Line () LED is
not on.
Green LED ()
keeps flashing
and alarm buzzer
beeps once every
0.5 second).
UPS turns off
shortly when
Utility Failure.
1. Is the power switch on?
2. Check the Fuse?
3. Is the power cord loose?
1. Battery voltage is too low. 1. Recharge the UPS for 24
1.Check loading status if it is
in overload.
2.Check the battery is
defective or not.
Check Items Solution
1. Press Main Switch on.
2. Change fuse with same
rating.
3. Re-connect the power cord
properly.
hours.
1. Remove some uncritical
load.
2. Change Battery.
UPS is unable to
turn ON/OFF.
No LEDs display
on the front panel
UPS does not
provide expected
backup time.
UPS switch on
then connect
1. Check to see if the Main
Switch On/Off is pushed
longer than 3 seconds or not.
1. The UPS’s battery is weak
due to recent outage.
2. The UPS’s battery is near
the end of its service life.
1. Is the Utility Normal? 1. If Utility is normal, connect
1. Please try again.
1. Contact Atlantis Land.
1. Charge the battery.
2. If the battery is near the end
of its service life, you have
to replace the battery.
Utility first then restart UPS.
A03-PE702 Pag. 22
Page 28
OnePower UPS 700VA/300W(EN)
Utility, but UPS is
unable to work
under Utility
mode.
A.1.2 Battery and Fuse
Situation Solution
Backup time
Wich type of
battery does
UPS use?
How often do I
have to
change
battery?
Where can I
find batteries?
How can I
check the
Fuse?
The battery backup time (sometime called battery reserve
time or battery autonomy) is the length of time the battery will
supply power to the load during a power failure. You can
check on the Appendix Backup Time.
12VDC- 7A/h.
Atlantis recommends to replace the batteries once a year.
1. please contact Your reseller.
2. please contact directly Atlantis Land.
Check the fuse to be sure it is not blown or damaged. Also,
make sure the fuse makes good contact and is not loose in
the fuse holder. Ensure that you are using the correct size
fuse. If you replace the fuse and the UPS again blows the
fuse, please contact Atlantis Land.
Fuse
specification.
[4A, 250Vac] You can found on the rear panel (AC Fuse
holder) a fuse.
A03-PE702 Pag. 23
Page 29
OnePower UPS 700VA/300W(EN)
APPENDIX B: Support
If you have any problems with the UPS, please consult this manual. If you
continue to have problems you should contact the dealer where you bought this
device. If you have any other questions you can contact the Atlantis Land
company directly at the following address:
Atlantis Land SpA
Viale De Gasperi, 122
20017 Mazzo di Rho(MI)
Tel: +39. 02.93906085, +39. 02.93907634(help desk)
Fax: +39. 02.93906161
Copyright. 2002 est la propriété de cette société. Tout droits réservés. Sont
interdites, la reproduction, la transmission, la transcription, la mémorisation dans
un système de sauvegarde où la traduction dans une autre langue ou en langage
informatique quels qu’ils soient, de la présente publication, sous quelque forme
que ce soit ou quelque en soit le moyen, électronique, mécanique, magnétique,
optique, chimique, manuel ou de tout autre genre, sans avoir obtenu
préalablement l’autorisation de notre entreprise.
Non-responsabilité
La présente entreprise n’admet pas de requêtes ni de garantie, explicites ou
implicites, au sujet du contenu et de manière spécifique exclue la possibilité de
garantie, communicabilité ou adaptabilité pour des finalités particulières. Le
logiciel décrit dans le présent manuel est vendu ou concédé en licence “tel quel”.
Si les programmes devaient présenter des problèmes après l’achat, l’acquéreur
(et non pas la présente entreprise, son distributeur ou concessionnaire) est tenu
de prendre en charge tous les coûts de manutention ainsi que les coûts dus à des
dommages accidentels ou des conséquences dérivants d’un défaut du logiciel. La
présente entreprise se réserve en outre le droit de revoir le contenu de cette
publication et d’y apporter des modifications de temps en temps, sans obligation
d’informer les utilisateurs de ces changements. Nous avons fait tout notre
possible afin d’éviter la présence d’erreurs dans le texte, les images, les tableaux
présents dans ce manuel et dans le Cd-Rom. Cependant, nous ne pouvons pas
garantir l’absence totale d’erreurs et/ou d’omissions, nous vous remercions donc
de nous les signaler et vous prions de nous en excuser. Enfin, nous ne pouvons
être tenus pour responsables dans quelque perte que ce soit, dommage ou
incompréhension à la suite directe ou indirecte de l’utilisation de notre manuel, le
logiciel Cd-Rom et/ou disque dur. Toutes les marques ou noms de produits
mentionnés dans le présent manuel sont des marques commerciales et/ou
brevetées par leurs propriétaires respectifs.
Marquage CE
Cet appareil, qui appartient à la Classe B peut causer des interférences radio,
dans ce cas nous vous invitons à prendre les contre-mesures appropriées.
FCC
Cet appareil est conforme à la quinzième partie des Règles de la FCC (Class B).
Son fonctionnement est soumis à deux conditions :
• Il ne doit pas provoquer d’interférences.
• Il ne doit pas subir d’interférences, et notamment pas d’interférences
susceptibles d’entraîner un fonctionnement anormal.
Ces limites sont étudiées de manière à assurer une protection correcte contre les
interférences en zone résidentielle. Cet équipement produit, utilise et peut
A03-PE702 Pag. 25
Page 31
OnePower UPS 700VA/300W(FR)
émettre de l’énergie en fréquences radio. S’il n’est pas installé et utilisé
conformément aux instructions, il peut provoquer des perturbations des
communications radio. L’absence de perturbations ne peut cependant pas être
garantie pour une configuration donnée. Si l’appareil perturbe la réception de la
radio ou de la télévision (ce qui peut être déterminé en l’éteignant puis en le
remettant sous tension), l’utilisateur peut prendre les mesures suivantes pour
corriger ces interférences :
• Réorienter ou déplacer l’antenne réceptrice.
• Augmenter la distance entre le récepteur et l’équipement.
• Brancher l’équipement dans une prise située sur un circuit différent de celui
auquel le récepteur est connecté.
• Demander conseil au revendeur ou à un technicien radio-télévision
expérimenté.
ATTENTION
Ce manuel contient des informations importantes à propos de la sécurité. Suivez
attentivement les instructions pendant l’installation. Lisez les instructions avant de
déballer, installer et mettre en fonction cet appareil.
Pour prévenir les risques de feu ou de choc électrique, installez dans une pièce
dont la température et l’humidité sont contrôlées.
Risque de choc électrique: N'enlevez pas le capot. Ne toucher pas le produit
lorsqu’il est sous tension. Ne soumettez l'entretien qu’à du personnel qualifié. Les
parties actives à l'intérieur de cet UPS peuvent être à de fortes tensions même
lorsque l’alimentation secteur est déconnectée. Le Circuit de la Batterie n'est pas
isolé de l’entrée secteur, une tension dangereuse peut être présente entre les
bornes de la batterie et la terre. Testez avant de toucher.
Attention : Pour garantir l’intégrité et le fonctionnement correct du produit, ne
jamais brancher sur la sortie de l’ UPS des photocopieuses, imprimantes laser,
outils électriques ou une quelconque charge inductive. L'UPS n’est conçu que
pour fonctionner avec un ordinateur.
Attention: Dans l’ UPS est installé une batterie d’accumulateurs qui est une
source d’énergie (à l’intérieur de l’UPS il y a des tensions dangereuses qui sont
présentes même éteint).
Attention: N’ouvrez jamais l’UPS pour le réparer, en agissant de cette façon
vous risquez une décharge électrique et vous n’aurez plus droit à la garantie.
L’UPS peut être réparé uniquement par du personnel qualifié.
Attention: La principale précaution à observer est d’éteindre l’UPS s’il n’est pas
alimenté par le secteur, pour éviter le déchargement total des batteries (situations
de black-out prolongées).
La garantie de la batterie est d’un (1) an à partir de la date d’achat.
En cas de remplacement de la batterie, il faut suivre ces précautions:
• ne porter ni montre, ni bague ou n’importe quel objet métallique;
A03-PE702 Pag. 26
Page 32
OnePower UPS 700VA/300W(FR)
• tenir les outils avec du matériel isolant;
• porter gants en gomme et bottes;
• ne pas toucher la batterie avec un objet en métal;
A la sortie de l’UPS il peut y avoir une tension de 220V même lorsqu’il n’est pas
connecté au réseau électrique. Ne jamais ouvrir le couvercle.
Ne jamais introduire de liquide à l’intérieur de la machine.
A03-PE702 Pag. 27
Page 33
OnePower UPS 700VA/300W(FR)
1.1 Introduction
Ce manuel contient d’importantes informations de sécurité. Suivez attentivement
les instructions pendant l’installation. Nous vous prions de lire attentivement ce
manuel avant l’installation et la mise en service de votre onduleur Atlantis Land,
en vous rappelant que la garantie n’est plus valable si toutes les normes et les
prescriptions indiquées dans ce manuel ne sont pas respectées.
1.2 Vérification
Vérifiez l’UPS dès sa livraison. Prévenez le transporteur ou le vendeur en cas de
dommages. L’emballage est recyclable.
1.3 Dans la boîte
Une fois ouverte, vous devriez trouver les éléments suivants:
OnePower UPS 700VA/300W
2 Câbles IEC
Fusible de rechange (4A/250Vac)
Manuel
Coupon de Garantie
Si vous constatez qu’un de ces composants manque, merci de vous adressez à
votre revendeur.
A03-PE702 Pag. 28
Page 34
OnePower UPS 700VA/300W(FR)
1.4 Mise en place
Pour prévenir les risques de feu ou de choc électrique, installez dans une pièce
dont la température et l’humidité sont contrôlées.
• Cet UPS ne doit être utilisé qu’à l’intérieur.
• Ne pas l’installer à un endroit directement exposé au soleil, la garantie
serait annulée en cas de surchauffe de la batterie.
•Afin d’éliminer les surchauffes, n’obstruez aucune ouie de ventilation, ne
posez aucun objet sur l’UPS et laissez une quinzaine de cms de distance
avec le mur.
A03-PE702 Pag. 29
Page 35
OnePower UPS 700VA/300W(FR)
1.5 Reliez les charges
Connectez en premier l’UPS au secteur, puis branchez les appareils à l’UPS.
Pour utiliser l’UPS comme interrupteur “On/Off”, veillez à mettre sur “On” tous les
appareils.
Attention : Pour garantir l’intégrité et le fonctionnement correct, ne jamais
brancher à la sortie de l’UPS des photocopieuses, imprimantes laser, outils
électriques ou une quelconque charge inductive. L'UPS n’est conçu que pour
fonctionner avec un ordinateur.
A03-PE702 Pag. 30
Page 36
OnePower UPS 700VA/300W(FR)
1.6 Opérations de Test
1. Connectez l’UPS au secteur.
2. Appuyez sur le bouton (pour 3/4 secondes) M/A jusqu'à que la LED est
éteinte. A ce stade l’UPS est bien initialisé (verifier que la LED Ligne
) est allumée).
(
3. Connectez votre équipement informatique et débranchez l’UPS du
secteur afin de contrôler que la LED Ligne (
secondes et que l’alarme émet un signal sonore.
4. Vérifiez le bon fonctionnement en utilisant normalement votre ordinateur.
5. Vérifiez que votre UPS est bien initialisé pour supporter un
fonctionnement continu.
NOTE IMPORTANTE: Avant tout usage, il faut charger l’UPS pendant au moins
10 heures.
) clignote toutes les 2
1.7 Facade
Sur la facade du produit, 1 Led indique l'état de fonctionnement.
LED/Bouton Signification
Bouton M/A ()
Fonction Marche/arrêt lorsque l’UPS est en mode
normal. Appuyez sur le bouton (pour 3/4 secondes) M/A
jusqu'à que la LED est éteinte. A ce stade l’UPS est
bien initialisé (verifier que la LED Ligne () est
allumée).
Pour démarrer le mode Secours (DC-Start). (Attention, il
est recommandé de ne pas dépassé une charge
d’environ 80%)
P.S. Il faut s’assurer que le Pc est en fonction avant de
A03-PE702 Pag. 31
Page 37
OnePower UPS 700VA/300W(FR)
mettre le mode secours (DC-Start), de plus une fois le
mode Secours activé, il ne faut pas brancher de
nouveau périphérique.
LED Ligne ()
1.8 Face arrière
Eclairage continu en fonctionnement.
Clignote avec alarme sonore toutes les 2 secondes en
mode secours (batterie).
Clignote avec alarme sonore 2 fois par secondes
lorsque la batterie est presque déchargée.
La LED est éteinte pour prévenir la complète décharge
de la batterie.
En cas de remplacement de la batterie, il faut suivre ces précautions:
• ne porter ni montre, ni bague ou n’importe quel objet métallique;
A03-PE702 Pag. 32
Page 38
OnePower UPS 700VA/300W(FR)
• tenir les outils avec du matériel isolant;
• porter gants en gomme et bottes;
• ne pas toucher la batterie avec un objet en métal;
•A la sortie de l’UPS il peut y avoir une tension de 220V même lorsqu’il n’est pas
connecté au réseau électrique.
1. Debranchez tous les cables reliés à l’UPS. Avec un tournevis cruciforme
retirez les 2 vis sous la facade.
2. Tirez doucement la batterie vers l’extérieur.
3. Déconnectez le câble noir (-) puis le câble rouge (+) des bornes.
4. Connectez les cables à la nouvelle batterie (de petites étincelles
peuvent se produire aux bornes de la batterie).
5. Glissez la batterie dans l’UPS
6. Repositionnez les panneaux puis les vis.
7. Jetez la vieille batterie dans un endroit approprié (pollution).
ATTENTION: Une fois la batterie déconnectée, la charge n’est plus protégée en
cas de coupure de l’alimentation électrique.
A03-PE702 Pag. 33
Page 39
OnePower UPS 700VA/300W(FR)
APPENDICE A: Problèmes
Lorsque l’onduleur ne fonctionne pas correctement, avant de vous adressez au
service après vente, consultez ce chapitre.
A.1.1 Problèmes
Les LEDs et les signaux sonores sont des indicateurs utiles pour déterminer
d’éventuels problèmes, en observant l'état et/ou en écoutant les beep il est
possible de déterminer rapidement un éventuel mauvais fonctionnement.
Situation Verification Solution
Secteur normal
mais la Ligne LED
() est éteinte.
La LED ()
clignote 2 fois par
seconde mais il
n’y a pas de sortie
220V.
Lorsqu’il n’y a
plus de Secteur
l’UPS s’éteint.
L’UPS ne passe
pas de Marche à
1. Bouton M/A sur Marche?
2. Controlez le fusible!
3. Câble secteur déconnecté?
1. Batterie déchargée1. Rechargez l’UPS pendant
1. Trop de charge!
2. Verifiez la batterie.
1. Vérifiez que l’appui sur la
touche M/A est bien
1. Pressez le bouton M/A.
2. Changez le fusible par un
modèle identique.
3. Reconnectez le câble.
24 heures.
1. Retirez des charges peu
importantes.
2. Chargez la batterie.
2. Recommencez.
Arrêt.
Aucune LED
allumée en face
avant.
L’UPS n’assure
plus un temps de
sauvegarde
normal.
Le secteur 220V
1.La batterie vient d’être
2. La batterie est en fin de vie.
1. Le secteur est il réellement 2. Débranchez l’UPS du
supérieur à 3 secondes.
déchargée.
A03-PE702 Pag. 34
1. Consultez la Hot-Line
1.Chargez la batterie.
2. Remplacez la batterie.
Page 40
OnePower UPS 700VA/300W(FR)
présent, l’UPS est
en fonction, mais
il ne fonctionne
pas (led Ligne
n’est pas fixe).
disponible? secteur, rebranchez le puis
A.1.2 Batterie et Fusible
Question Solution
Durée du
secours
(backup time)
Durée pendant laquelle l'UPS peut maintenir le bon
focntionnement de la charge avant le déchargement complet
de la batterie. Cette durée dépend évidemment du type de
charge. Voir la section à la fin du manuel pour de plus amples
détails.
faites le démarrer.
Type de batterie
utilisée dans
l'UPS
Durée de vie de
la batterie
Où trouver la
batterie?
Comment
vérifier le
fusible?
Qu’elles sont
les
caractéristiques
du Fusible?
12VDC- 7A/h.
Dépendante de l’utilisation, une bonne règle consiste à tester
périodiquement l'état de détérioration de la batterie.
Il est recommandé de la remplacer une fois par an.
1. n'importe quel magasin spécialisé.
2. vous pouvez aussi contacter votre distributeur.
Enlever le fusible et contrôler visuellement le filament intérieur
(mieux encore, utiliser un contrôleur de continuité). Si le fusible
est défectueux le remplacer.
4A, 250Vac.
A03-PE702 Pag. 35
Page 41
OnePower UPS 700VA/300W(FR)
APPENDICE B: Assistance
Pour tous problèmes ou renseignements vous pouvez contacter la « help desk »
téléphonique gratuite d’Atlantis Land qui vous fournira assistance du:
lundi au jeudi de 9.00 à 13.00 et 14.00 à 18.00 et le vendredi de 9.00 à 13.00.
Vous pouvez aussi nous contacter par email : tech-fr@atlantis-land.com
Atlantis Land France
57, Rue d’Amsterdam
75008 Paris
Email: tech-fr@atlantis-land.com
Site Web: http://www.atlantis-land.fr
Important :
Pensez à consulter notre site Web, pour prendre connaissance d’éventuelles
mises à jour.