Atec XDS User Manual

Argantix XDS Series
5–15 kW
Overview
Compact Modular DC Power 5, 10 and 15 KW versions in 3U, 19” rack.
Wide Range of Applications Telecommunications, automotive, industrial and commercial applications.
Fast Transient Response Capable of driving demanding loads.
Parallel / Current Share Capability Paralleled chassis can deliver up to 75 KW.
Standard RS232C Interface and Optional GPIB. Instrument drivers and software support for easy system integration.
Compact Power
The XDS Series packs up to 15 KW of DC power into a 5.25” rack mount chassis. Despite the high power density of this design, the XDS Series provides a low noise, stable output.
A full set of measurements is built-in to provide instant feedback on EUT load characteristics.
The XDS Series offers all the basic DC power supply capabilities needed for a wide range of applications and provides cost effective alternative to larger and more expensive products typically used for these applications.
Easy To Use Controls
Simple menu driven operation and familiar rotary controls for setting voltage and current ensures that the XDS Series Power Supplies are easy to operate. All front panel controls including the rotary knobs are digitally encoded for long lasting, trouble free operation. The voltage and current control knobs can be used to quickly slew output parameters.
The intuitive front panel controls allow for easy operation of the supply by both novice and experienced users alike.
Applications
With excellent output regulation and accuracy, the XDS Series DC Power Supplies support a wide variety of DC power applications. Examples include communications, semiconductors, automotive, information technology and industrial. The standard RS232C serial interface supports remote control of all power supply
functions and measurements and allows for easy integration into ATE systems. Use of standard SCPI command language syntax and instrument drivers for popular programming environments further ease system integration. An optional GPIB interface is available as well.
XDS Series - GUI Software
All XDS Series Power Supplies come with Windows GUI software. This GUI program offers additional functionality. This includes the following capabilities:
Output Sequencing: Time driven output changes can be programmed, stored and executed under program control. Events include steps, sweeps, drops and surges of voltage and/or current. This allows a variety of power conditions and DC tests to be set up without having to develop application specic code. Multiple setups can be stored on disk.
Data Logging: All measurements taken from the DC supply can be recorded to disk in a format that is easily exported to other programs such as MS Excel for analysis and display.
Pass/Fail Testing: Automatic output sequencing and data read back with user dened pass/fail criteria. This mode may be used for burn-in or product evaluation applications. A simple to use spreadsheet-like user interface allows entry of time delays, settings, readings and pass/fail limits. Any number of setups can be saved to disk for future use.
The GUI program operates over the standard RS232C interface or the optional IEEE-488/GPIB interface and provides comprehensive on-line help.
30–600 V
8–500 A
208 400 480
Calle del Ebano #16625 Jardines de Chapultepec Tijuana B.C. Mexico Tel. (664) 681 1130 Fax. (664) 681 1150 Tel. 01800 027-4848 www.finaltest.com.mx
858.458.0223
sales@ProgrammablePower.com 67
XDS Series
XDS Series - Models¹ : Output
Model Voltage Current RMS Noise Model Vpltage Current RMS Noise
XDS 30-167 0-30 0-167 15mv XDS 150-33 0-150 0-33 25mv
XDS 30-333 0-30 0-333 15mv XDS 150-66 0-150 0-66 25mv
XDS 30-500 0-30 0-500 15mv XDS 150-100 0-150 0-100 25mv
XDS 40-125 0-40 0-125 15mv XDS 300-17 0-300 0-17 100mv
XDS 40-250 0-40 0-250 15mv XDS 300-33 0-300 0-33 100mv
XDS 40-375 0-40 0-375 15mv XDS 300-50 0-300 0-50 100mv
XDS 50-100 0-50 0-100 15mv XDS 400-12 0-400 0-12.5 100mv
XDS 50-200 0-50 0-200 15mv XDS 400-25 0-400 0-25 100mv
XDS 50-300 0-50 0-300 15mv XDS 400-37 0-400 0-37 100mv
XDS 80-62 0-80 0-62 25mv XDS 600-8 0-600 0-8 250mv
XDS 80-125 0-80 0-125 25mv XDS 600-17 0-600 0-17 250mv
XDS 80-187 0-80 0-187 25mv XDS 600-25 0-600 0-25 250mv
XDS 100-50 0-100 0-50 25mv
XDS 100-100 0-100 0-100 25mv
DS 100-150 0-100 0-150 25mv
Electrical
Output Power Maximum 5, 10 or 15 KW Voltage Accuracy: 0.3 % FS
Resolution: 0.033 % FS Line Regulation: < 0.1% of V range Load Regulation: < 0.1% of V range Transient Response: Voltage will recover to within 2% of V range within 2 msec for 30 % load step. Stability: ± 0.05% of max. rating per 8 hours after 30 mins. warmup period.
Current Accuracy: 0.5% FS at 0-100% of range Resolution: 0.1%-0.033 % (model specic) Line Regulation: < 0.1% of I range Load Regulation: < 0.1% of I range Stability: ± 0.05% of max. rating per 8 hours after 30 mins. warmup period
Input Voltage: 208 - 10 % to 230 + 10% VAC 400 ± 10 % VAC (option -400) 480 ± 10 % VAC (option -480) All inputs are L-L, 3 phase, 3­ wire plus safety ground. Current RMS: Typical RMS current per phase at low line input voltage. Power Factor: > 0.65 Efciency: > 85 % at full load.
Power Level
Vlow 5 kW 10 kW 15 kW
187 V 27 A 54 A 81 A
360 V 15 A 30 A 45 A
432 V 12A 24 A 36 A
Measurements
Voltage Model Resolution Accuracy
XDS 30-XXX 0.01 V 0.05 V XDS 40-XXX 0.01 V 0.05 V XDS 50-XXX 0.02 V 0.1 V XDS 80-XXX 0.02 V 0.1 V XDS 100-XXX 0.1 V 0.2 V XDS 150-XXX 0.1 V 0.3 V XDS 300-XXX 0.1 V 0.5 V XDS 400-XXX 0.1 V 0.5 V XDS 600-XXX 0.2 V 1.0 V
Current Current Range Resolution Accuracy
0 - 8.3 A 0.003 A 0.013 A 0 - 16 A 0.005 A 0.025 A 0 - 33 A 0.01 A 0.05 A 0 - 66 A 0.02 A 0.1 A 0 - 187 A 0.1 A 0.3 A 0 - 400 A 0.1 A 0.5 A 0 - 500 A 0.2 A 1 A
Power Range Resolution Accuracy
0 - 5 KW 1 W 0.3 % FS 0 - 10 KW 2 W 0.3 % FS 0 - 15 KW 5 W 0.3 % FS
Peak Current Resolution: See current table Accuracy: Same as current + 3 x resolution.
Protection Over temperature, short circuit, over current protection