Argantix XDS Series
5–15 kW
Overview
• Compact Modular DC Power
5, 10 and 15 KW versions in 3U, 19” rack.
• Wide Range of Applications
Telecommunications, automotive, industrial and
commercial applications.
• Built-in Measurements
Voltage, current and power readback
capability standard.
• Fast Transient Response
Capable of driving demanding loads.
• Parallel / Current Share Capability
Paralleled chassis can deliver up to 75 KW.
• Standard RS232C Interface and Optional GPIB.
Instrument drivers and software support for easy
system integration.
Compact Power
The XDS Series packs up to 15 KW of DC power
into a 5.25” rack mount chassis. Despite the
high power density of this design, the XDS Series
provides a low noise, stable output.
A full set of measurements is built-in to provide
instant feedback on EUT load characteristics.
The XDS Series offers all the basic DC power
supply capabilities needed for a wide range of
applications and provides cost effective alternative
to larger and more expensive products typically
used for these applications.
Easy To Use Controls
Simple menu driven operation and familiar rotary
controls for setting voltage and current ensures
that the XDS Series Power Supplies are easy
to operate. All front panel controls including
the rotary knobs are digitally encoded for long
lasting, trouble free operation. The voltage and
current control knobs can be used to quickly slew
output parameters.
The intuitive front panel controls allow for easy
operation of the supply by both novice and
experienced users alike.
Applications
With excellent output regulation and accuracy,
the XDS Series DC Power Supplies support a
wide variety of DC power applications. Examples
include communications, semiconductors,
automotive, information technology and
industrial. The standard RS232C serial interface
supports remote control of all power supply
functions and measurements and allows for easy
integration into ATE systems. Use of standard
SCPI command language syntax and instrument
drivers for popular programming environments
further ease system integration. An optional GPIB
interface is available as well.
XDS Series - GUI Software
All XDS Series Power Supplies come with
Windows GUI software. This GUI program
offers additional functionality. This includes the
following capabilities:
Output Sequencing: Time driven output
changes can be programmed, stored and
executed under program control. Events include
steps, sweeps, drops and surges of voltage and/or
current. This allows a variety of power conditions
and DC tests to be set up without having to
develop application specic code. Multiple setups
can be stored on disk.
Data Logging: All measurements taken from the
DC supply can be recorded to disk in a format
that is easily exported to other programs such as
MS Excel for analysis and display.
Pass/Fail Testing: Automatic output sequencing
and data read back with user dened pass/fail
criteria. This mode may be used for burn-in or
product evaluation applications. A simple to use
spreadsheet-like user interface allows entry of
time delays, settings, readings and pass/fail limits.
Any number of setups can be saved to disk for
future use.
The GUI program operates over the standard
RS232C interface or the optional IEEE-488/GPIB
interface and provides comprehensive on-line
help.
30–600 V
8–500 A
208 400 480
Calle del Ebano #16625
Jardines de Chapultepec
Tijuana B.C. Mexico
Tel. (664) 681 1130
Fax. (664) 681 1150
Tel. 01800 027-4848
www.finaltest.com.mx
858.458.0223
sales@ProgrammablePower.com 67
XDS Series
XDS Series - Models¹ : Output
Model Voltage Current RMS Noise Model Vpltage Current RMS Noise
XDS 30-167 0-30 0-167 15mv XDS 150-33 0-150 0-33 25mv
XDS 30-333 0-30 0-333 15mv XDS 150-66 0-150 0-66 25mv
XDS 30-500 0-30 0-500 15mv XDS 150-100 0-150 0-100 25mv
XDS 40-125 0-40 0-125 15mv XDS 300-17 0-300 0-17 100mv
XDS 40-250 0-40 0-250 15mv XDS 300-33 0-300 0-33 100mv
XDS 40-375 0-40 0-375 15mv XDS 300-50 0-300 0-50 100mv
XDS 50-100 0-50 0-100 15mv XDS 400-12 0-400 0-12.5 100mv
XDS 50-200 0-50 0-200 15mv XDS 400-25 0-400 0-25 100mv
XDS 50-300 0-50 0-300 15mv XDS 400-37 0-400 0-37 100mv
XDS 80-62 0-80 0-62 25mv XDS 600-8 0-600 0-8 250mv
XDS 80-125 0-80 0-125 25mv XDS 600-17 0-600 0-17 250mv
XDS 80-187 0-80 0-187 25mv XDS 600-25 0-600 0-25 250mv
XDS 100-50 0-100 0-50 25mv
XDS 100-100 0-100 0-100 25mv
DS 100-150 0-100 0-150 25mv
Electrical
Output
Power Maximum 5, 10 or 15 KW
Voltage Accuracy: 0.3 % FS
Resolution: 0.033 % FS
Line Regulation: < 0.1% of V range
Load Regulation: < 0.1% of V range
Transient Response: Voltage will recover
to within 2% of V range within 2 msec
for 30 % load step.
Stability: ± 0.05% of max. rating per 8
hours after 30 mins. warmup period.
Current Accuracy: 0.5% FS at 0-100% of range
Resolution: 0.1%-0.033 %
(model specic)
Line Regulation: < 0.1% of I range
Load Regulation: < 0.1% of I range
Stability: ± 0.05% of max. rating per 8
hours after 30 mins. warmup period
Input Voltage: 208 - 10 % to 230 +
10% VAC
400 ± 10 % VAC (option -400)
480 ± 10 % VAC (option -480)
All inputs are L-L, 3 phase, 3 wire plus safety ground.
Current RMS: Typical RMS current per
phase at low line input voltage.
Power Factor: > 0.65
Efciency: > 85 % at full load.
Power Level
Vlow 5 kW 10 kW 15 kW
187 V 27 A 54 A 81 A
360 V 15 A 30 A 45 A
432 V 12A 24 A 36 A
Measurements
Voltage
Model Resolution Accuracy
XDS 30-XXX 0.01 V 0.05 V
XDS 40-XXX 0.01 V 0.05 V
XDS 50-XXX 0.02 V 0.1 V
XDS 80-XXX 0.02 V 0.1 V
XDS 100-XXX 0.1 V 0.2 V
XDS 150-XXX 0.1 V 0.3 V
XDS 300-XXX 0.1 V 0.5 V
XDS 400-XXX 0.1 V 0.5 V
XDS 600-XXX 0.2 V 1.0 V
Current
Current Range Resolution Accuracy
0 - 8.3 A 0.003 A 0.013 A
0 - 16 A 0.005 A 0.025 A
0 - 33 A 0.01 A 0.05 A
0 - 66 A 0.02 A 0.1 A
0 - 187 A 0.1 A 0.3 A
0 - 400 A 0.1 A 0.5 A
0 - 500 A 0.2 A 1 A
Power
Range Resolution Accuracy
0 - 5 KW 1 W 0.3 % FS
0 - 10 KW 2 W 0.3 % FS
0 - 15 KW 5 W 0.3 % FS
Peak Current
Resolution: See current table Accuracy: Same as
current + 3 x resolution.
Protection
Over temperature, short circuit, over
current protection
www.ProgrammablePower.com68