Atec VSS500N10-3 User Manual

DATA SHEET > VSS 500N10.3 > 20130628
VSS 500N10.3
1.2/50US SURGE GENERATOR FOR SOLAR PANEL TESTING
FOR TESTS ACCORDING TO ...
> EN 61730-1 > EN 61730-2 > IEC 60060 > IEC 61730-1 > IEC 61730-2 > UL 1703
The surge generator type VSS 500N10.3 is specifically designed to generate high voltage transients as required by IEC/EN 61730-2 for safety testing of photo voltaic panels. The specified waveshape of 1.2/50us must be generated and maintained as specified across a broad range of capacitance the PV's do represent and as such the generator needs to be based on different pulse shaping networks to cope with the variable capacitive load of the panels depending on their size and design.
HIGHLIGHTS
> Surge voltage up to 10kV > 7 different capacitance ranges selectable from
30nF to 180nF > Generator compliant to IEC/EN 61730-1/2 > Peak voltage measurement > Interlock > Warning lamp control > Manual operation
APPLICATION AREAS
INDUSTRY
COMPONENTS
RESIDENTIAL
RENEWABLE ENERGY
www.emtest.com © EM TEST > PAGE 1/3
DATA SHEET > VSS 500N10.3 > 20130628
TECHNICAL DETAILS
VSS 500N10.3 - 1.2/50US SURGE GENERATOR
VOLTAGE PULSE
Voltage (open circuit)
Front time 1.2us +/-30% Time to half value 50us +/-20% Pulse shaping
networks Capacitance
ranges
Wave Shape As per IEC 60060-1 Polarity Positive/negative/alternating Event counter 1 to 30,000 or endless, selectable
500V to 10,000V +/-10%
Depending on load capacitance
30nF to 180nF in 7 ranges Range 35nF; 30nF to 40nF Range 45nF; 40nF to 50nF Range 55nF; 50nF to 65nF Range 72nF; 65nF to 85nF Range 100nF; 85nF to 110nF Range 130nF; 110nF to 140nF Range 160nF; 140nF to 180nF
TEST ROUTINES
Quick Start Immediate start; easy to use and fast User Test
Routines Standard Test
Routines
Service Service, set-up, self test
INTERFACE
Optical interface Opto link, 3 m cable
Parallel interface IEEE 488, addresses 1 to 30
SAFETY
Safety circuit Control input (24Vdc) Warning lamp Floating output contact
Change polarity Change voltage
IEC 61730-2 range 35nF IEC 61730-2 range 45nF IEC 61730-2 range 55nF IEC 61730-2 range 72nF IEC 61730-2 range 100nF IEC 61730-2 range 130nF IEC 61730-2 range 160nF
USB A connector
TRIGGER
Automatic Automatic pulse release Manual Single pulse release External External pulse release CRO trigger 5V trigger signal for oscilloscope Pulse repetition
rate
OUTPUT
Direct Via HV connector
MEASUREMENTS
Peak voltage 10,000V in the LCD display Peak current In the LCD display
2s to 999s depending on the voltage min. 10s @ 10kV
Direct connection to the DUT or via connection box
GENERAL DATA
Dimensions, weight
Supply voltage 115V/230V +10%/-15% Fuses 2 x T2AT (230V) or 2 x T4AT (115V)
ACCESSORIES
Scope of delivery 2*1m HV leads, one end open,
PV Test Kit Set of test accessories including
OPTIONS
iec.control 1 Remote control and documentation
19"/6HU, approx. 22kg
Mains supply cable (depends on country), Operation manual
- Connection box
- Cables
- Copper tape, self-adhesive
software, including standard test routines and reporting capabilities.
www.emtest.com © EM TEST > PAGE 2/3
Loading...
+ 1 hidden pages