Megger’s new S1-Series of insulation resistance testers consist of a 5 kV model, S1-568 and a 10 kV model, S1-1068. These top end instruments are targeted at power utilities and service companies working in generation, transmission and distribution markets. Class leading charge current, noise rejection and software filters make the S1-Series Megger’s most advanced DC insulation resistance testers to date.
Instrument productivity is a focus of the new S1-Series which offers rapid charge batteries and operation from an AC source when the battery is flat. An intuitive user interface ensures no lost time remembering how to use the tester. Simplicity of operation is achieved with two rotary switches and a large backlight display which enables multiple results to be displayed simultaneously. A graphical quick start guide is provided inside the lid of each model to assist first time users.
Safety of operation is built in, 5 kV and 10 kV models are safety rated to CAT IV 600 V up to 3000 m. Original equipment manufacturers and repairers will welcome the remote control feature allowing them to automate resistance testing on the factory floor, as will technicians in substations wanting to operate from a more convenient, safe distance.
The S1-Series have a dual case design with a tough outer case to protect the tester from knocks and drops and a fire retardant inner case. The case IP rating prevents moisture and dust ingress when storing or carrying the instrument. The lids have clip-on lead pouches ensuring that leads remain with the instrument at all times. Case lids are removable for improved access to the terminals.
Five preset voltage ranges are provided in insulation test mode, plus a user settable lock voltage range. Preconfigured diagnostic tests include Polarisation Index (PI), Dielectric Absorption Ratio (DAR), Dielectric Discharge (DD), Stepped Voltage (SV) and Ramp test.
Advanced memory storage includes time/date stamping of results, logging of data and recall of results to screen. A fully isolated USB interface or on-board Bluetooth® interface is used for safe transfer of data to Megger’s asset management software; PowerDB Pro, Advanced or Lite packages.
Test leads are double insulated with clamps rated at 3 kV t equivalent to 6 kV single insulation for the medium clip leadset and 5 kV t equivalent to 10 kV single insulation for the large clip leadset.
FEATURES
■
Resistance measurement: 15 TΩ - 5 kV, 35 TΩ - 10 kV
High current – 6 mA short circuit current, 2 mA charge
current
High noise immunity – 8 mA of noise rejection
Four software filters: 10s, 30s, 100s, 200s
Li-ion battery – charges in 2 hours and gives up to 6 hours
continuous testing a 100 MΩ load (S1-568), battery meets IEC 62133
CATIV 600 V safety rating up to 3000m
Remote operation via USB cable
Download of memory via isolated USB cable or Bluetooth
Timed IR, DAR, PI, DD, SV and ramp diagnostic tests
Large LCD display with backlight
Dedicated voltmeter function (30 V to 660 V) AC or DC
Advanced memory, on screen recall and real time clock for
date/time stamped results
PowerDB Lite asset management software
Option to record temperature, humidity (measured independently)
S1-568 and S1-1068
5 & 10 kV DC Insulation Resistance Testers
APPLICATION
The Insulation Resistance (IR) test is a quantitative test which indicates the effectiveness of a product’s electrical insulation. Applications include cables, transformers, motors/generators, circuit breakers and bushings. Common insulation tests are the “spot test”, a 1 minute IR test and a 10 minute Polarisation Index (PI) test, where PI is the ratio R
10min/R1min
and temperature
independent.
ELECTRICAL SPECIFICATIONS
AC voltage input range: 90 - 264 V rms, 50/60 Hz, 100 VA Battery: 11.1 V, 5.2 Ah meets IEC 62133:2003 Battery life S1-568: 6 hours (typical) continuous testing at 5 kV with a 100 MΩ load Battery life S1-1068: 4.5 hours (typical) continuous testing at 10 kV with a 100 MΩ load Battery charge time: 2.5 hours from deep discharge, 2 hours normal discharge 30 min. quick charge: 1 hour operation at 5 kV, 100 MΩ Test voltages: 250 V (5 kV only), 500 V, 1000 V, 2500 V, 5000 V, 10000 V, VL Lock test voltage: 40 V to 1 kV in 10 V steps, 1 kV to 5 kV in 25 V steps, 5 kV to 10 kV in 25 V steps Voltage o/p accuracy: +4%, -0%, ±10 V nominal test volt­age at 1GΩ load (0 °C to 30 °C) Resistance range: 10 kΩ to 15 TΩ @ 5 kV, 10 kΩ to 35 TΩ @ 10 kV Accuracy (23 °C):
S1-568 5000 V 2500 V 1000 V 500 V 250 V
±5% to 1 TΩ 500 GΩ 200 GΩ 100 GΩ 50 GΩ
±20% to 10 TΩ 5 TΩ 2 TΩ 1 TΩ 500 GΩ
S1-1068 10 kV 5000 V 2500 V 1000 V 500 V 250 V
±5% to 2 TΩ 1 TΩ 500 GΩ 200 GΩ 100 GΩ 50 GΩ
±20% to 20 TΩ 10 TΩ 5 TΩ 2 TΩ 1 TΩ 500 GΩ Guard performance: 2% error guarding 500 kΩ leakage with 100 MΩ load Display range analogue: 100 kΩ to 10 TΩ Display range digital: 10 kΩ to 35 TΩ Short circuit current: 6 mA nominal
Charge current: 2 mA Insulation alarm: 100 kΩ to 10 GΩ Capacitor charge battery power: <2.5 s/μF to 5 kV, <5 s/μF to 10 kV
Capacitor charge AC power: <1.5 s/μF to 5 kV, <2.7 s/μF to 10 kV Capacitor discharge: 5 kV to 50 V: <120 ms/ μF 10 kV to 50 V: <250 ms/ μF Capacitance range: 10 nF to 50 μF (dependant on (> 500 V) measurement voltage) Capacitance accuracy (23 °C): ±10% ±5 nF Current measurement range: 0.01 nA to 6 mA accuracy (23 °C): ±5% ±0.2 nA at all voltages Interference rejection: 8 mA Software filtering: 4 filter settings: 10s, 30s, 100s, 200s Voltmeter range: 30 V to 660 V ac or dc, 45 Hz - 65 Hz
ELECTRICAL SPECIFICATIONS CONT
Voltmeter accuracy: ±3%, ±3 V Timer range: Up to 99 minutes 59 seconds, 15 second minimum setting Memory capacity: 11 hrs logging @ 5 sec intervals Test regimes: IR, IR(t), DAR, PI, DD, SV, ramp test Interfaces: USB type B (device), Bluetooth® Real time output: reading/s (V, I, R) at a rate of 1 Hz Remote control: Remote control via USB cable only (requires RC indicator to be in position)
ENVIRONMENTAL SPECIFICATIONS
CATIV 600 V safety rating up to 3000 m @ 10 kV with safety plug or guard lead inserted in guard terminal CATIV 600 V safety rating up to 3000 m @ 5 kV S1-1068 Altitude: 3000 m (with all three leads are connected or when safety plug is inserted in the guard terminal) S1-568 Altitude: 3000 m Operating temperature: -20 °C to 50 °C Storage temperature: -25 °C to 65 °C Humidity: 90% RH non-condensing at 40 °C Ingress protection: IP65 (lid closed), IP40 (lid open)
SAFETY SPECIFICATIONS
Safety: Meets the requirements of IEC 61010-1, CATIV 600 V EMC: Meets the requirements of IEC61326-1 Dimensions: L 315 mm x W 285 mm x H 181 mm Weight: 4.5 kg