Unit specifications..........................................................................................................................................................3
TCXO time base ..............................................................................................................................................................3
Reference frequency input.............................................................................................................................................3
Power meter (frequency-selective) and power versus time....................................................................................................................6
Guard time measurement .......................................................................................................................................................................8
AF generator...........................................................................................................................................................................................8
AF analyzer.............................................................................................................................................................................................8
R&S®CBT-B42 digital audio interface............................................................................................................................9
Inputs and outputs (rear panel).....................................................................................................................................9
General data ..................................................................................................................................................................10
Specifications apply under the following conditions: Data without tolerance limits is not binding.
®
In line with the Bluetooth
Mbps is not an SI unit.
The specifications for the R&S
Note:
The Bluetooth
Rohde & Schwarz is under license.
®
word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by
Core Specification, bit rates are specified in Mbps (million bits per second).
®
CBT/R&S®CBT32 refer to a fully equipped unit with all applicable options installed.
2 Rohde & Schwarz R&S
®
CBT/R&S®CBT32 Bluetooth® Tester
Version 06.00, April 2009
Unit specifications
Standards Bluetooth® Core Specification
Version 2.1+EDR: test mode supported
Radio Frequency Test Specification
V1.2/V2.0/V2.0+EDR/V2.1+EDR
Bluetooth
®
Low Energy Specification
TCXO time base
Max. frequency drift in temperature range +5 °C to +45 °C ±1 × 10–6
Max. aging ±1 × 10–6/year
Reference frequency input
Synchronization input BNC connector REF IN
sinewave 10 MHz Frequency
squarewave (TTL level) 10 MHz
Max. frequency variation ±5 × 10–6
Input voltage range 0.5 V to 2 V, rms
Impedance 50 Ω
RF generator
Bluetooth® menu 2402 MHz + k × 1 MHz, k = 0 to 93 RF channel definition
Bluetooth
®
LE menu 2404 + k × 2 MHz, k = 0 to 10
2406 + k × 2 MHz, k = 11 to 36
channel 37 = 2402 MHz
channel 38 = 2426 MHz
channel 39 = 2480 MHz
Frequency range
Frequency resolution channel spacing in line with standard 1 MHz
Frequency offset range ±250 kHz
Frequency offset resolution 1 kHz
Frequency uncertainty
Hopping scheme
Output level range
RF IN/OUT
RF menu 2398 MHz to 2499 MHz
Bluetooth® menu 2402 MHz to 2495 MHz
Bluetooth
RF menu ±5 Hz + drift of time base
Bluetooth
modes in line with Bluetooth
Bluetooth
for basic rate packets and for
Bluetooth
for EDR packets (2-DHx, 3-DHx) –90 dBm to –3 dBm
®
LE menu 2402 MHz to 2480 MHz
®
and Bluetooth® LE menu ±100 Hz + drift of time base
®
standard
®
Low Energy no hopping and no signaling
®
Low Energy packets
Europe (except France), USA
France
RX/TX single frequency
reduced hopping
–90 dBm to +0 dBm
Rohde & Schwarz R&S
®
CBT/R&S®CBT32 Bluetooth® Tester 3
Version 06.00, April 2009
Output level uncertainty in temperature range +20 °C to +35 °C
RF IN/OUT
output level < –10 dBm < 1.0 dB
output level ≥ –10 dBm < 1.5 dB
in temperature range +5 °C to +45 °C
output level < –10 dBm < 1.5 dB
output level ≥ –10 dBm < 2.0 dB
Output level resolution 0.1 dB
Generator RF output level repeatability typical values after 1 h warm-up time at
< 0.03 dB
constant ambient temperature
VSWR
RF IN/OUT < 1.5
Attenuation of harmonics f
= 2398 MHz to 2499 MHz, up to 7 GHz
0
RF IN/OUT > 30 dB
Attenuation of nonharmonics > 50 dB
GFSK modulation
GFSK bit rate DHx packet types 1 Mbps, B × T = 0.5
Modulation index 11110000 pattern
0.32
frequency deviation 160 kHz
Modulation index range frequency deviation 100 kHz to 220 kHz 0.20 to 0.44
Modulation index resolution 0.01
Modulation index uncertainty 11110000 pattern
±1 %
frequency deviation 160 kHz
in temperature range +20 °C to +35 °C
DPSK modulation
π/4DQPSK bit rate 2-DHx packet types 2 Mbps
8DPSK bit rate 3-DHx packet types 3 Mbps
Symbol rate 1 Msps
Modulation uncertainty DEVM ≤ 5 %, rms
®
GFSK modulation Bluetooth
GFSK bit rate RF_PHY_Test_Ref, ADV_IND,
Low Energy
1 Mbps, B × T = 0.5
ADV_NONCONN_IND and DATA packet
types
Modulation index 11110000 pattern
0.50
frequency deviation 250 kHz
Modulation index range frequency deviation 200 kHz to 300 kHz 0.40 to 0.60
Modulation index resolution 0.01
Modulation index uncertainty 11110000 pattern
±1 %
frequency deviation 250 kHz
in temperature range +20 °C to +35 °C
Dirty TX (basic rate)
Frequency offset range ±250 kHz
Frequency offset resolution 1 kHz
Frequency offset uncertainty ±5 Hz + drift of time base
Modulation index range 0.20 to 0.44
Modulation index resolution 0.01
Modulation index uncertainty 11110000 pattern
±1 %
in temperature range +20 °C to +35 °C
Symbol time error range ±20 ppm
Symbol time error resolution 1 ppm
®
4 Rohde & Schwarz R&S
CBT/R&S®CBT32 Bluetooth® Tester
Version 06.00, April 2009
Symbol time error uncertainty same as time base
Drift mode
drift is dependent on packet type:
ON/OFF
DH1: frequency modulation
with ±25 kHz deviation and 1600 Hz
sinewave modulation frequency
DH3: frequency modulation
with ±40 kHz deviation and 500 Hz
sinewave modulation frequency
DH5: frequency modulation
with ±40 kHz deviation and 300 Hz
sinewave modulation frequency
successive packets have alternating start
phases of 0°/180°
Frequency offset range ±250 kHz
Frequency offset resolution 1 kHz
Frequency offset uncertainty ±5 Hz + drift of time base
Symbol time error range ±20 ppm
Symbol time error resolution 1 ppm
Symbol time error uncertainty same as time base
Drift mode frequency modulation with ±10 kHz
ON/OFF
deviation and sinewave modulation period
of 100 µs; successive packets have
alternating start phases of 0°/180°
Frequency offset range ±250 kHz
Frequency offset resolution 1 kHz
Frequency offset uncertainty ±5 Hz + drift of time base
Modulation index range 0.40 to 0.60
Modulation index resolution 0.01
Modulation index uncertainty 11110000 pattern
±1 %
in temperature range +20 °C to +35 °C
Symbol time error range ± 50 ppm
Symbol time error resolution 1 ppm
Symbol time error uncertainty same as time base
Drift mode frequency modulation with ±50 kHz
ON/OFF
deviation and sinewave modulation period
of 1600 µs (625 Hz); successive packets
have alternating start phases of 0°/180°
Note: Both the basic rate and EDR dirty transmitter, with the Specification Table setting, are in line with the Bluetooth
Frequency Test Specification V1.2/V2.0+EDR/V2.1+EDR, supporting both single-slot and multi-slot ACL packets.
®
Radio
Rohde & Schwarz R&S
®
CBT/R&S®CBT32 Bluetooth® Tester 5
Version 06.00, April 2009
RF analyzer
VSWR
RF IN/OUT 2398 MHz to 2499 MHz < 1.5
®
Bluetooth
Bluetooth
menu 2402 MHz + k × 1 MHz, k = 0 to 93 RF channel definition
®
LE menu 2404 + k × 2 MHz, k = 0 to 10
2406 + k × 2 MHz, k = 11 to 36
channel 37 = 2402 MHz
channel 38 = 2426 MHz
channel 39 = 2480 MHz
Frequency range
RF menu 2398 MHz to 2499 MHz
Bluetooth® menu 2402 MHz to 2495 MHz
Bluetooth
®
LE menu 2402 MHz to 2480 MHz
Frequency resolution channel spacing in line with standard 1 MHz
Frequency uncertainty ±5 Hz + drift of time base
Hopping scheme
modes in line with Bluetooth
standard
Europe (except France), USA
France
®
RX/TX single frequency
reduced hopping
Bluetooth
®
Low Energy no hopping and no signaling
Power meter (frequency-selective) and power versus time
high voltage range 1.4 V, peak Full range input level
low voltage range 0.1 V, peak
R&S®CBT-B41 audio generator/analyzer option
AF generator
Output impedance < 4 Ω
Maximum output current 20 mA, peak
AF sinewave generator AF 1 OUT, AF 2 OUT BNC connector
Frequency range 20 Hz to 20 kHz
Frequency uncertainty same as time base + half resolution,
see base unit specifications
Frequency resolution 0.1 Hz
Output level range 10 µV to 5 V
at level < 10 mV 10 µV Output level resolution
at level ≥ 10 mV 0.1 %
Output level uncertainty at level ≥ 1 mV and frequency ≤ 10 kHz ≤ 1.5 % + resolution
THD+N 2 at level ≥ 100 mV into load ≥ 600 Ω ≤ 0.05 %
AF analyzer
Input impedance 1 MΩ || 100 pF
AF voltmeter AF 1 IN, AF 2 IN BNC connector
Frequency range 50 Hz to 20 kHz
Level range 50 µV to 30 V
at level < 1 mV 1 µV Level resolution
at level ≥ 1 mV 0.1 %
at 1 mV ≤ level ≤ 2 V < 1.5 % + resolution Level uncertainty
at 2 V < level ≤ 20 V < 2.0 % + resolution
2
Measurement bandwidth 21.9 kHz.
®
8 Rohde & Schwarz R&S
CBT/R&S®CBT32 Bluetooth® Tester
Version 06.00, April 2009
THD+N meter
Measurement bandwidth 21 kHz
Frequency range 100 Hz to 10 kHz
Level range 10 mV to 30 V
Resolution 0.01 % THD+N
Inherent distortion at 100 mV ≤ level ≤ 20 V < 0.05 % THD+N
at 100 mV ≤ level ≤ 2 V < 1 % + inherent resolution Uncertainty
at 2 V < level ≤ 20 V < 2 % + inherent resolution
R&S®CBT-B42 digital audio interface
S/P-DIF S/P-DIF IN, S/P-DIF OUT in line with IEC 60958-3
Sampling rate 48 kHz
Inputs and outputs (rear panel)
Remote control interfaces
IEC/IEEE bus IEC 60625-2 (IEEE 488.2) 24-pin Amphenol connector
Serial interface COM 1 RS-232-C (COM) 9-pin D-Sub connector
Humidity +40 °C, non-condensing 80 % relative humidity,
Electromagnetic compatibility in line with EMC Directive 89/336/EEC,
Note:
The instrument complies with the emission requirements stipulated by EN 55011 class A. This means that the instrument is suitable
for use in industrial environments. In line with EN 61000-6-4, operation in residential, commercial and business areas or in
small-size companies is not covered.
Thus, the instrument may not be operated in residential, commercial and business areas or in small-size companies, unless
additional measures are taken to ensure that EN 61000-6-3 is complied with.
Electrical safety IEC 61010-1, EN 61010-1, UL 3111-1,
Mechanical resistance non-operating mode
Vibration
sinusoidal in line with EN 60068-2-6, EN 61010-1,
random in line with EN 60068-2-64,
Shock in line with EN 60068-2-27,
in line with EN 60068-2-1 and -2
in line with EN 60068-2-1 and -2
in line with EN 60068-2-78
applied standard: EN 61326
(immunity for industrial environment;
class A emissions)
CAN/CSA-C22.2 No. 1010.1
MIL-T-28800 D class 5,
5 Hz to 150 Hz, max. 2 g at 55 Hz,
55 Hz to 150 Hz, 0.5 g const.
10 Hz to 300 Hz, acceleration 1.2 g rms
MIL-STD-810D, 40 g shock spectrum
Power supplypower factor correction,
in line with EN 61000-3-2
Input 100 V to 240 V ± 10 % (AC), max. 220 VA,
47 Hz to 63 Hz
R&S®CBT approx. 60 W Power consumption
(18.3 in × 3.7 in × 16.4 in)
(19"; 2 height units)
®
CBT approx. 7 kg (15.4 lb) Weight
R&S
®
CBT32 approx. 6 kg (13.2 lb)
R&S
10 Rohde & Schwarz R&S
®
CBT/R&S®CBT32 Bluetooth® Tester
Version 06.00, April 2009
Ordering information
Designation Type Order No.
Bluetooth® Tester with display, 4 HU R&S®CBT 1153.9000.35
Bluetooth® Tester without display, 19", 2 HU, for remote control R&S®CBT32 1153.9000.32
Hardware option for R&S®CBT: Dual-Channel Audio Generator
and Analyzer
Hardware option for R&S®CBT32: Dual-Channel Audio
Generator and Analyzer
Hardware option for R&S®CBT/CBT32: Digital Audio Interface
(S/P-DIF; R&S
Software option for R&S®CBT/CBT32: A2DP Stereo Profile and
SBC Codec (R&S
®
CBT-B41 required)
®
CBT-B41 required)
Software option for R&S®CBT/CBT32: Handsfree and Headset
Profiles
Software option for R&S®CBT/CBT32: Enhanced Data Rate
(EDR)
Software option for the R&S®CBT/CBT32: Bluetooth® Low
Energy Option (Low Energy Non-Signaling Measurements)
19" Adapter, 2 HU, for R&S®CBT32 R&S®ZZA-211 1096.3260.00
19" Adapter, 4 HU, for R&S®CBT R&S®ZZA-S03 1105.6756.00
Documentation of Calibration Values R&S®DCV-1 0240.2187.08
Antenna Coupler for mobile phones R&S®CMU-Z10 1150.0801.10
RF Shielded Cover, extension for R&S®CMU-Z10 R&S®CMU-Z11 1150.1008.02
Bluetooth® Antenna, extension for R&S®CMU-Z10 R&S®CMU-Z12 1150.1043.02
R&S®CBT-B41 1170.3406.05
R&S®CBT-B41 1170.3406.02
®
R&S
CBT-B42 1170.3706.03
®
CBT-K52 1170.4002.02
R&S
R&S®CBT-K54 1170.3806.02
R&S®CBT-K55 1170.3206.02
R&S®CBT-K57 1170.4102.02
Rohde & Schwarz R&S
®
CBT/R&S®CBT32 Bluetooth® Tester 11
Service you can rely on
J Worldwide
J Local and personalized
J Customizedandexible
J Uncompromising quality
J Long-term dependability
About Rohde & Schwarz
Rohde & Schwarz is an independent group of companies
specializing in electronics. It is a leading supplier of solutions in the fields of test and measurement, broadcasting,
radiomonitoring and radiolocation, as well as secure communications. Established 75 years ago, Rohde & Schwarz
has a global presence and a dedicated service network in
over 70 countries. Company headquarters are in Munich,
Germany.
Regional contact
Europe, Africa, Middle East
+49 1805 12 42 42* or +49 89 4129 137 74
customersupport@rohde-schwarz.com
North America
1 888 TEST RSA (1 888 837 87 72)
customer.support@rsa.rohde-schwarz.com
Latin America
+1 410 910 79 88
customersupport.la@rohde-schwarz.com
Asia/Pacific
+65 65 13 04 88
customersupport.asia@rohde-schwarz.com
R&S® is a registered trademark of Rohde & Schwarz GmbH & Co. KG
Trade names are trademarks of the owners | Printed in Germany (ch)
PD 0758.1287.22 | Version 06.00 | April 2009 | R&S®CBT/R&S®CBT32
Subject to change
*0.14 €/min within German wireline network; rates may vary in other
networks (wireline and mobile) and countries.
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.