Atec R3000, R3030 User Manual

Compact designed and manufactured in compliance with
R3000 EMI TEST RECEIVERS
Fully IF digital EMI Receivers family for measurement of electromagnetic interference from 9kHz to 3GHz
CISPR 16-1-1, for measurements of electromagnetic interference in accordance with the requirements of EMI standards such as CISPR, EN 550xx standards, continuously active pre-selectors, advanced software for EMC automation.
R3000 EMI Receivers are PC based microprocessor controlled with advanced software for EMC automation. Fitted with continuously active pre-selectors that allow excellent dynamic range and precise EMC measurements covering the frequency range from 9kHz to 3GHz. These receivers are ideally suited for measurement of electromagnetic interference in accordance with the requirements of CISPR and
EN.
EMI MEASUREMENTS TO STANDARD
MAIN FEATURES
Peak, Quasi-Peak, CISPR Average,
RMS and CISPR RMS
Correct pulse weighting to CISPR
16-1-1 from PRF of 1Hz Optimized easy-to-use EMI measurement concept.
Fitted with the internal pre­selector/ preamplifier all AFJ R3000 models feature an excellent dynamic range and are, therefore, able to perform precise EMC tests.
Measurements to commercial EMI standards such as CISPR, EN 550xx, shall be carried out directly by comparing the EMI spectrum with the associated limit lines and switching on the
appropriate detectors.
High measurement speed and fast
detection of critical frequencies
(dwell time down to 2msec)
EMI measurement bandwidths
200Hz, 9kHz, 120kHz , 1MHz
High sensitivity
Large-signal immunity
Low measurement uncertainty
High measurement speed
Correction values for attenuator /
amplifier cables loss, coupling
networks, GTEM correction and
antenna k factors
Overload indicator
Touch screen display for on site
stand alone usage
CISPR COMPLIANCE
R3000 EMI Receivers fully complies with CISPR 16-1-1 and CISPR 16-1-2. The response of R3000 Quasi­Peak Detector in terms of both
absolute calibration and relative calibration lays between the
tolerances of CISPR 16-1-1. The pulse weighting conformity meets down to the minimum value of the Pulse Repetition Frequency (PRF) coming from the DUT, of 1Hz.
Accuracy and reproducibility are key parameters for AFJ R3000 EMI Receivers application.
R3000 Receiver
Tracking generator
PRE
-
SELECTION FILTERS
DETECTORS
R3000 EMI Receivers are PC-based and totally controlled by easy-running WINDOWS™ software. Software enables the operator to set all parameters and set-up the EMI Receiver as requested by CISPR 16-1-1 or to tailor it according to his specific needs. Some examples are:
Frequency range and frequency step
Detectors (Peak, Quasi Peak, CISPR
Average, RMS, CISPR RMS and combination of them)
Limits set by European and other
Standards
Correction factors
GTEM correction factors
DATA BASE
Receiver settings, measurements set-up, tests and measurements, frequency tables, external devices correction factors are automatically saved into powerful data base according to the proper work spaces defined by the user.
The input bandwidth of the front end is limited by pre-selection filters to reduce the total voltage level at the input mixer to an extent compatible with the wide dynamic range required for quasi-peak detection in the CISPR frequency range.
Up to 15 fixed and tuned pre-selector filters guarantee more than 40dB of attenuation for intermediate frequency, image frequency and intermodulation effects.
Five different types of HW detectors and combinations of them can be selected by the user. In addition to that, each detector type can be associated with a selectable timing, corresponding to the endurance of the measurement aperture gate
.
Touch screen
R3000 Receiver
display for on site stand alone usage
In the Manual Mode, the bar graph, with current detector value and Max Hold display, shows the results of manual circuit adjustment an when DUT cabling is arranged for maximum emission
.