Power Supply
1, Denturi
PS280
CHARACTERISTICS
Two Variable: 0 to 30 VDC One Fixed: 5.0 V
Output Current:
Two Variable: One Fixed
(foldback limited):
Line Regulation:
Two Variable: 0.01% + 3 mV (CV); 0.2% + 3 mA (CC) One Fixed: <
Load Regulation:
Two Variable: <0.01% + 5 mV, current >3 A (CV);
One Fixed: <10 mV (CV)
Ripple/Noise:
Two Variable: <
One Fixed: <
Output in Independent Mode:
Two variable: 0 to 30 V (CV); 2.0 A (CC)
Output in Parallel Mode:
Tracking Error: <
Series Mode:
Tracking Error: ±0.5% +10 mV
Displays:
Voltage Indicators:
Current Indicator: 0 to 2 A DC ±(0.5% of rdg + 2 digits) Overload
Indicator:
Insulation:
Chassis to Terminal:
Chassis to Power Cord:
Safety: UL3111-1, CSA1010.1, EN61010-
300 mV 0 to 60 V single series tracking
<
1 mV
One 0 ±30 V, 2.0 A max or one 60 V, 2 A
Two 3-1/2 digit LED (switchable)
0 to 30 VDC ±(0.5% of rdg + 2 digits)
0 to 2.0 A (CC)*
3.0 A max
5 mV (CV)
supply (CV), 0.2% +3 mA (CC)
, 5 Hz to 1 MHz (CV); <3 mA
RMS
One 0 to 30 V, 4.0 A max
>
20 megaohm at 500 VDC
>
30 megaohm at 500 VDC
(CC)
2 mV
0.5% + 10 mV
Yes
Mark
1
RMS
*1 (CC): When operated in Constant Current mode. (CV): When operated in Constant Voltage mode.