Atec PRO-T User Manual

10 kW Programmable Power Supplies
he PRO-T Series 10 kW program-
T
Features
remote OVP programming and remote shutdown. The PRO-T Series yields 80% efficiencies at full power with good
regulation (<0.1%) and RMS ripple as low as 20 mV.
Voltage
8 models from 0-16 to 0-600 VDC and 16 to 625 ADC,
Input
480 VAC, 50/60 Hz, three phase input (optional inputs available)
SCR Preregulator Topology
Protection and Safety
• Unique circuit prevents load burn-out should remote programming lines open
• OVP shutdown standard
• SCR crowbar (Option M5)
Remote Programming
• Remote control functions: voltage, current, OVP shutdown, external meter/indicator driver
• No programming resistors in contact with output, avoids high voltage problems with programming components
• Optional Internal IEEE-488/RS 232 Interface Card with voltage and current readback and adjustable OVP (Option M9C)
Regulation
0.1% line and load regulation (max.)
Programming
Fast programming speed (100 to 150 ms typical)
Rear Panel Controls
Rear panel connector features: AC control, shutdown, voltage set, OVP set, local/remote current meter, remote voltage meter, OVP indication, thermal indication and remote sense.
Software
LabVIEW® driver for M9C/M85 can be downloaded at no cost at www.sorensen.com/support/ downloads.cfm
CE Mark
(Option M36)
5 Year Warranty
Sorensen • 858/450-0085 • 800/733-5427 • Fax: 858/458-0267 • 9250 Brown Deer Road • San Diego • California • 92121-2294 • www.elgar.com • E-mail: sales@elgar.com
23
OUTPUT
Voltage: See table Current: See table
Constant Voltage Mode
Noise and Ripple: See table Regulation Line and Load Combined: 0.1% of the
voltage setting or specification in table, whichever is greater
Transient Response: Typically recovers in
40 ms to within 1% of steady-state output voltage for a 50% to 100% or 100% to 50% load change
Stability: 0.1% of maximum voltage over
8 hours after 30 minute warm up time at fixed line, load and temperature
Temperature Coefficient: 0.02%/°C of
maximum output voltage
Constant Current Mode
Ripple: See table Regulation Line and Load Combined: 0.1% I0 max. of
the output current setting or specification in table, whichever is greater
Stability: 0.1% of maximum current over 8
hours after 30 minute warm-up time at fixed line, load and temperature
Temperature Coefficient: 0.04%/°C of
maximum output current
INPUT
Voltage and Frequency: 480 VAC ± 10%,
50-60 Hz, three phase
Voltage Options: See Input Voltage Options Current: See table
GENERAL
Operating Temperature: 0° to 50°C
(derated above 30°C)
Storage Temperature: -45°C to 85°C Cooling: Forced air, fan cooled Humidity Range: 0-90% RH,
non condensing
Efficiency: 80% at full rated output (typical) Series Operation: 200 VDC max.; consult
Sorensen for series operation of more than 2 units
Parallel Operation: Master/slave operation
up to 3 units. Consult factory for details.
Overvoltage Protection: Adjustable
5-110% of rated output. Selectable front panel or remotely programmable
Meter Accuracy: 1% of full scale + 1 count Voltage Programming: 100 mV per 1% of
rated output (0-10 V for 0-100% of rated output)
Current Programming: 100 mV per 1% of
rated output. (0-10V for 0-100% of rated output)
Resistive Programming: 100per 1% of
rated output (0-10 kfor 0-100% of rated output)
Remote Sense: 5V max. drop in
(+) power lead or (-) power lead
Software: LabVIEW® driver for M9C/M85,
programs can be downloaded at no cost at www.sorensen.com/support/downloads.cfm
Regulatory Compliance: CE Mark
(<300V models only)
Dimensions: 7U or 12.25” (311 mm) H x
19” (482 mm) W x 24” (609 mm) D
Weight: 310 lbs. (141 kg) Shipping Weight: 380 lbs. (172 kg)
OPTIONS & ACCESSORIES
M5: SCR crowbar M9C: Internal IEEE-488/RS 232 Interface M36: CE Mark (<300V models only) M85: Multichannel slave interface M86: Parallel cable
Input Voltage Options
Specifying Note: Select AC input voltage option below and add as a part number suffix to specify power supplies (listed as 50-60 Hz, three phase)
T1: 208 VAC T5: 480 VAC T2: 380 VAC T8: 220 VAC T3: 415 VAC T10: 230 VAC T4: 440 VAC T11: 400 VAC
PRO-T Accessories
Caster Cart Kit: Part No. 1064395-1
Sorensen • 858/450-0085 • 800/733-5427 • Fax: 858/458-0267 • 9250 Brown Deer Road • San Diego • California • 92121-2294 • www.elgar.com • E-mail: sales@elgar.com