Atec PowerStar User Manual

The Simplex PowerStar Portable Load Bank is an ultra-compact, lightweight, versatile test instrument specially designed for manufacturers, dealers and users of small AC power systems, to 110KW nominal. It is suitable for testing engine generators, wind generators, UPS systems, ground power units, auxiliary power units, static inverters or virtually any other AC power source on the production line, in the service shop or in the fi eld. It can be applied at all common AC voltages to 480V maximum, 50-60 Hertz, single or 3-phase.
The Powerstar is a digitally controlled load bank with network capability. All control is via a hand-held touchscreen controller connected to the load bank via a supplied RS-232 network cable. The load bank includes a digital power transducer with meter displays on the touchscreen. Load is applied via a screen keypad. Any number of Powerstar Load Banks can be networked together via RS-232 cables connected from the “out” connector on the fi rst unit to the “in” connector on the next, and then “out-to-in” in succession until the desired number of units are connected. All control and metering is provided from a single hand-held controller. All instrumentation values for the total network are summed and displayed on the master controller.
The PowerStar is highly portable and easily transported to the job site. The Load Bank includes casters, lifting and moving handles. Power connections are plug-in to Cam-Lok connectors. Control and cooling fan power is obtained from a common 115v, 15A outlet via the included connection cord.
The PowerStar is a fully self-contained and portable testing system. It includes integral cooling fans and control circuits, which can operate from a supplied 120V control power cord.
LISTED
PowerStar-110
Features
• New: Increased capacity to 110KW
• UL Listed, United States and Canada
• Lightweight and compact
• Portable, self-contained
• “Powr-Web” elements
• Branch circuit fuse protection of load elements
• Magnetic contactor control of load
• Digital load control
• Use at all common 50 or 60 Hertz voltages, to 480V AC
• Digital Power Transducer, standard: Volts, Amps, Frequency, Kw
• 150°C XLP insulated power wiring
• Cam-Lok power connectors
• Operate fan and control circuits from a common 120V wall outlet, 15’ cord provided
110 KW Digital Load Bank
with Network Capability
• Forced air cooled, integral cooling fans
• Fan motors protected by fuses
• Control circuits fused
• Comprehensive malfunction detection system:
- Overtemperature and fan failure
protection
- Overvoltage protection
• Continuous duty
• NEMA-1 enclosure
• Casters and handles provided
Insight
Onsite
®
PowerStar-110
110 KW Digital Load Bank with Network Capability • Page 2
Dimensions and Key Features
1. Control Compartment Cooling Fans (2)
2. Load Element Compartment Cooling Fans (4)
3. Load Source Connections
4. Storage Compartment for handheld controller
5. Handles (2)
6. RS-232 and 120V connectors
7. Swivel Casters (4)
®
LISTED
Capacity Detail
FLA KW DETAIL
Model
PowerStar 264 132 110 82.5 73.3
Fan/Control Power
External, 115V, 1-ph., 60Hz, 15A service, 15’ cord with plug provided
240V 480V 240V/480V 208/416V 240V, 1-ph
Frequency
50–60Hz
Duty Cycle
Voltage
Dual Voltage, nominal 240/480V AC, 3-phase
208-240/416-480V AC, 3-phase, 60Hz
190-220/380-460V AC, 3-phase, 50Hz
110-240V AC, 1-phase, 50-60Hz
Load Steps
Digital load control, 5kw resolution
Continuous
Temp Rating
125° F max intake air temp
Nominal 110° F rise
Weight
125 lbs.
Options
• Vinyl Cover
• Shipping / Storage Container
in Atlanta, GA.
Simplex, Inc. 5300 Rising Moon Road Springfi eld, IL 62711-6228
217-483-1600 Fax 217-483-1616 www.simplexdirect.com
© 2013 Simplex, Inc. All Rights Reserved. Printed in the USA • 1012-08.03 Design subject to change without notice.