Regenerative DC Electronic Load
NEW
Regenerative DC Electronic Load
PLZ6000R
No necessity of special cooling system such as water cooling method
Voltage/current/power range: 30 V - 400 A / 60 V - 200 A / 6 kW
Power regeneration effi ciency of up to 90% or more!
Six load modes (CC/CR/CV/CP/CC+CV/CR+CV)
Easy-to-use design featuring a large-size LCD panel
Equipped with major interfaces (GPIB, RS-232C, and USB) as standard

Regenerative Electronic Load
Environment-friendly DC electronic load of the power line regeneration type
Capable of regenerating power with clean current waveforms
Compact size
430 mm (W) × 173 mm (H) × 550 mm (D)
16.93 W × 6.81 H × 21.65 D inches
Regenerative DC Electronic Load
PLZ6000R
Power regeneration
effi ciency of up to 90%
Large capacity
6
kW
NEW
PLZ6000R is a DC electronic load that regenerates load power to the AC line.
Regular electronic loads consume load power by having semiconductor devices convert it into heat. By
contrast, PLZ6000R converts load power into reusable electric power, rather than converting it into heat as is
typically done, and feeds this power to the AC line, thereby substantially reducing the amount of waste energy.
PLZ6000R is an environment-friendly electronic load that can contribute signifi cantly to your energy saving
efforts.
Applications
Aging and evaluation testing for DC/DC converters and various types of power
supplies
Evaluation and durability testing for alternators and motor generators
Discharge testing for different types of batteries (lead, lithium, and assembled
batteries)
Dummy load testing for equipment powered by natural energy (solar cells and
wind power generation)
Evaluation testing for fuel cells and stacks
[Note] This product is intended for in-plant power generation only. (It does not feed its generated power back to the electric power
system.)
This product cannot be used unless 5.4 kW or more of power is consumed by each power distribution system per one unit.

Functions
Power regeneration efficiency of up to 90%
(at rated power)
The use of a proprietary switching technology (patent pending)
provides high power regeneration efficiency - from 85% or
more at one-third of rated power (2000 W) to a maximum of
90% or more.
This energy saving feature greatly reduces the electronic
load's environment impact on your plant and it is not necessary
to equip special cooling system such as water cooling method
to supress the heat generation.
Regeneration efficiency of PLZ6000R
Regeneration efficiency [%]
Load power [W]
Regenerated power values recognizable at a
glance!
The large-size LCD panel displays regenerated power values
in real time.
This makes the energy saving effect much easier to recognize.
30V-400A
200.00A 30.000V
SET
OCP
0.1500S
6.6666
220.00A
OPP
C . R
6600.0w
TIME:000: 00: 00
ACpwr
-30.8 Wh
R
6000.0W
-5.3kW
k
Soft start function
In constant current (CC) mode, this function causes the load
current to rise gradually when the initial load is at 0 V while the
load of the load unit is on or when the load of the load unit is
turned on. It allows you to conduct tests under highly realistic
load conditions.
[The soft start time can be selected from the following options 20, 50, 100, and 200 ms.]
Output voltage of the DC power supply
Input current of the electronic load
Time
Output voltage
0
Time
Output voltage
0
When the soft start function is not used When the soft start function is used
Sequence function
This function automatically executes arbitrarily set sequence
patterns step by step (operation by operation). It enables
various types of waveforms to be simulated. (A maximum of 10
programs can be created, each consisting of up to 256 steps.
Operation modes, ranges, loop counts, etc. can be specifi ed in
these programs.)
7 A
Step 3Step 1 Step 2
Input current
100 seconds
RAMP ON (ramp)
7 A
150 seconds
RAMP OFF (step)
7 A
80 seconds
RAMP ON (ramp)
0.5 A
Time
The current regenerated power value is shown in the upper row of the section, while
the accumulated regenerated power value is presented in a larger font in the lower row.
(The minus (-) sign indicates power regenerated.)
Auto load off timer function
This function automatically turns off the load current; it is
useful for discharge tests of batteries and other devices.
• Measurement of the time elapsed from the start of discharge
until the fi nal voltage (UVP) is detected (elapsed time display)
• Measurement of the closed circuit voltage after the specifi ed
time elapses from the start of discharge (auto load off timer)
Voltage
V2: Voltage after the specified time elapses
V2
V1
0
Tcutoff Tcount
V1: Voltage when UVP is detected
Tcount: Elapsed time indicator (Count Time)
Tcutoff: Auto load off timer (Cut Off Time)
Time
Parallel operation supporting up to 30 kW
A large-capacity system of up to 30 kW can be built using a
parallel connection confi guration with one control unit. (The
system may consist of up to fi ve units - one master unit and
four slave units.)
ABC preset memories
Three preset memories A, B, and C are provided to store and
read up to three different combinations of an operation mode, a
range, and set values.
Equipped with major interfaces
GPIB, RS-232C, and USB interfaces are equipped as standard,
making it easy to integrate the electronic load into a variety of
testing systems.
Support for these interfaces, coupled with the sequence
function, allows you to build diverse types of system.
(The SCPI commands are adopted.)

Specifi cations
Rating
Operating voltage (DC)
Current
Power 6000 W
Constant Current (CC) mode
Operating range
Setting range
Resolution 10 mA
Setting accuracy ± (0.4% of set + 400 mA)
Input voltage variation 400 mA
Ripple
Constant Resistance (CR) mode
Operating range
Setting range
Setting accuracy ± (0.5% of set* + 2 A) *set = Vin/Rset
Constant Voltage (CV) mode
Operating range
Setting range
Resolution 1 mV
Setting accuracy ± (0.1% of set + 60 mV)
Input current variation 12 mV
Constant Power (CP) mode
Operating range 0 W to 6000 W
Setting range 0 W to 6300 W
Resolution 0.1 W
Setting accuracy ± (1% of set + 60 W)
Voltmeter
Display 0.000 V to 60.000 V
Resolution 0.002 V
Accuracy ± (0.1% of reading + 60 mV)
Ammeter
Display 0.00 A to 400.00 A
Resolution 0.01 A
Accuracy ± (0.3% of reading + 300 mA)
Wattmeter
Display 0.0 W to 6000.0 W
Resolution 0.1 W
30 V range 3 V to 30 V
60 V range 6 V to 60 V
30 V range 400 A
60 V range 200 A
30 V range 0 A to 400 A
60 V range 0 A to 200 A
30 V range 0 A to 408 A
60 V range 0 A to 204 A
rms 500 mA
p-p 2 A
30 V range
60 V range
30 V range
60 V range
134 S to 2.5 mS
(7.4627 mΩ to 400 Ω)
34S to 2.5 mS
(29.412 mΩ to 400 Ω)
136 S to 0 S
(7.3529 mΩ to OPEN)
34 S to 0 S
(29.412 mΩ to OPEN)
30 V range 3 V to 30 V
60 V range 6 V to 60 V
30 V range 3 V to 30 V
60 V range 6 V to 60 V
Protection function
DC side
Overvoltage protection (OVP), Overcurrent protection (OCP), Overpower protection (OPP),
Overheat protection (OHP), Reverse connection protection (REV), Undervoltage protection (UVP)
Voltage range error (outside the 170 V-240 V range)
AC side
Frequency range error (outside the 45 Hz-65 Hz range)
Open phase (when one of the three phases is missing)
Soft start
Operation mode CC mode
Selectable time range 20 ms, 50ms, 100 ms, 200 ms
Time accuracy ± (30% of set + 100 μs)
Remote sensing
Compensation voltage 2 V for a single line (The sensing line is switched by a relay.)
Sequence function
Operation mode CC, CR, CV, CP
Maximum number of steps 256
Step execution time 10 ms to 999 h 59 min
Resolution 10 ms to 1 min
Other functions
Elapsed time display
Auto load off timer
Communication interface
Measures the time from load on to load off.
Can be set in the range of 1 s to 999 h 59 min 59 s or off.
Automatically turns off the load after a specifi ed time elapses.
Can be set in the range of 1 s to 999 h 59 min 59 s or off.
GPIB, RS-232C, and USB interfaces are equipped as standard.
External voltage (0 to 10 V): CC/CR/CP control
External voltage (0 to 10 V): CV control
External resistance (0 to 10 kΩ): CC/CR/CP control
External controls
(J1 connector on the rear
panel)
External resistance (0 to 10 kΩ): CV control
LOAD ON.OFF
Range selection
Mode selection
TTL level signal
Preset memory A/B/C
Trigger input Pause cancellation (TTL)
Monitor signal output
V MON (voltage) 5 V f.s (30 V range) /10 V f.s (60 V range)
I MON (current) 10 V f.s (30 V range) /5 V f.s (60 V range)
LOAD ON status On when the load is on.
Status signal output
ALARM status On when an alarm processing is in progress.
RANGE status On when the 30 V range is selected.
Trigger signal output TRIG OUT; BNC terminal on the front side (approx. 4.5 V, 1 ms wide)
General specifi cations
Input voltage range AC180 V to 220 V (3-phase 3-wire)
Input frequency range 47 Hz to 63 Hz
Power consumption 200 VA (when no load is input)
Maximum regenerated power 5600 VA
Power regeneration effi ciency 85% or more
Dimensions
Width: 430 mm (16.93") / Height: 173 mm (6.81") / Depth: 550 mm (21.65")
Weight Approx. 43 kg (94.8 lbs.)
Accessories Manual, DC input terminal covers, etc.
4047040
Dimensions
(mm)
4-M4 screw holes (maximum depth: 6 mm)
5050
Options
303
Description Model name Specifi cation
Power cable AC8-4P4M-M6C 3-phase, 4-core, 8mm2-wide M6 cable
Parallel operation cable PC01-PLZ-4W Flat cable about 300 mm long
Rack mounting bracket
Printed in Japan Issue:Jun.2011 201106PDFEC21
KRB4 EIA (inch)
KRB200 JIS (millimeter)
1-877-876-2807
www.kikusuiamerica.com
530 Lakeside Drive, Suite#180, Sunnyvale, CA 94085, U.S.A.
Phone : 408-733-3432 Facsimile : 408-733-1814
www.kikusui.cn
Room, D-01,11F, Majesty Bld, No.138, Pudong Ave, Shanghai Cit
Phone : 021-5887-9067 Facsimile : 021-5887-9069
Distributor:
■
All products contained in this catalogue are equipment and devices that are premised on use under the supervision
■
of qualifi ed personnel, and are not designed or produced for home-use or use by general consumers.
design and so forth are subject to change without prior notice to improve the quality.
subject to change and production may be discontinued when necessary.
brand names contained in this catalogue represent the respective registered trade name or trade mark.
textures and so forth of photographs shown in this catalogue may differ from actual products due to a limited fi delity in
printing.
Although every effort has been made to provide the information as accurate as possible for this catalogue,
■
certain details have unavoidably been omitted due to limitations in space.
catalogue, it would be appreciated if you would inform us.
price, accessories or anything that may be unclear when placing an order or concluding a purchasing agreement.
430
MAX20
32.5
3111527
173
MAX195
4-M4 screw holes including those on the opposite side (maximum depth: 12 mm)
MAX665
550
Specifi cations,
■
Product names and prices are
■
Product names, company names and
■
If you fi nd any misprints or errors in this
■
Please contact our distributors to confi rm specifi cations,
■
■
Colors,