LOOP ANTENNAS
ARA TECH offers two different models (ALA-130/A and ALA-
1030/B) of active loop antennas, three different models (PLA130/A, PLA-1030/B, and PLA-205/B) of passive loop
antennas, and two different pairs (PLA-2050 & PLH-2050 and
PLA-451 & PLH-450) of loop sensors or field pick up coils and
radiating loops.
The PLA-130/A and ALA-130/RS are designed for the
shielded room testing requirements per MIL-STD 285 and NSA
test standard 65-6. The PLA-130/RS is capable of handling 1
kW input power while the ALA-130/RS provides the dynamic
range required for shield room attenuation measurements. The
ALA-130/RS and PLA-130/A are sold together as a set known
as the APL-130/RS.
The PLA-1030/B is a single band passive loop antenna for
immunity or emission testing.
The PLA-205/B is optimized for generating fields in the low
end of the frequency band from 20 Hz to 5 MHz. It can also be
used for emission testing at low frequencies. When used with
our extremely sensitive BBH series receive antennas, it
provides the best combination for testing shielding
effectiveness in the 20 Hz to 5 MHz band.
PLA-130/A
All loop calibrations are made relative to a 50 ohm load. Active
and passive loops (except field generating coils PLH-450 and
PLH-2050 and field pick-up coils PLA-2050 and PLA-451) are
individually calibrated in accordance with procedures specified
in IEEE-291 section 2.3.1.
SPECIFICATIONS
ALA - 130/RS
ALA - 1030/RS
PLA - 130/A
PLA - 205/B
PLA - 1030/B
PLA - 2050/A
PLH - 2050/A
Options
FREQUENCY
RANGE
1 kHz - 30 MHz N/A 50 ohm 12" dia 6" x 4" BNC Female Active
10 kHz - 30 MHz N/A 50 ohm 24"x24" 6" x 4" BNC Female Active
1 kHz - 30 MHz 1 kW 50 ohm 12" dia 6" x 4" N Female Passive
20 Hz - 5 MHz 5 Watts 50 ohm 24"x24" 4" x 3" BNC Female Passive
10 kHz - 30 MHz 5 Watts 50 ohm 24"x24" 6" dia BNC Female Passive
20 Hz - 100 kHz N/A N/A 5.2" dia 3" x 2.5" BNC Female Passive
20 Hz - 100 kHz 5 Amps N/A 4.7" dia 4.7" dia Banana Jack Passive
INPUT
POWER
IMPEDANCE SIZE CONNECTOR TYPE
ALA-130/RS
LOOP BASE
1. 10-foot RF cable with ferrite sleeves 3) Carrying Case
2. Tripod, TP-5 or TP-3
40
Phone: 301-937-9381 zzzz Fax: 301-937-2796 zzzz http://www.aratech-inc.com zzzz emc@aratech-inc.com
LOOP ANTENNAS
ALA-130/A
Typical H-field Antenna Factor
Frequency AFH
(dB AV-1m-1)
(Minimum detectable H-Field, MDF)
(Referenced to 1 kHz Bandwidth)
Frequency MDF
ALA-130/A
Typical Sensitivity
(dB
µ
A/m)
PLA-1030/B
Typical H-Field Antenna
Factor
Frequency AFH
(dB AV-1m-1)
1 kHz 5.5 1 kHz 26.9 10 kHz 39.4
3 kHz -3.0 3 kHz 15.8 30 kHz 29.2
10 kHz -14.5 10 kHz 4.1 50 kHz 24.6
30 kHz -24.9 30 kHz -7.9 80 kHz 20.0
50 kHz -29.2 50 kHz -13.4 100 kHz 18.2
80 kHz -34.1 80 kHz -17.4 200 kHz 12.0
100 kHz -35.7 100 kHz -19.6 500 kHz 4.2
200 kHz -41.4 200 kHz -25.2 700 kHz 1.2
500 kHz -48.6 500 kHz -32.4 1 MHz -1.6
700 kHz -51.0 700 kHz -35.4 2 MHz -8.1
1 MHz -55.7 1 MHz -39.2 3 MHz -11.3
2 MHz -61.5 2 MHz -43.8 6 MHz
3 MHz -64.7 3 MHz -45.3 10 MHz
6 MHz -65.9 6 MHz -48.4 20 MHz
10 MHz -62.8 10 MHz -50.6 30 MHz
20 MHz -54.4 20 MHz -49.5 40 MHz
30 MHz -50.1 30 MHz -49.4 50 MHz
-16.9
-19.5
-20.2
-19.6
-19.0
-19.3
PLA-205/B
Typical H-field Antenna Factor
Frequency AFH
(dB AV-1m-1)
Frequency AFH
PLA-130/A
Typical H-Field Antenna
Factor
(dB AV-1m-1)
100 Hz 68.5 Lo-Band
200 Hz 64.6 1 kHz 56.5
330 Hz 60.9 3 kHz 46.7
400 Hz 59.4 10 kHz 36.0
600 Hz 55.7 30 kHz 25.5
1 kHz 49.6 50 kHz 21.1
3 kHz 36.5 80 kHz 16.4
10 kHz 22.5 100 kHz 14.7
30 kHz 12.0 200 kHz 8.7
50 kHz 6.9 500 kHz 2.8
80 kHz 3.0 700 kHz 1.0
100 kHz 1.3 1 MHz .2
200 kHz -3.9 2 MHz -1.4
500 kHz -6.5 3 MHz -1.6
700 kHz -6.9 Hi-Band
1 MHz -7.2 1 MHz
2 MHz -8.1 2 MHz
3 MHz -8.4 3 MHz
5 MHz -8.4 6 MHz
PLA-205/B
10 MHz
20 MHz
30 MHz
-10.6
-12.7
-14.2
-14.7
6.0
-.3
-3.9