PIM 400, PIM 410
PCD430 UL 1449 IMPULSE TEST SYSTEM
To be used for transient voltage surge
suppressor testing of:
n Surge Current Tests
n Transient Voltage Surge
n Duty Cycle.
Using combination wave impulses for 50 and
60Hz power circuit applications.
Transient Voltage Surge Suppressors are fitted
on the load side of domestic and commercial
power outlets to protect electrical and electronic
equipment from the effects of lightning surge
pulses.
Applications are for the testing of single and
three phase protection devices of the following
categories:
n Permanently connected
n Cord connected
n Direct plug-In
A suitable CDN is required as the tests are
performed with the TVSS energized
Top-down: Controller, PIM 110, PIM 400 & PIM 410
impulse modules, PCD430 coupling network
ONE SOLUTION for : þ UL 1449 Table B1.1 (Appendix B)
þ add a PIM 110 for full ANSI C62.41
FEATURES
n Impulse voltage up to 7kV
n 3000A impulse (2 ohm)
n 500A impulse (12 ohm)
n 100kHz Ring wave (12 & 30 ohm)
n Oscilloscope Impulse monitors
n 10s impulse repetition @ 6kV
n Automatic polarity switching
n Automatic impulse switching
n 32A 3 phase CDN @ 600V/60Hz
n impulse defined at CDN output
n allowable fault current > 200A
n synchronization with each phase
BENEFITS
n Fully automatic waveform switching
n Reproducible and reliable test results
n Fault current through CDN > 200A
n Remote control using WinFEAT&R
n Supplied to ISO 9001
TECHNICAL
EXCELLENCE
EASY OPERATION SAFETY & QUALITY
e.g. accurate, clean pulses
PIM400,410/PCD430
modules are fully compliant
to UL 1449 requirements.
n System can be configured
for UL and ANSI testing.
n Impulse parameters
guaranteed at CDN output.
n Automatic impulse type
switching during testing.
n Highly accurate and
reliable semiconductor
discharge switch places the
pulse at the selected angle on
the selected phase.
UL 1449 requires
synchronization of the surge
impulse with the test phase.
Haefelys’ Surge Platform
solution switches the
synchronization source
automatically between
phases.
UL 1449 test system can
be assembled into a rack or
used as separate bench
standing units. The
advantage of this
architecture is that the test
equipment can be tailored
to fit in your application,
not the other way around.
A built-in Micro processor is
the user interface and
controls:
n Test/Program setup
n System configuration
n Peak Voltage monitoring
n Test Log file printing
Operating the UL 1449
system, from WinFEAT&R
Software opens additional
possibilities such as:
n EUT failed limits control
n Automatic Test
reporting in MS Word™
format
n EUT monitoring during
testing
n Pre programmed test
routines.
Designed as an
expandable system,
Modules can be used
either
n in a desktop
configuration or
n rack mounted with
other system modules.
All EUT connections are
on the unit front panels
providing a clean
separation between test
instrument and EUT
connections.
A full range of accessories
is available to provide
safe and easy connections
with the test object.
The unit is designed
according to EMC and LV
directives.
UL 1449 system is
supplied with an
additional high-visibility
warning lamp.
Access to all operational
high voltage and AC
power circuits is safety
interlock protected.
All Haefely EMC products
carry a two year
manufacturers warranty.
TECHNICAL SPECIFICATION
PIM 400/410 PCD 430
Impulse Voltage 0.50kV ... 7.0 kV EUT AC Voltage 690V (phase-phase)
Impulse Repetition 5 ... 10 seconds @ 6kV EUT AC Current 32A per phase
Voltage Waveform Risetime 1.2µs Backtime 50µs Overcurrent protection 32A in all phases
Current Waveform Risetime 8µs Backtime 20µs Synchronisation with coupling phase
Impulse Impedance 2 ohm & 12 ohm
ORDERING INFORMATION
PSURGE 8000 Controller 249 900
PIM 400 Impulse Module 249 946
PIM 410 Impulse Module 249 947
PCD 430 Coupler/Decoupler 249 948
PIM 110 Impulse Module 249 903
WinFEAT&R Software 249 700
Issue 01/02
Haefely Test AG
Business Unit EMC
Lehenmattstrasse 353, P.O Box
CH-4028 Basel
Switzerland
Phone: ++ 41 61 373 41 11
Fax: ++ 41 61 373 45 99
email: EMCsales@haefely.com