Atec PCR500 User Manual

Page 1
Internet
/
http://www.kikusui.co.jp
Compact AC Power Supply
PCR-M Series
Compact AC power supply using the PWM inverter method
Output capacity: 500 VA, 1,000 VA and 2,000VA (single phase)
AC output: 1 V to 135 V/2 V to 270 V at 40 Hz to 500 Hz
DC output: ±1.4 V to 190 V/±2.8 V to 380 V
The maximum peak current triples the rated current (RMS value).
Equipped with measurement functions and various communication interface options.
Page 2
Introducing a Compact AC Power Supply That is Ready to Use
The PCR-M series is a small-size AC power supply with the ease of a variable auto transformer or an automatic voltage regulator (AVR) and the usefulness of a multifunctional AC power supply. As the PWM inverter method is adopted for the power unit, the PCR-M series is much smaller and lighter than the predecessors while enabling high-quality and highly-effi cient (about 70%) operation. This power supply comes with measurement features, memory feature, protection functions and various communication interface options, and it is even possible to provide DC power. When you incorporate an optional analog interface board (EXO4-PCR-M), the PCR-M series can also be used as a booster for arbitrary signal generator. This small and versatile unit can provide you with more work styles than you can imagine. You can't do without it once you use it!
Versatile output modesCompact design
Small enough to fi t on your work desk! Only 214W × 124H × 350D mm! Weighs only 6 kg and easy to carry! (PCR500M)
Neatly fi ts on your desk!
(Picture) Left: PCR500M Right: Electronic Load PLZ164W
Easy remote control with attached software!
Small and light. Only 6 kg
(PCR500M)
Three modes (AC, DC, AC+DC) are available. The frequency range is up to 500 Hz.
*1
Memory function
You can store and recall three combinations of settings for voltage, frequency and limits for the output on the main unit. By calling the memory during output, you can test the sudden changes of voltage or frequency.
*2
Measurement functions
You can measure the voltage, current and power of AC and DC output, apparent power, reactive power, power factor, crest factor and current peak hold.
*3
Various communication interface options
RS-232C is provided as standard. GPIB and USB are optional.
Analog interface
By incorporating an optional analog interface (EXO4-PCR-M), output can be controlled by using external analog signals. Input DC signals can be used to change output AC voltage and boost input waveform.
Easy to carry with only one hand
Compact AC Power Supply
1 You can access AC+DC mode if you have installed an optional interface board of
*
IB21, US21 or EX04-PCR-M. The communications interface is used to set that mode.
2 An installed appropriate optional interface board allows up to ten combinations of
*
settings to be stored in the memory. The communications interface is also used to set or call extended memory addresses (4 to 10).
3 You can use the communications interface to measure apparent power (VA),
*
reactive power (VAR), power factor (PF), crest factor (CF), and peak hold current.
Page 3
Performance and Features
Recalled memory A
Recalled memory B
Recalled memory A
Recalled memory B
Sudden changes of voltage
Sudden changes of frequency
Amplifier
Output
Input
100 Vrms AC Sine wave or 200 Vrms AC Sine wave
1 Vrms AC Sine wave
Example:
Range of phase angle setting: 0 to 359 degrees.
Output on Output on phase angle is set at config.
Output off The output is turned off at a next zero cross phase.
Amplifier
Sine wave 10 V
Input
Output
0 V to 135 V AC or 0 V to 270 V AC
Input DC voltage 0 to 10 V
Example:
COMPACT AC POWER SUPPLY
Compact design
The PCR-M series is characterized by much smaller size and lighter weight in comparison with the ac power supply based on the linear amplifi er. For example, the very compact PCR-M series is reduced by a factor of 5 in terms of the volume and by a factor of about 4 in terms of the weight (in comparison with our past product). You can readily handle this product on your desk and easily carry it.
Output characteristics: AC mode
The output voltage varies from 1 V to 135 V or 2 V to 270 V (two ranges). You can switch ranges manually or automatically. The peak current can triple the maximum rated current for the rectifi er load of the capacitor input type. The frequency varies from 40 Hz to 500 Hz, which is why the PCR500M is suitable as a power supply for aircrafts and ships that require 400 Hz and for driving actuators that require 250 Hz.
High-quality output waveform (distortion rate of output waveform is 0.5% or less)
Output characteristics: DC mode
The output voltage varies from ±1.4 V to 190 V or ±2.8 V to 380 V (two ranges). You can switch ranges manually or automatically. The maximum instantaneous current is up to three times higher than the maximum rated current. When an optional interface board is installed, the direct current can be superposed on the alternating current (AD + DC mode)
*1
Output on phase angle
The output on phase angle can be set at AC mode. The output off phase angle is turned off at a zero cross phase.
Memory function
*2
The PCR-M series can store three sets of setting value for output voltage and frequency, and limit value. By manually changing the preset memory during output, the test for sudden changes of voltage and frequency is also possible. When an optional interface board (IB21, US21 or EX04­PCR-M) is installed, the memory can store up to 10 settings.
Analog interface
By using an optional analog interface board (EX04-PCR-M), you can control the output by external analog signals.
EXT-AC mode
The voltage of the output alternating current can be changed based on the level input DC signal.
Control using a PC
You can control the PCR-M series through the standard RS-232C interface, the optional GPIB interface, or the optional USB interface. the control software (Easy Controller for PCR-M
By using
*
series) which comes with the PCR-M series, you can easily set the parameters of the PCR-M series and log the output measured values.
Operating environment for Easy Controller for PCR-M
• OS: Windows XP/2000/Me/98
• CPU: Pentium 233 MHz or greater
• Memory: At least 128 MB
• Driver: VISA library supporting VISA COM
• Interface: RS-232C, GPIB, or USB
Instrument drivers for Microsoft Visual Basic,
*
Microsoft Office VBA, Microsoft Visual C++, LabVIEW, or LabWindows/CVI are also included in the disc.
Options
GPIB interface board: IB21
USB interface board: US21
Analog interface board: EX04-PCR-M
Input characteristics
The input voltage is from 100 V AC to 120 V AC or 200 V AC to 240 V AC at 50 Hz/60 Hz (single phase). The voltage is automatically determined when the power supply is turned on. The active filter enables the power factor to be 0.9 (TYP value) to reduce the input current and the harmonic current.
Measurement functions
*3
The PCR-M series can measure the voltage, current, and power of AC and DC output. The device can display the true RMS and the average (DC) values for the output voltage, and the true RMS, peak and the average (DC) values for the output current. When a communication interface is used, the PCR-M series can measure the apparent power (VA), the reactive power (VAR), the power factor (PF), the crest factor (CF), and the peak hold current.
Protection
The following protection features are available:
• Protection against non-rated input voltage
• Protection against overheat (OHP)
• Protection against overload: Current limit (OCP)/monitoring for exceeded power (OPP)/monitoring for exceeded peak current
• Detection of voltage abnormalities: Increased voltage (OVP)/decreased voltage (LVP)
Voltage amplifi cation rate: 13.5-times or 27-times
EXT-DC mode
The input waveform is directly amplified and output.
Voltage amplifi cation rate: 100-times or 200-times
IB21 US21 EX04-PCR-M
Note: Only one interface board can be installed.
Rack mount adapters
For the PCR500M KRA150 (for millimeter specifi cations) KRA3 (for inch specifi cations)
For the PCR1000M and PCR2000M KRB150-TOS KRB3-TOS (for inch specifi cations)
Rear panel
(for millimeter specifi cations)
PCR500M
PCR1000M
PCR2000M
Page 4
Specifi cations
y
Specifi cations of the main unit Note: “TYP value” indicates a typical value and does not guarantee the performance. "rdng" indicates a reading on the device.
PCR500M PCR1000M PCR2000M
Input voltage
Input current Input power factor Effi ciency
Output voltage
Setting Resolution
Output capacity
Maximum current
Output frequency Output waveform distortion ratio
Accuracy of voltmeter
Accuracy of ammeter (RMS)
Dimensions (maximum) Weight Operating temperature
and humidity range Storage temperature and
humidity range
*1
When the output voltage is 100 V/200 V (in the 135 V/270 V range), the current is maximum, and the load power factor is 1.
*2
When the output voltage is 1 V to 100 V/2 V to 200 V. Depends on the power capacity when the output voltage is 100 V to 135 V/200 V to 270 V.
*3
When the output voltage is 1.4 V to 100 V/2.8 V to 200. Depends on the power capacity when the output voltage is 100 V to 190 V/200 V to 380 V.
Specifi cations of the communication interface
RS-232C
GPIB (IB21: optional)
USB (US21: optional)
Common
Nominal rated input: 100 to 120 V AC/200 to 240 V AC, 50/60 Hz, single phase Input voltage range: 90 to 132 V AC/180 to 250 V AC (automatically determined when the power
Up to 9 A/4.5 A Up to 18 A/9 A Up to 36A/18 A
1
*
0.9 (TYP value)
is turned on), 47 to 63 Hz, single phase
At least 70% 1 to 135 V AC/2 to 270 V AC (135 V/270 V range)
1.4 to 190 V DC/2.8 to 380 V DC (135 V/270 V range)
0.1 V AC mode: 500 VA at maximum DC mode: 400 W at maximum DC mode: 800 W at maximum AC mode: 5 A/2.5 A DC mode: 4 A/2 A
2
*
3
*
Range: 40 to 500 Hz, setting: 0.1 Hz, accuracy: ±2×10
AC mode: 1000 VA at maximum AC mode: 2000 VA at maximum
AC mode: 10 A/5 A DC mode: 8 A/4 A
2
*
3
*
-4
DC mode: 1600 W at maximum AC mode: 20 A/10 A DC mode: 16 A/8 A
0.5% or less (at 50 V to 135 V/100 V to 270V at load power factor 1) ±(0.5% of rdng + 0.3 V/0.6 V)
(Output voltage greater than 13.5 V/27 V and output frequency 45 Hz to 65 Hz/DC at 23 ± 5°C) ±(0.5% of rdng + 0.02 A/0.01 A) ±(0.5% of rdng + 0.04 A/0.02 A) ±(0.5% of rdng + 0.08 A/0.04 A) (5% to 100% of the maximum output current and output frequency 45 Hz to 65 Hz or DC at 23 ± 5°C) 214W × 124 (150)H × 350 (395)D mm
429 (450)W × 128 (150)H × 350 (400)D mm 429 (450)W × 128 (150)H × 450 (500)D mm
Approximately 6 kg Approximately 11 kg Approximately 15 kg
0 to 40°C, 20%rh to 80%rh (non-condensing)
-10°C to 60°C, 90%rh or less (non-condensing)
Conforms to EIA232D specifi cations. D-SUB9 pin connector. Baud rate: 1200, 2400, 4800, 9600, 19200 bps Data length: 8 bits, stop bit: 1 bit, no parity bit, X-Flow contorol
Conforms to IEEE STD.488.1-1978 specifi cations. SH1, AH1, T6, L4, SR1, RL1, PP0, DC1, DT1, C0, E1
Conforms to USB 2.0 specifi cations. Conforms to USBTMC-USB488 device class specifi cations. Communication speed: 12 Mbps (full speed)
Software protocol: IEEE 488.2 STD 1992 Command language: SCPI Specifi cation 1999.0
2
*
3
*
Dimensions (units: mm)
214
PCR500M
MAX 450
429
PCR1000M
MAX 25
350
MAX 395
124
MAX 150
MAX 20
MAX 30
350
MAX 15
128
MAX 30
MAX 400
MAX 150
Analog interface specifi cations (EXO4-PCR-M: optional)
Maximum allowable input voltage
Input terminal
Type Input impedance Isolation voltage Input voltage range
EXT-AC mode
1
*
Voltage amplifi cation rate (135 V/270 V range) Frequency setting range
Input voltage range
EXT-DC mode
Output voltage distortion ratio
*1
ATT is always set to on.
*2
Measurable range for voltage, current and power is DC and from 40 Hz to 500 Hz. The frequency is set based on the input waveform cycle.
*3
In the EXT-AC mode, when direct current is input. In the EXT-DC mode, when a sine wave with 0.1% or less distortion rate is input.
Input frequency range Frequency characteristics
Voltage amplifi cation rate (135 V/270 V range)
3
*
ATT off 0 V to ±1.90 Vpeak (0 to 1.35 Vrms sine wave) ATT on 0 V to ±10 V (DC) ATT off ATT off – 0.3 dB at 500 Hz with respect to 55 Hz (typical value) ATT off 100 times or 200 times ATT on 19 times or 38 times
1-877-876-2807
530 Lakeside Drive, Suite#180, Sunnyvale, CA 94085, U.S.A. Phone : 408-733-3432 Facsimile : 408-733-1814
Room, D-01,11F, Majesty Bld, No.138, Pudong Ave, Shanghai Cit Phone : 021-5887-9067 Facsimile : 021-5887-9069
Printed in Japan Issue:Sep.2011 2011091KSOHEC51
±15 V BNC 10 kΩ ± 5% (not unbalanced) ±100 Vmax 0 V to ±10 V (DC)
13.5 times or 27 times 40 Hz to 500 Hz
2
*
40 Hz to 500 Hz (sine wave) /40 Hz to 100 Hz (square wave) /DC
Main unit specifi cations + 0.5% or less
Distributor:
www.kikusuiamerica.com
All products contained in this catalogue are equipment and devices that are premised on use under the supervision
of qualifi ed personnel, and are not designed or produced for home-use or use by general consumers. design and so forth are subject to change without prior notice to improve the quality. subject to change and production may be discontinued when necessary.
www.kikusui.cn
brand names contained in this catalogue represent the respective registered trade name or trade mark. textures and so forth of photographs shown in this catalogue may differ from actual products due to a limited fi delity in printing.
certain details have unavoidably been omitted due to limitations in space. catalogue, it would be appreciated if you would inform us. price, accessories or anything that may be unclear when placing an order or concluding a purchasing agreement.
450
MAX 500
MAX 450
429
MAX 15
128
MAX 150
PCR2000M
Specifi cations,
Product names and prices are
Product names, company names and
Although every effort has been made to provide the information as accurate as possible for this catalogue,
Please contact our distributors to confi rm specifi cations,
If you fi nd any misprints or errors in this
Colors,
Loading...