 The PCD 150 is used for surge coupling onto
Coupling and decoupling elements are included in one box because of the sensitive impulse shape.
Manual coupling path switching for differential mode (transverse mode, line to line) and for common mode (longitudinal, line to earth) testing.
Default coupling and protection elements are breakdown avalanche diodes. Therefore the capacitive load to the EUT lines is low.
The PCD 150 can be used together with the impulse modules PIM 150 and the PIM 110 from the Surge Platform. The PSURGE 8000 Surge Platform provides all the programming functions required to perform IEC, ANSI and EN testing also without the need of a control computer.
With a 100 year history of innovation, service centers on three continents and a full staff development and support engineers, Haefely is the clear choice for all your transient immunity test needs.
Features
Damped oscillatory wave 100kHz and 1MHz Ring Wave 100kHz with Z=200 Ohm Up to 4 wires can be tested with a single unit Up to 8 wires can be tested with two units Signal Bandwidth up to some 10kHz Low capacitive load on the EUT lines
Benefits
International application – Specifically designed
to meet and exceed the requirements of:
- IEC/ EN 61000-4-12 Edition 1 Figure 9, 10, 13
and 14
- IEC/ EN 61000-4-18 Edition 1 Figure 7, 8, 11
and 12
Safe and Easy - All the sockets are safety banana plugs to ensure maximum safety to the user. The selected coupling path can be seen easily at the front panel.
Sturdy and Reliable - Careful component selection ensures that the PCD 150 will continue to operate under the most strenuous testing regimen.
Report Generation - The controller can automatically generate test reports without a computer.
Add WinFEAT&R control and reporting software on a host PC to collect and collate data in any format you like.
Applications
Substation equipment Static Relays Other international requirements for damped
oscillatory waves 100kHz / 1MHz and ring wave 100kHz with Z=200 Ohm
Technical Specifications
Coupling Part Decoupling Part
Impulse shapes Damped Oscillatory Wave
with 100kHz and 1MHz
Voltage on EUT
lines
max. 56VDC or 40V
Ring wave 100kHz, 200 Ohm
EUT current max. 1A per path
Impulse amplitude max. 3.3kV damped
oscillatory waves
EUT signal
bandwidth
up to some 10kHz (dependant on system impedance)
max. 4.4kV ring wave 100kHz
Residual voltage at
approx. 80V
AUX input port
Coupling elements Avalanche breakdown diodes Protection elements
at AUX input port
Avalanche breakdown diodes
- from each line to each
other line
- from each line to ground
Capacitors 5nF from each line to ground
Other coupling and protection elements on request.
Weight and Dimensions
Weight approx. 2 kg net
Dimensions 24 x 16 x 12 cm (w x h x d)
PCD 150 Art. No. 2498040 Scope of supply
WinFEAT&R Control Window
AC,RMS
Qty. 1 PCD 150 Qty. 1 HV cable Fischer to safety banana plugs Qty. 1 Cable set Qty. 5 Short circuit bridges Qty. 1 Users Manual
Options and Accessories
PSURGE 8000 Surge Platform Mainframe
Art. No. 2499000
PIM 110 Impulse module Ring Wave 100kHz
Art. No. 2499030
PIM 150 Impulse module Damped Oscillatory
Wave with both 100kHz and 1MHz
Art. No. 2499390
WinFEAT&R Control and reporting software. Runs
under windows 98, NT, ME, 2000, XP
Art. No. 2499701
Headquarters Haefely Test AG Lehenmattstrasse 353 CH-4052, Basel Switzerland
+ 41 61 373 41 11 + 41 61 373 45 99
EMC-sales@haefely.com

Haefely has a policy of continuous product improvement. Therefore we reserve the right to change design and specification without notice. PCD150_2010-04-26.doc
Locate your local sales representative at
www.haefelyEMC.com
EMCsales@hubbell-haefely.com
North American Office
Hipotronics Inc.
Haefely EMC Division
1650 Route 22
Brewster, NY 10509
++1 845 279 3644 x264
++1 845 279 2467
Loading...