A wide range of EMC test specifications including CISPR 22, FCC, ANSI C63.4 and many
others use a standard 50, 50uH and its primary variant the 50, 50uH +5 for conducted
emissions testing. CISPR 16-1-2 most precisely defines the performance requirements of
these devices.
Informative Schematic
Model Number
FCC-LISN-50-25-(X)-(XX)
FCC-LISN-50-50-(X)-(XX)
Frequency
(MHz)
.15 – 30 50uH 25A 240V / 480V DC-60Hz 1, 2, 4
.15 – 30
Network
Inductance
Maximum
Current
Voltage
Options
Power
Freq.
Number of
Lines
50uH 50A 240V / 480V DC-60Hz 1, 2, 4
Standard 50 LISN for CISPR-16
FCC-LISN-50-100-(X)-(XX) .15 – 30 50uH 100A 240V / 480V DC-60Hz 1, 2, 4
FCC-LISN-50-100-(X)-(XX) .15 – 30 50uH 200A 240V / 480V DC-60Hz 1, 2, 4
FCC-LISN-50-400-(X)-(XX)
FCC-LISN-50-50-25-(X)-(XX) .15 – 30
FCC-LISN-50-50-(X)-(XX) .15 – 30 50uH 50A 240V / 480V DC-60Hz 1, 2, 4
FCC-LISN-50-100-(X)-(XX)
FCC-LISN-50-200-(X)-(XX)
50uH 400A 240V / 480V DC-60Hz 1
.15 – 30
50uH 25A 240V / 480V DC-60Hz 1, 2, 4
50uH 100A 240V / 480V DC-60Hz 1, 2, 4
.15 – 30
50uH 200A 240V / 480V DC-60Hz 1, 2, 4
.15 – 30
For connector options, please see table 3, (xx) defines EUT power connections, (x) defines
number of lines All the models listed above meet the performance requirements for
the 50, 50uH LISN circuit defined in CISPR 16-1-2, 2006, including the common mode
impedance, phase and decoupling isolation.
An alternative LISN circuit, 50, 50uH +5, is often used by test engineers to perform conducted
emission testing defined in CISPR test specifications. This LISN originated with VDE conducted
emissions testing. It is also the LISN required for CISPR 15 testing of luminaries. It includes additional
inductors and capacitors for filtering and has an operating frequency of 9kHz – 30MHz.
Model Number
FCC-LISN-50/250-16-(X)-(XX) .009 - 30 50/250 uH 16A
FCC-LISN-50/250-25-(X)-(XX)
Frequency
.009 - 30
Informative schematic
Network
(MHz)
Inductance
50/250 uH 25A
Maximum
Current
Voltage
Options
240V
480V
240V
480V
Power
Freq.
DC-60Hz 1, 2, 4
DC-60Hz 1, 2, 4
Number of
Lines
Standard 50
LISN for CISPR-16
FCC-LISN-50/250-50-(X)-(XX) .009 - 30 50/250 uH 50A
FCC-LISN-50/250-100-(X)-(XX) .009 - 30 50/250 uH 100A
FCC-LISN-50/250-25-(X)-(XX) .009 - 30
FCC-LISN-50/250-50-(X)-(XX) .009 - 30
50/250 uH 25A
50/250 uH 50A
240V/
480V
240V
480V
240V
480V
240V
480V
DC-60Hz 1, 2, 4
DC-60Hz 1, 2, 4
DC-60Hz 1, 2, 4
DC-60Hz 1, 2, 4
For connector options, please see table 3, (xx) defines EUT power connections, (x) defines the
number of lines. All the models listed above meet the performance requirements defined
in CISPR 16-1-2, 2006 for the 50, 50uH +5 LISN circuit, including common mode impedance,
phase, and decoupling isolation