Argantix KDC Series
5–15 kW
Overview
• High Precision Power
Very high precision, very low noise, excellent dynamics
• 5 to 15 kW And Beyond Modular construction supports 5, 10 and 15 kW versions. Higher output using parallel operaton of multiple KDC units.
• Protection Modes User selectable constant voltage trip or constant current modes.
• Built-in Measurements Voltage, current and power readback capability standard.
• Transient Programming User dened output sequence programming from the front panel.
• Standard RS232C Interface and optional GPIB. Instrument drivers and software support for easy system integration.
Compact Power
The KDC Series packs up to 15 kW of DC power into a small rack mount chassis. Despite the high power density of this design, the KDC Series provides low noise, stable output.
A full set of measurements is built-in to provide instant feedback on EUT load characteristics.
The KDC Series offers all the basic DC power supply capabilities needed for a wide range of applications and provides cost effective alternative to larger and more expensive products typically used for these applications.
Easy To Use Controls
Simple menu driven operation and familiar rotary controls for setting voltage and current ensures that the KDC Series Power Supplies are easy to operate. All front panel controls including the rotary knobs are digitally encoded for long lasting, trouble free operation. The voltage and current control knobs can be used to quickly slew output parameters.
The intuitive front panel controls allow for easy operation of the supply by both novice and experienced users alike.
Applications
With excellent output regulation and accuracy, the KDC Series DC Power Supplies support a wide variety of DC power applications. Examples include communications, semiconductors, automotive, information technology and industrial. The standard RS232C serial interface supports remote control of all power supply functions and measurements and allows for easy integration into ATE systems. Use of standard SCPI command language syntax and instrument drivers for popular programming environments further ease system integration. An optional GPIB/analog interface is available as well.
KDC Series - Controller Capabilities
All KDC Series Power Supplies use an advanced DSP based controller with a menu driven user interface. This controller provides capabilities not typically found in most DC supplies. Output Sequencing: Time driven output changes can be programmed, stored and executed under program control. Events include steps, sweeps, drops and surges of voltage and/or current. This allows a variety of power conditions and DC tests to be set up and executed from the front panel. Multiple sequences can be stored in non­volatile memory for quick recall. Parallel Mode: Several KDC units can be combined to provide high output current capability using a master / auxiliary combination. Output Impedance: A programmable output impedance function allows simulation of DC source impedance as a function of load conditions. Remote Control: The included KDCGUI program provides easy access to these and other KDC controller capabilies using a Windows PC with the standard RS232C or the optional IEEE-488/GPIB interface.
30–600 V
8–500 A
208 400 480
AMETEK Programmable Power
9250 Brown Deer Road San Diego, CA 92121-2267 USA
858.458.0223
sales@ProgrammablePower.com 63
KDC Series : Specications
Output
Power: Maximum 5, 10 or 15 KW Voltage: Line Regulation: < 0.1% of Range Load Regulation: < 0.1% of Range Accuracy: ± 0.05% Setting + 0.1% Range Transient Response: Voltage will recover to within 2% of voltage range within 2 msec for a 30 % load step. Stability: ± 0.05% of max. rating per 8 hours after 30 mins warmup at xed line, load and temperature.
Current Line Regulation: < 0.1% of Range Load Regulation: < 0.1% of Range Accuracy: ± 0.05% Setting + 0.1% Range Stability: ± 0.05% of setting after 8 hour warmup at xed line, load and temperature.
Input
Voltage: 208 - 10 % to 230 + 10% VAC 400 ± 10 % VAC 480 ± 10 % VAC All inputs are L-L, 3 phase, 3- wire plus safety ground. Input rating must be specied at time or order. Current RMS: Typical RMS current per phase at low line input voltage. Power Factor: > 0.65 Efciency: > 85 % at full load.
Power Level
Vlow 5 kW 10 kW 15 kW
187 V 27 A 54 A 81 A
360 V 15 A 30 A 45 A
432 V 12 A 24 A 36 A
Measurements
Voltage
Accuracy: 0.05% + 0.1% Full Scale Resolution: 0.025% Full Scale
Current Accuracy: 0.1% + 0.2% Full Scale Resolution: 0.025% Full Scale
Power Accuracy: 0.2% + 0.3% Full Scale Resolution: 0.05% Full Scale
Protection Over temperature, short circuit, over current protection, open sense.
Controls and Indicator Controls: Dual digitally encoded rotary knobs, Function keys, Output on/off, Power on/off
Indicators Display: Alphanumeric LCD, dual line. LED’s for: Output on/off, CC mode, CV mode, CP mode and Remote.
Remote Control A standard RS232C is included with all KDC Series DC Power Supplies. An optional GPIB/IEEE­488 with analog RPV (0-10 VDC) input is available as well.
RS232C / RS485 - Standard 9 pin D-shell connector, 115200 baud max., SCPI syntax.
-IF option: IEEE-488 Interface IEEE-488 (GPIB) talker listener. Subset: AH1, C0, DC1, DT1, L3, PP0, RL2, SH1, SR1, T6 IEEE-488.2 SCPI syntax
Analog interface: Voltage control: 0-10 VDC, 0-5 VDC or R for 0-100% range Current control: 0-10 VDC, 0-5 VDC or R for 0-100% range I/O Connectors: Analog I/O, 15 Pin D-sub, isolated Auxiliary I/IO, 9 Pin D-sub nonisolated. Functions: Remote Output On/Off Trigger Input Function strobe out. Volt Monitor out Current Monitor out
Environmental
Temperature Coefcient
Voltage set point: 0.02%/°C of V Range Current set point: 0.03%/°C of I Range
Ambient Temperature Operating: 0° to 40° C / 32° to 104° F Storage: -40° to 75° C / -40° to 167° F
Humidity Operating: 0 to 80% RH, non condensing
Cooling Forced air, side and top intake, rear exhaust.
© 2009 AMETEK Programmable Power All rights reserved. AMETEK Programmable Power is the trademark of AMETEK Inc., registered in the U.S. and other countries. Elgar, Sorensen, California Instruments, and Power Ten are trademarks of AMETEK Inc., registered in the U.S.
www.ProgrammablePower.com64
KDC Series : Specications
5–15 kW
Mechanical
Dimensions
Height: 5.25” / 133.35 mm Width: 19” / 482.6 mm Depth: 22.19” / 563.3 mm excl. bus bars and cover 24.74” / 628.4 mm incl. bus bars and cover Weight 15 KW 10 KW 5KW Net: 84 lbs. 70 lbs. 56 lbs.
38.1 Kg 32 Kg 25.4 Kg
Shipping (approx.): 110 lbs. 96 lbs. 82 lbs. 50 Kg 44 Kg 37.2 Kg
Rack Mounting Unit must be supported by shelf or brackets when mounted in 19” cabinet. No provisions for rack slides are made on instrument.
Ordering Information
Model
All KDC Series model numbers specify voltage and current range.
KDC VVV-CCC-LLL-XX. VVV = Voltage CCC = Current LLL = Input Line Voltage XX = Options
Refer to table shown for model numbers and congurations.
Supplied with User manual and programming manual on CD ROM. Windows GUI software on CD ROM. RS232C serial cable.
Options
-IF GPIB / IEEE-488 interface and analog remote voltage programming option.
Ordering Examples: Model Description KDC 50-200-208 Output voltage 50 Vdc, maximum current is 200 Adc, line input is 208 V line to line, three phase. Includes standard RS232C remote interface.
KDC 80-187-400-IF Output voltage 80 Vdc, maximum current is 187 Adc, line input is 400 V line to line, three phase. Includes optional IEEE/RS232 and analog interfaces.
XDS Series Products For applications requiring only basic controller functions but similar power levels and voltage ranges as the KDC Series, refer to the Argantix XDS Series.
KDC Series - Models¹
Model
KDC 30-167 5 30 166.7 15 mV
KDC 30-333 10 30 333.3 15 mV
KDC 30-500 15 30 500 15 mV
KDC 50-100 5 50 100 15 mV
KDC 50-200 10 50 200 15 mV
KDC 50-300 15 50 300 15 mV
KDC 80-62 5 80 62.5 25 mV
KDC 80-125 10 80 125 25 mV
KDC 80-187 15 80 187.5 25 mV
KDC 100-50 5 100 50 25 mV
KDC 100-100 10 100 100 25 mV
KDC 100-150 15 100 150 25 mV
KDC 150-33 5 150 33.3 25 mV
KDC 150-66 10 150 66.7 25 mV
KDC 150-100 15 150 100 25 mV
KDC 300-17 5 300 16.7 100 mV
KDC 300-33 10 300 33.3 100 mV
KDC 300-50 15 300 50 100 mV
KDC 600-8 5 600 8.3 250 mV
KDC 600-17 10 600 16.7 250 mV
KDC 600-25 15 600 25 250 mV
Note 1: Contact factory for availability of models with output voltage ranges not listed here.
KW Volts Amps
Output
RMS Noise & Ripple (Typ.)
858.458.0223
sales@ProgrammablePower.com 65
Notes
www.ProgrammablePower.com66