Very high precision, very low noise,
excellent dynamics
• 5 to 15 kW And Beyond
Modular construction supports 5, 10 and 15 kW
versions. Higher output using parallel operaton of
multiple KDC units.
• Protection Modes
User selectable constant voltage trip or constant
current modes.
• Built-in Measurements
Voltage, current and power readback capability
standard.
• Transient Programming
User dened output sequence programming from
the front panel.
• Standard RS232C Interface and optional GPIB.
Instrument drivers and software support for easy
system integration.
Compact Power
The KDC Series packs up to 15 kW of DC power
into a small rack mount chassis. Despite the high
power density of this design, the KDC Series
provides low noise, stable output.
A full set of measurements is built-in to provide
instant feedback on EUT load characteristics.
The KDC Series offers all the basic DC power
supply capabilities needed for a wide range of
applications and provides cost effective alternative
to larger and more expensive products typically
used for these applications.
Easy To Use Controls
Simple menu driven operation and familiar rotary
controls for setting voltage and current ensures
that the KDC Series Power Supplies are easy to
operate. All front panel controls including the
rotary knobs are digitally encoded for long lasting,
trouble free operation. The voltage and current
control knobs can be used to quickly slew output
parameters.
The intuitive front panel controls allow for easy
operation of the supply by both novice and
experienced users alike.
Applications
With excellent output regulation and accuracy,
the KDC Series DC Power Supplies support a
wide variety of DC power applications. Examples
include communications, semiconductors,
automotive, information technology and
industrial. The standard RS232C serial interface
supports remote control of all power supply
functions and measurements and allows for easy
integration into ATE systems. Use of standard SCPI
command language syntax and instrument drivers
for popular programming environments further
ease system integration. An optional GPIB/analog
interface is available as well.
KDC Series - Controller Capabilities
All KDC Series Power Supplies use an advanced
DSP based controller with a menu driven user
interface. This controller provides capabilities
not typically found in most DC supplies. Output
Sequencing: Time driven output changes can
be programmed, stored and executed under
program control. Events include steps, sweeps,
drops and surges of voltage and/or current. This
allows a variety of power conditions and DC
tests to be set up and executed from the front
panel. Multiple sequences can be stored in nonvolatile memory for quick recall. Parallel Mode:
Several KDC units can be combined to provide
high output current capability using a master
/ auxiliary combination. Output Impedance: A
programmable output impedance function allows
simulation of DC source impedance as a function
of load conditions. Remote Control: The included
KDCGUI program provides easy access to these
and other KDC controller capabilies using a
Windows PC with the standard RS232C or the
optional IEEE-488/GPIB interface.
30–600 V
8–500 A
208400480
AMETEK
Programmable Power
9250 Brown Deer Road
San Diego, CA 92121-2267
USA
858.458.0223
sales@ProgrammablePower.com63
KDC Series : Specications
Output
Power: Maximum 5, 10 or 15 KW
Voltage: Line Regulation: < 0.1% of Range
Load Regulation: < 0.1% of Range
Accuracy: ± 0.05% Setting + 0.1% Range
Transient Response: Voltage will recover to within
2% of voltage range within 2 msec for
a 30 % load step.
Stability: ± 0.05% of max. rating per 8 hours
after 30 mins warmup at xed line,
load and temperature.
Current
Line Regulation: < 0.1% of Range
Load Regulation: < 0.1% of Range
Accuracy: ± 0.05% Setting + 0.1% Range
Stability: ± 0.05% of setting after 8 hour
warmup at xed line, load and
temperature.
Input
Voltage: 208 - 10 % to 230 + 10% VAC
400 ± 10 % VAC
480 ± 10 % VAC
All inputs are L-L, 3 phase, 3- wire plus
safety ground. Input rating must be specied at time or order.
Current RMS: Typical RMS current per phase at
low line input voltage.
Power Factor: > 0.65
Efciency: > 85 % at full load.
Power Level
Vlow5 kW10 kW15 kW
187 V27 A54 A81 A
360 V15 A30 A45 A
432 V12 A24 A36 A
Measurements
Voltage
Accuracy: 0.05% + 0.1% Full Scale
Resolution: 0.025% Full Scale
Current
Accuracy: 0.1% + 0.2% Full Scale
Resolution: 0.025% Full Scale
Power
Accuracy: 0.2% + 0.3% Full Scale
Resolution: 0.05% Full Scale
Protection
Over temperature, short circuit, over current
protection, open sense.
Controls and Indicator
Controls: Dual digitally encoded rotary knobs,
Function keys, Output on/off, Power
on/off
Indicators
Display: Alphanumeric LCD, dual line.
LED’s for: Output on/off, CC mode, CV mode,
CP mode and Remote.
Remote Control
A standard RS232C is included with all KDC
Series DC Power Supplies. An optional GPIB/IEEE488 with analog RPV (0-10 VDC) input is available
as well.
Analog interface:
Voltage control: 0-10 VDC, 0-5 VDC or R for
0-100% range
Current control: 0-10 VDC, 0-5 VDC or R for
0-100% range
I/O Connectors: Analog I/O, 15 Pin D-sub, isolated
Auxiliary I/IO, 9 Pin D-sub nonisolated.
Functions:
Remote Output On/Off
Trigger Input
Function strobe out.
Volt Monitor out
Current Monitor out
Environmental
Temperature Coefcient
Voltage set point: 0.02%/°C of V Range
Current set point: 0.03%/°C of I Range
Ambient Temperature
Operating: 0° to 40° C / 32° to 104° F
Storage: -40° to 75° C / -40° to 167° F
Humidity
Operating: 0 to 80% RH, non condensing
Cooling
Forced air, side and top intake, rear exhaust.
Height: 5.25” / 133.35 mm
Width: 19” / 482.6 mm
Depth: 22.19” / 563.3 mm excl. bus bars
and cover 24.74” / 628.4 mm incl. bus
bars and cover
Weight 15 KW 10 KW 5KW
Net: 84 lbs. 70 lbs. 56 lbs.
38.1 Kg 32 Kg 25.4 Kg
Shipping (approx.): 110 lbs. 96 lbs. 82 lbs.
50 Kg 44 Kg 37.2 Kg
Rack Mounting
Unit must be supported by shelf or brackets when
mounted in 19” cabinet. No provisions for rack
slides are made on instrument.
Ordering Information
Model
All KDC Series model numbers specify voltage
and current range.
KDC VVV-CCC-LLL-XX.
VVV = Voltage
CCC = Current
LLL = Input Line Voltage
XX = Options
Refer to table shown for model numbers and
congurations.
Supplied with
User manual and programming manual
on CD ROM.
Windows GUI software on CD ROM.
RS232C serial cable.
Options
-IF GPIB / IEEE-488 interface and analog remote
voltage programming option.
Ordering Examples:
Model Description
KDC 50-200-208 Output voltage 50 Vdc, maximum current is
200 Adc, line input is 208
V line to line, three phase.
Includes standard RS232C
remote interface.
KDC 80-187-400-IF Output voltage 80 Vdc,
maximum current is 187
Adc, line input is 400 V line
to line, three phase. Includes
optional IEEE/RS232 and
analog interfaces.
XDS Series Products
For applications requiring only basic controller
functions but similar power levels and voltage
ranges as the KDC Series, refer to the Argantix
XDS Series.
KDC Series - Models¹
Model
KDC 30-167530166.715 mV
KDC 30-3331030333.315 mV
KDC 30-500153050015 mV
KDC 50-10055010015 mV
KDC 50-200105020015 mV
KDC 50-300155030015 mV
KDC 80-6258062.525 mV
KDC 80-125108012525 mV
KDC 80-1871580187.525 mV
KDC 100-5051005025 mV
KDC 100-1001010010025 mV
KDC 100-1501510015025 mV
KDC 150-33515033.325 mV
KDC 150-661015066.725 mV
KDC 150-1001515010025 mV
KDC 300-17530016.7100 mV
KDC 300-331030033.3100 mV
KDC 300-501530050100 mV
KDC 600-856008.3250 mV
KDC 600-171060016.7250 mV
KDC 600-251560025250 mV
Note 1: Contact factory for availability of models with output voltage ranges not listed here.
KWVoltsAmps
Output
RMS Noise & Ripple (Typ.)
858.458.0223
sales@ProgrammablePower.com65
Notes
www.ProgrammablePower.com66
Loading...