Atec iX User Manual

California Instruments i/iX Series II
3000–15000 VA
General purpose AC power sources
• Combination AC and DC Power Source and Power Analyzer
• 3000 VA - 15000 VA of Output Power
• Arbitrary Waveform Generation
• Built-in Digital Power Analyzer
• EN61000-3-2 and EN61000-3-3
• Powerful Programing Software
• Constant Power Mode
Intergrated System The iX Series II represents a new generation of AC and DC power source that addresses increasing demands on test equipment to perform more functions at a lower cost. By combining a exible AC/DC power source with a high performance power analyzer, the iX Series II systems are capable of handling complex applications that have traditionally required multiple instruments.
The sleek integrated approach of the iX Series II avoids the cable clutter that is commonly found in AC test systems. The i/iX Series II is rackmountable with a 4U chassis design. All connections are made internally and the need for external digital multimeters, power harmonics analyzer and current shunts or clamps is completely eliminated.
Using a state of the art digital signal processor in conjunction with precision high resolution A/D converters, the iX Series II provides more accuracy and resolution than can be found in some dedicated harmonic power analyzers. Since many components in the iX Series II are shared between the AC/DC source and the power analyzer, the total cost of the integrated system is less than the typical cost of a multiple unit system.
For less demanding applications, the i Series II provides similar output and transient capabilities as the iX Series II, as well as basic measurements.
Easy To Use Controls Both the iX Series II and i Series II are microprocessor controlled and can be operated from an easy to use front panel keypad. Functions are grouped logically and are directly accessible from the keypad. This eliminates the need to search through various levels of menus and/or soft keys. A large analog control knob can be used to quickly slew output parameters. This
knob is controlled by a dynamic rate change algorithm that combines the benets of precise control over small parameter changes with quick sweeps through the entire range.
Applications With precise output regulation and accuracy, the iX Series II AC and DC sources address many application areas for AC and DC power testing. The iX also provides a high load current capability, multi or single phase output modes, and built-in power analyzer measurements. Additional features including line distortion simulation (LDS), arbitrary waveform generation, and programmable output impedance address requirements for product quality and regulatory compliance testing.
Product Evaluation and Test Increasingly, manufacturers of electronic equipment and appliances are required to fully evaluate and test their products over a wide range of input line conditions. The built-in output transient generation and readback measurement capability offers the convenience of an easy to use and integrated test system.
Avionics With an output frequency range to 1000 Hz, up to 150 VRMS, the iX Series II is well suited for aerospace applications. Precise frequency control and accurate load regulation are key requirements in these applications. The standard IEEE-488 control interface and SCPI command language provide for easy integration into existing ATE systems. Since the iX Series II can eliminate the need for additional pieces of test equipment and only occupies 7 inches of rack space (4U), it signicantly saves cost and space. Options are available for popular avionics test routines such as: DO-160, ABD- 0100, MIL-STD-704A-F, Boeing 7E73B-0147, and Airbus test routines.
150–300 V
0–120 A
208 230 400
208 230
858.458.0223
sales@ProgrammablePower.com 169
i/iX Series II
Regulatory Testing
As governments are moving to enforce product quality standards, regulatory compliance testing is becoming a requirement for a growing number of manufacturers. The iX Series II is designed to meet AC source requirements for use in Euronorm EN 61000 compliance testing. For icker testing, the programmable output impedance capability of the 3001iX, 5001iX and 15003iX can be used to create the required IEC 725 reference impedance. Run IEC61000­4-11, IEC61000-4-14 and IEC61000-4-28 test programs.
Multi-Box Congurations For high power applications, two or three 5001i/ iX chassis can be combined to provide 10 to 15 kVA of single or three phase power. A 9003iX, 15003iX or 15003i three phase conguration can be ordered with the MODE-iX option. This option allows automatic switching between single or three phase output mode. In single phase mode, all current is available on phase A.
High Crest Factor With a crest factor of up to 5:1, the i/iX Series II AC source can drive difcult nonlinear loads with ease. Since many modern products use switching power supplies, they have a tendency to pull high repetitive peak currents. The 5001iX can deliver up to 110 Amps of repetitive peak current to handle such loads.
Remote Control Standard IEEE-488 and RS232C remote control interfaces allow programming of all instrument functions from an external computer. The popular SCPI command protocol is used for programming. Drivers for several popular instrumentation programming environments are available to facilitate systems integration of the i/iX Series II. Instrument drivers for popular programming environments such as National Instruments LabView™ are available to speed up system intergration.`
Application Software Windows® application software is included with the iX and i Series II¹ . This software provides easy access to the power source’s capabilities without the need to develop any custom code. The following functions are available through this GUI program:
• Steady state output control (all parameters)
• Create, run, save, reload and print
transient programs
• Generate and save harmonic waveforms [iX only]
• Generate and save arbitrary waveforms [iX only]
• Download data from a digital storage
oscilloscope [iX only]
• Measure and log standard measurements
• Capture and display output voltage and
current waveforms [iX only]
• Measure, display, print and log harmonic voltage and current measurements [iX only]
• Display IEEE-488 or RS232C bus trafc to and from the AC Source to help you develop your own test programs..
1. Requires PC running WindowsXP™ or Windows 2000™
www.ProgrammablePower.com170
i/iX Series II
3000–15000 VA
Harmonic Waveform Generation Using the latest DSP technology, the iX Series II controller is capable of generating harmonic waveforms to test for harmonics susceptibility of a unit under test. Included is a Graphical User Interface program that can be used to dene harmonic waveforms by specifying amplitude and phase for up to 50 harmonics. The waveform data points are generated and downloaded by the GUI to the AC source through either the USB, IEEE-488, RS232C bus or LAN and remain in nonvolatile memory. Up to 200 waveforms can be stored and given a user dened name for easy recall.
The three phase conguration iX Series II offers independent waveform generation on each phase allowing three phase anomalies to be programmed. It also allows simulation of unbalanced harmonic line conditions.
Harmonic waveform, Fund., 3rd, 5th, 7th, 9th,11th and 13th.
Two hundred user dened waveforms.
Arbitrary Waveform Generation [iX Series II only]
Using the provided GUI program or custom software, the user also has the ability to dene arbitrary AC waveforms. The arbitrary waveform method of data entry provides an alternative method of specifying AC anomalies by providing specic waveform data points. The GUI program includes a catalog of custom waveforms. It also allows real-world waveforms captured on a digital oscilloscope to be downloaded to one of the many AC source’s waveform memories.
Arbitrary waveform capability is a exible way of simulating the effect of real-world AC power line conditions in both engineering and production environments.
iX and i Series II - AC and DC Transient Generation
The iX and i Series II controllers have a powerful AC and DC transient generation system that allows complex sequences of voltage, frequency and waveshapes to be generated. This further enhances the i/iX’s capability to simulate AC line conditions or DC disturbances. When combined with the multi phase arbitrary waveform capabilities, the AC and DC output possibilities are truly exceptional. In three phase i/iX system congurations, transient generation is controlled independently yet time synchronized on all three phases. Accurate phase angle control and synchronized transient list execution provide unparalleled accuracy in positioning AC output events.
Transient programming is easily accomplished from the front panel where clearly laid out menu’s guide the user through the transient denition process. The front panel provides a convenient listing of the programmed transient sequence and allows for transient execution, Start, Stop, Abort and Resume operations.
User dened transient sequences can be saved to nonvolatile memory for instant recall and execution at a later time. The included Graphical User Interface program supports transient denitions using a spreadsheet-like data entry grid. A library of frequently used transient programs can be created on disk using this GUI program.
Transient List Data Entry from the front panel
Two hundred user dened waveforms.
858.458.0223
Transient List Data Entry in GUI program.
sales@ProgrammablePower.com 171
i/iX Series II
Measurement and Analysis
The i/iX Series II is much more than a programmable AC and DC power source. It also incorporates an advanced digital signal processor based data acquisition system that continuously monitors all AC source and load parameters. This data acquisition system forms the basis for all measurement and analysis functions. These functions are accessible from the front panel and the remote control interface.
Measurement data for single phase (iX Display).
Measurement data for all three phases (iX Display).
Harmonic Analysis [iX Series II only] The iX Series II provides detailed amplitude and phase information on up to 50 harmonics of the fundamental voltage and current for either one or three phases. Harmonic content can be displayed in both tabular and graphical formats on the front panel LCD for immediate feedback to the operator. Alternatively, the included GUI program can be used to display, print and save harmonic measurement data. Total harmonic distortion of both voltage and current is calculated from the harmonic data.
Waveform Acquisition [iX Series II only] The measurement system is based on real-time digitization of the voltage and current waveforms using a 4K deep sample buffer. This time domain information provides detailed information on both voltage and current waveshapes. Waveform acquisitions can be triggered at a specic phase angle or from a transient program to allow precise positioning of the captured waveform with respect to the AC source output.
The front panel LCD displays captured waveforms with cursor readouts. The included GUI program also allows acquired waveform data to be displayed, printed and saved to disk.
Acquired Current waveform (iX Display).
Acquired Voltage waveform (iX Display).
Absolute amplitude bar graph display of current harmonics with cursor positioned at the fundamental (iX Display).
Voltage harmonic measurement table display in absolute values (iX Display).
www.ProgrammablePower.com172
Acquired three phase voltage waveforms display on PC.
i/iX Series II : Product Specications
3000–15000 VA
Operating Modes
iX Series II AC, DC or AC+DC
i Series II AC or DC
AC Mode Output
Frequency Range: 16.00-1000 Hz (Note: Voltage on 300 V range derates from 300 Vrms max at 500 Hz to 150 Vrms max at 1000 Hz;
Total Power 3001i/iX: 3000 VA, 5001i/iX: 5000 VA, 9003i/iX: 3000 VA per phase, with mode iX: 9000 VA 1ø, 10001i/iX: 10000 VA, 15001i/iX:
Load Power Factor 0 to unity at full output VA
See V-F rating chart. below)
15000 VA, 15003i/iX: 5000 VA/ø 3ø, with mode iX: 15000 VA 1ø
AC Mode Voltage
Voltage Ranges
Output Noise (20 kHz to 1 MHz) < 250 mVrms typ., < 500 mVrms max
Harmonic Distortion (Linear) < 1% from 16 - 66 Hz, < 2% at 400 Hz, < 3% at 800 Hz (Full resistive load)
DC Offset < 20 mV
External Amplitude Modulation Depth: 0 - 10 %, Frequency: DC - 2 KHz
Isolation Voltage 300 Vrms output to chassis
Voltage slew rate 200 µs for 10% to 90% of full scale change into resistive load, 0.5V / µSec
Range V Low V High
AC 0-150 V 0-300 V
AC+DC 0-150 V 0-300 V Line Regulation: < 0.1% for 10% line change
Load Regulation (with ALC on):
Load Regulation (with ALC off):
< 0.2%
< 0.5% DC to 100 Hz, < 0.6% 100 Hz to 500 Hz in high voltage range, < 2.2% 100 Hz to 500 Hz in low voltage range, < 3% 500 Hz to 1000 Hz
AC Mode Current
Steady State AC Current
Peak Repetitive AC Current
Programming Accuracy Voltage (rms): ± 0.2 of range, 16 to 1000 Hz, Frequency: ± 0.01 % of programmed value, Current Limit: ± 0.5 % of programmed value,
Programming Resolution Voltage (rms): 100 mV, Frequency: 0.01 Hz from 16 - 81.91 Hz, 0.1 Hz from 82.0 - 819.1 Hz, 1 Hz from 820-1000 Hz,
Output Relay Push-button controlled or bus controlled output relay
Output Impedance (iX Only) Programmable Z on 3001iX, 5001iX, 9003iX and 15003iX (3ø mode only) for 50 Hz fundamental
Resistive Range: 17 - 1000 mOhm,resolution: 4 mOhm accuracy, 2 % FS
Inductive Range: 230 - 1000 µH, resolution: 4 µH, accuracy: 2 % FS
Model 3001i/iX 5001i/iX
300 V range 11.1 18.5
150 V range 22.2 37.0
Note: Constant power mode provides increased current at reduced voltage (See chart below)
Model 3001i/iX 5001i/iX 9003i/iX 3ø 10001i/iX 15001i/iX 15003i/iX 3ø
High range 96.0 96.0
Low range 110.0 110.0
Phase: < 1.5° with balanced load at 50/60 Hz
Current Limit: 0.1 A, Phase, 0.1°
9003i/iX
11.1 /ø
22.2 /ø
96.0 /
ø
110.0 /ø
10001i/iX 15001i/iX
37.0 55.5
74.0 111.0
192.0 288.0
220.0 330.0
15003i/iX
18.5 /ø
37.0 /ø
96.0 /ø
110.0 /ø
DC Mode Output
Power (Max at full scale of DC Voltage Range):
Voltage Ranges Range: Low: 200 Vdc, High: 400 Vdc
Line Regulation < 0.1% FS or 10% line change
Output Noise < 250 mV rms typ., < 500 mV rms max., (20 kHz to 1 MHz)
Max DC Current (Maximum current at 65% of V Range)
Current Limit Programmable from 0 A to maximum current for selected range
3001i/iX: 2100 W, 5001i/iX: 3500 W, 9003i/iX: 2100 W/ø 3ø, 6300 W 1ø, 10001i/iX: 7000 W, 15001i/iX: 10500 W, 15003i/iX: 3500 W/ø 3ø
Model 3001i/iX 5001i/iX
400V range 7.8 13 7.8 26 39 13
200V range 15.6 26 15.6 52 78 26
Note: Constant power mode provides increased current at reduced voltage (See chart below)
9003i/iX
10001i/iX 15001i/iX
15003i/iX
AC+DC Mode Output
Output Power (iX only) Full AC Power if DC component is less than 20% of full scale voltage, Full DC power if DC component is above 20%
858.458.0223
sales@ProgrammablePower.com 173
i/iX Series : Product Specications
Measurements
Output Parameter i Series iX Series
Current Limit Range Programmable 0 to 100% of range for all ranges Programmable 0 to 100% of range for all ranges
Current Limit Resolution 0.1 Arms 0.1 Arms
Current Limit Accuracy ± 0.5 A ± 0.5 A
Frequency Range 16.00 - 81.91 Hz (0.01 Hz resolution)
Frequency Accuracy ± 0.01% of programmed value ± 0.01% of programmed value
DC Offset Voltage Less than 20 mV with linear load. Less than 20 mV with linear load.
Output Impedance Range n/a Rmin to 1000 mΩ
Output Impedance Resolution n/a 4 mΩ
Output Impedance Accuracy n/a ± 2% F.S. at 796 μH and 400 mΩ
Output Noise (20 kHz to 1 MHz) <250 mV rms (typ),
1 Note: AC voltage in 300V range derates from 300 Vrms max. at 500 Hz to 150 Vrms max. at 1000 Hz.
81.0 – 819.1 Hz (0.1 Hz resolution) 820 – 1000 Hz (1 Hz resolution)¹
<500 mV rms (max)
Measurements : Peak AC Current
Output Parameter i Series iX Series
3001i/iX 5001i/iX
10001i/iX 220 A for 150 V range,
15001i/iX 330 A for 150 V range,
Crest Factor Up to 5:1 Up to 5:1
110 A for 150 V range,
92 A for 300 V range
184 A for 300 V range
276 A for 300 V range
16.00 - 81.91 Hz (0.01 Hz resolution)
81.0 – 819.1 Hz (0.1 Hz resolution) 820 – 1000 Hz (1 Hz resolution)¹
Lmin to 1000 μH
4 μH
<250 mV rms (typ),
<500 mV rms (max)
110 A for 150V range,
92 A for 300 V range,
220 A for 150 V range, 184 A for 300 V range
330 A for 150 V range, 276 A for 300 V range
AC Measurements
Parameter Range Accuracy (±) Resolution
Frequency 16.00 - 1000 Hz 2 counts 0.01: 16 to 81.91 Hz
RMS Voltage 0 - 300 Volts 0.25V + 0.1%, <100 Hz
0.25V + 0.2%, 100-1000 Hz
RMS Current 0 - 40 Amps 0.25A + 0.1%, <100 Hz
0.25A + 0.2%, 100-1000 Hz
Peak Current 0 - 119 Amps 0.5A + 0.2%, <100 Hz
0.5A + 0.5%, 100-1000 Hz
VA Power 0 – 6000 VA 10 VA + 0.1%, <100 Hz
20 VA + 0.2%, 100-1000 Hz
Real Power 0 – 6000 W 10 W + 0.1%, <100 Hz
20 W + 0.2%, 100-1000 Hz
Power Factor (>0.2kVA) 0 - 1.00 0.01
Accuracy specications apply above 100 counts. Current and Power Accuracy specications are times two for 10001iX and times three for 15001iX. For 10001iX and 15001iX, resolution decreases by factor of 10, ranges for current and power increases by factor of three. Measurement bandwidth is limited to 16 Khz.
0.1: 82.0 to 819.0 Hz 1: 820 to 1000 Hz
0.01 Volt
0.001 Amp
0.01 Amp
1 VA
1 W
DC Measurements
Parameter Range Accuracy (±) Resolution
Voltage 0 – 400 Volts 0.4 Volts 0.01 Volt
Current 0 – 40 Amps 0.1 Amps 0.001 Amp
Power 0 – 6000 W 20 W 1 W
Accuracy specications apply above 100 counts. Current and Power Accuracy specications are times two for 10001iX and times three for 15001iX. For 10001iX and 15001iX, resolution decreases by factor of 10, ranges for current and power increases by factor of three.
www.ProgrammablePower.com174
i/iX Series : Product Specications
3000–15000 VA
Harmonic Measurements (iX series)
Parameter Range Accuracy (±) Resolution
Frequency fundamental 16.00 - 1000 Hz 2 counts 0.01 Hz to 1 Hz
Frequency harmonics 32.00 Hz - 16 kHz 2° typ. 0.5°
Voltage Fundamental 0.25V 0.01V
Harmonic 2 - 50 0.25V + 0.1% + 0.1%/kHz 0.01V
Current Fundamental 0.05A 0.01A
Harmonic 2 - 50 0.05A + 0.1% + 0.1%/kHz 0.01A
Accuracy specications are times three for three phase mode. Harmonics frequency range in three-phase mode is 32 Hz - 16 kHz. Resolution decreases by factor of 10 for 10001iX and 15001iX.
Remote Control
IEEE-488 Interface optional / USB standard IEEE-488 (GPIB) talker listener. Subset: AH1, C0, DC1, DT1, L3, PP0, RL2, SH1, SR1, T6, IEEE-488.2 SCPI Syntax (GPIB standard on iX)
RS232C Interface
(LAN Optional)
9 pin D-shell connector, Handshake: CTS, RTS, Data bits: 7,8, Stop bits: 1, 2, Baud rate: 9600, 19200, 38400, 57600, 115200, IEEE-488.2 SCPI Syntax (Supplied with RS232C cable). (RS232C Standard on iX - LAN Optional)
AC Input
Voltage 3001 and 9003: 208-240 ± 10% Vac, (L-N, 1ø), All other models: Standard: 208-240 ± 10% Vac, (L-L, 3ø), Option -400: 400-480 ± 10%
Input Line Current (per phase):
Vac, (L-L, 3ø) (Input range must be specied when ordering).
Model 3001i/iX 5001i/iX 9003i/iX 10001i/iX 15001i/iX 15003i/iX
187-264V 25 A 23 A 75 A 46 A 69 A 69 A
360-528V N/A 12 A N/A 24 A 36 A 36 A
Inrush Current per chassis < 100 Apk for 100 µs at 208-240 V, < 50 Apk for 100 µs at 400-480 V
Line Frequency 50-60 Hz ± 10 %
Efciency 75% typical
Power Factor 0.6 typical
Regulatory IEC61010, EN50081-2, EN50082-2, CE EMC and Safety Mark requirements
RFI Suppression CISPR 11, Group1 , Class A
Rear Panel Connectors AC Input & Output terminal block with cover, IEEE-488 (GPIB) connector (rear panel), 9 pin D-Shell RS232C connector*, Remote voltage
sense terminal block, System Interface Connector, *RS232 DB9 to DB9 cable supplied
Mechanical
Dimensions Height: 7” (178 mm), Width: 19” (483 mm), Depth: 24” (610 mm) (depth includes rear panel connectors)
Weight per Chassis: Net: 61 lbs / 28 Kg, Shipping: 115 lbs / 52 Kg
Vibration and Shock Designed to meet NSTA project 1A transportation levels
Air Intake/Exhaust Forced air cooling, side air intake, rear exhaust.
Operating Humidity 0 to 95 % RAH, non condensing.
Temperature Operating: 0 to 40° C, Storage: -20 to +85° C
Constant Power AC Mode - Available Max. AC Current V-F Rating Chart - 300V Range
Note: Specications are subject to change without notice. Specications are warranted over an ambient temperature range of 25°± 5° C. Unless otherwise noted, specications are per phase for a sinewave with a resistive load and apply after a 30 minute warm-up period. For three phase congurations, all specications are for L-N. Phase angle specications are valid under balanced load conditions only.
858.458.0223
sales@ProgrammablePower.com 175
i/iX Series : Product Specications
Standard controller versions
Model Output Power AC Phase Output Max. current per phase Input Voltage²
Low V range High V range
AC DC AC DC
3001i/iX 3 kVA 1 22 15.6 11 7.8 208-240V
5001i/iX 5 kVA 1 37 26 18.5 13 208-240V
5001i/iX-400 5 kVA 1 37 26 18.5 13 400-480V
9003iX1 9 kVA 3 22 15.6 11 7.8 208-240V
10001i/iX¹ 10 kVA 1 74 52 37 26 208-240V
10001i/iX-400¹ 10 kVA 1 74 52 37 26 400-480V
3
10002i/iX
10002i/iX-400
15001i/iX
15001i/iX-400
15003i/iX
15003i/iX-400
3
1
1
1
1
Note (1): Supplied with System Interface cable(s). Controller in master unit only. Note (2): All input voltage specications are for Line to Line three phase except 3001iX and 9003iX which require single phase input only. Note (3): For 10002iX split phase system specications, refer to 5001iX for each phase.
Controller
Controller i iX
AC mode X X
DC mode X X
AC+DC mode X
Transient programming X X
Arbitrary waveforms X
Measurements (standard) X X
Harmonic measurements X
Waveform acquisition X
Programmable Impedance X
IEEE / RS232 / USB X X
Storage
Non Volatile Mem. storage 16 instrument setups, 200 user dened waveforms
Waveforms
Waveform Types i Series II: Sine, iX Series II: Sine, Square, Clipped sine, User dened
User dened waveform storage Four groups of 50 user dened arbitrary waveforms of 1024 points for a total of 200 (One group can be active at a time)
System Interface
Inputs Remote shutdown, External Sync, Clock/Lock (option)
Outputs Function Strobe, Clock/Lock (option)
Protection
Over Load Constant Current or Constant Voltage mode
Over Temperature Automatic shutdown
10 kVA 2 37 26 18.5 13 208-240V
10 kVA 2 37 26 18.5 13 400-480V
15 kVA 1 111 78 55.5 39 208-240V
15 kVA 1 111 78 55.5 39 400-480V
15 kVA 3 37 26 18.5 13 208-240V
15 kVA 3 37 26 18.5 13 400-480V
www.ProgrammablePower.com176
i/iX Series Diagram
19.00
[48.26]
1.48
[3.76]
4.00
[10.16]
6.97
[17.70]
22.56
[57.30]
1.63
[4.14]
.19
[.48]
(OPTIONAL)
GENERAL DEVICES
RACK SLIDE
C300S-120-B308
1.18
[3.00]
16.80
[42.67]
3000–15000 VA
© 2009 AMETEK Programmable Power All rights reserved. AMETEK Programmable Power is the trademark of AMETEK Inc., registered in the U.S. and other countries. Elgar, Sorensen, California Instruments, and Power Ten are trademarks of AMETEK Inc., registered in the U.S.
858.458.0223
sales@ProgrammablePower.com 177
i/iX Series
Supplied with
User Manual, Programming Manual, Software (all on CD ROM) and RS232C serial cable.
Options
Option Code Description
-160 RTCA/DO-160D and EUROCAE test rmware. Refer to -160 option data sheet for details.
-400 400-480 Volt Line to Line AC input.
-411 IEC61000-4-11 test rmware. See also EOS1/3.
-413 IEC61000-4-13 Harmonics and Interharmonics test rmware and hardware.
-704 Mil Std 704D/E test rmware. Refer to -704 option data sheet for details. 704F Software
-EOS-1 IEC61000-4-11 Electronic Output Switch (1 phase) Includes -411 option. Refer to EOS data sheet for details.
-EOS-3 IEC61000-4-11 Electronic Output Switch (3 phase) Includes -411 option. Refer to EOS data sheet for details.
-LKM Clock/Lock Master
-LKS Clock/Lock Auxiliary
-LNS Internal AC Line Sync.
-XLS External AC Line Sync adaptor. (-LNS and XLS are mutually exclusive)
-MODE-iX Switches between 1 and 3 phase output modes, for 9003iX or 15003i/iX only. (Separate box)
OMNI-1-18i Impedance matching network for single phase 3001i/iX or 5001i/iX to support IEC-1000-3-3 icker tests.
OMNI-3-18i Impedance matching network for three phase 9003iX or 15003i/iX systems to support IEC-1000-3-3 icker tests.
OMNI-3-37i Impedance matching network for three phase 30003i/iX systems to support IEC-1000-3-3 icker tests.
-RMS Rackmount Slides.
-WHM Watt-Hour Measurement option.
-ABD Airbus Directive 0100.1.8 tests.
-AMD Airbus AMD24 tests.
-A350 Airbus A350 tests.
-AIRB Airbus test package (A380, A350, AMD24)
-B787 Boeing 787B3-0147 tests.
Cabinets Multi box iX Series II systems can be factory installed and wired in 19 inch cabinets. Cabinet congurations can be ordered by
preceeding the model number with a “C1-C4” prex. Contact factory for pricing and details.
www.ProgrammablePower.com178
Loading...