iQA Series
Portable Passive Intermodulation Analyzer
The iQA series Passive Intermodulation (PIM) analyzer is a feature rich, high power
PIM test solution. This eld proven analyzer enables network operators to improve
site performance by nding and eliminating sources of passive intermodulation at
the cell site. The design includes an integrated panel PC with intuitive touch screen
interface for performing tests and generating site reports.
Passive Intermodulation (PIM) Analyzer
PRODUCT FEATURES
― Rugged, reliable construction suitable for field use ― Fully configurable frequencies, powers and IM product
― Integrated polycarbonate transit case ― Spectrum analyzer mode
― Simple to operate touch screen interface ― Internal report generation
TECHNICAL SPECIFICATIONS |
SYSTEM
Measurement method Reverse (reected) PIM, 3rd, 5th, 7th and 9th order
Residual PIM < -115dBm/-158dBc max (<-125dBm/-168dBc typ.)
User interface ports 2x USB, x1 LAN 1x RF output (7-16 DIN female)
Display 8.4in (213mm) touch screen display
TRANSMITTER
ADVANTAGE
Transmit frequencies See model table
Frequency increment 50 kHz
Frequency accuracy ± 5ppm (max), aging ± 1ppm (max) after rst year
Power per tone (adjustable) 2x 2 to 20W (+33 to +43dBm)
Power accuracy (per tone) ± 0.5dB (max)
RECEIVER
Receive band (50kHz steps) See model table
Measurement noise oor < -128dBm
Measurement range -50dBm to -128dBm
© 2011 Kaelus Inc. All Rights Reserved.
|1|
www.kaelus.com
TECHNICAL SPECIFICATIONS CONTINUED |
ELECTRICAL
Mains power 115-230V, 50/60Hz AC
Power consumption 650W
MECHANICAL
Dimensions 19 x 18 x 12in (500 x 457 x 305mm)
Weight < 50lbs (22.7kg)
Cooling Forced air
ENVIRONMENTAL
Operating temperature range -10°C to +40°C
Storage temperature range -20°C to +60°C
Ingress protection (IP) IP20 (with lid open) IP21 (with lid closed)
Relative humidity 5% to 95% RH non-condensing
Mechanical shock 40G shock rating
MODELS |
DESCRIPTION TX RANGE RX RANGE (PIM)
iQA-700LB 700MHz (low) 728-746MHz 698-716MHz
iQA-700HB 700MHz (high) 728-757MHz 776-787MHz
iQA-850B 850MHz 869-894MHz 824-849MHz
iQA-900B GSM900 935-960MHz 890-915MHz
iQA-0901B EGSM 900 925-960MHz 880-915MHz
iQA-1800B DCS1800 1805-1880MHz 1710-1785MHz
iQA-1921B Dual band PCS/AWS 1930-1990MHz/2110-2155MHz 1710-1755MHz/1850-1910MHz
iQA-2101B UMTS (3rd & 7th order) 2110-2170MHz 1920-2080MHz
WARNING: Use of the portable PIM analyzer in a radiating mode, for
example when connected to an antenna not enclosed in an anechoic
environment, may be a violation of licensing regulations. Users should
have permission in advance, from any licensed operators that might be
affected by these tests. Furthermore, radiating high RF power can pose
a personnel risk.
Vertical orientation for easy access
to user interface.
© 2011 Kaelus Inc. All Rights Reserved. Rev_2_11
Self contained, ruggedized transport case.
www.kaelus.com
Specications subject to change without notice.
|2|