Teseq AG
Nordstrasse 11F 4542 Luterb ach Swit zerlan d
T + 41 32 6 81 40 40 F + 41 32 681 40 48
sales@tese q.com www.teseq.com
AUTOMATIC STEP TRANSFORMER
INA 6502
691-04 0A July 2 007
Technical specifications:
Input voltage UIN: 0 to 250 VAC,50/60 Hz
Output voltage UVAR: 4 steps:0% - 40% - 70% - 80% of UIN
Accuracy: ±5%
Voltage change with load:
100% output, 0 to 16 A less than 5%
80% output, 0 to 20 A less than 5%
70% output, 0 to 23 A less than 5%
40% output, 0 to 40 A less than 5%
Output current capability at
230 V input voltage: 16 Arms at 100% output
20 Arms at 80% output, for 5 s
23 Arms at 70% output, for 5 s
40 Arms at 40% output, for 5 s
Voltage selection: Software driven by Modula user interface
EUT power on/off function: Front panel switch with power on indicator
circuit breaker operated by Modula user interface
Connectors: Harting type HAN3A,compatible with Modula
safe power linking concept
Possible extensions: Connector for optional remote EUT power-off
switch,interlock connection to door switch
Instrument supply: Selectable 100 –110 VAC, 220–250 VAC, 15 VA, 47 to 63 Hz
Dimensions L x W x H: 460 x 200 x 160 mm (18.1 x 7.9 x 6.3”)
Weight: 15 kg (33 lbs) approx.
Cable: Power network receptacle to INA 6502 ~2 m (~79”)
(uses input cable delivered with Modula mainframe),
INA 6502 to Modula EUT power input ~2 m (~79”)
Control cable: 2 m (79”), 25 way sub D, twisted pair, shielded
(included in delivery)
Modula system requirements: Master controller revision 2 (copper interface)
Master controller fi rmware 1.17 or higher
MHC software, ModPDA version 2.30 or higher
WinModula version 2.30 or higher