iL Series User Manual
5.
Specification
Table
35 lists the specifications
s
the ambient temperature range of 0 to 40 ºC. Unless otherwise noted, specifications
are per phase for a sinewa
Hz to 1000 Hz and apply after a 30-minute warm-up period.
5.1
Performance Specifications
of the AC source. Specifications are warranted over
ve with a resistive load at an output frequency range of 45
Parameter
Phases mode:
Output Ratings
Power per phase:
Voltage Ranges (rms):
Maximum rms Current per phase:
Maximum Rep
Crest Factor (Current):
Output Frequency Range:
Constant Voltage Ripple and Noise:
Load
Regulation:
Line Regulation:
Maximum Total Harmonic Distortion:
Programming Accuracy (@ 25ºC ±5ºC)
Voltage (rms)
Frequency:
Phase:
Measurement Accuracy (@ 25ºC
±5ºC)
Phases:
rms Voltage:
rms Curr
Frequency:
Power (VA):
Power (Watts):
Power Factor:
AC Input
AC Input Frequency:
etitive Current per phase:
ent:
Voltage Range (Vac):
low range
high range
low range
high range
CI 3000iL CI 4500iL CI 4801iL
1 3 1 3 1
3000 VA
0-
150 V
0-
300 V
120 A
0.05% + 250 mV 0.05% + 250 mV 0.05% + 250 mV
0.1% + 50 mA 0.1% + 25 mA
0.01% + 0.01 Hz 0.01% + 0.01 Hz
0.15% + 5 VA 0.15% + 3 VA 0.15% + 9 VA
0.15% + 5 W 0.15% + 3 W 0.15% + 9 W
180-254 Vac (3Ø)
360-440 Vac (3Ø)
1000
VA
0-
150 V
0-
300 V
20 A
10 A
60 A 20 A 60 A 20 A 48 A
6.0 4.0 3.0
1% + 1%/kHz (>1 kHz - 5 kHz)
0.01 0.01 0.01
6.7 A
3.3 A
40 A
45 Hz - 5 kHz
1 % (45 Hz - 1 kHz)
1 3 1
4500 VA 1500 VA 4800 VA
0-
150 V
0-
300 V
30 A 10 A 32 A
15 A
120 A
-
60 dB (20 kHz-10 MHz)
0.1 % 0.3 %
0.15% + 0.3 V (45-100 Hz)
0.5% + 0.3 V (>100-500 Hz)
1% + 0.3 V (>500-5 kHz)
1º + 1º/kHz (>1 kHz - 5 kHz)
0.5 %
0.01% + 0.01 Hz
0.1º (45-100 Hz)
1º (>100-1000 Hz)
180-254 Vac (3Ø)
360-440 Vac (3Ø)
47- 63 Hz
0-
150 V
0-
300 V
5 A
40 A 96 A
45 Hz - 1 kHz
0.1% + 150mA
0.01% + 0.01
180-254 Vac
360-440 Vac
0-
150 V
0-
300 V
16 A
1 % (45Hz
1kHz)
(3Ø)
(3Ø)
Hz
-
54
Table35 : iL Series performance specifications
Rev B
California Instruments
5.2
IEC Measurement Specificati
ons
(4801iL only)*
Parameter Range
Frequency
Current (Low range)
Fundamental
Harmonics 2 - 49
Current (High range)
Fundamental
Harmonics 2 - 49
Flicker
Flicker perceptibility
Reference Impedance
Synchronization
Current shunt burden
Current harmonic smoothing filter
Pst
Integration time
50 Hz Operation
Rectangular measurement
window
Hanning measurement window
60 Hz Operation
Rectangular measurement
window
Hanning measurement window
* Specifications are in % of reading for 4801iL sinewave output with resistive load at
output frequency of 50 or 60 Hz in IEC mode of operation.
50 / 60 Hz
0 -
3.2 A
0 -
32 A
Sample rate
12.8 Khz
8.533 Khz
15.360 KHz
7.680 KHz
Compliant with IEC 868
Compliant with IEC 868
Window width
Accuracy (±)
0.03 % + 2 mA + 0.2%/KHz
0
.05 % + 3 mA + 0.2%/KHz
3 % (at 0.4
1, 5, 10 or 15 min
16 cycles
24 cycles
16 cycles
32 cycles
iL Series User Manual
0.03 % + 3 mA
0.05 % + 6 mA
and 796
< 1 ppm
0 Volts
1.5 sec
Acq.
overlap
None
50 %
None
50 %
H)
California Instruments
Table36 : IEC Measurement Specifications
Rev B
55