the ambient temperature range of 0 to 40 ºC. Unless otherwise noted, specifications
are per phase for a sinewa
Hz to 1000 Hz and apply after a 30-minute warm-up period.
5.1
Performance Specifications
of the AC source. Specifications are warranted over
ve with a resistive load at an output frequency range of 45
Parameter
Phases mode:
Output Ratings
Power per phase:
Voltage Ranges (rms):
Maximum rms Current per phase:
Maximum Rep
Crest Factor (Current):
Output Frequency Range:
Constant Voltage Ripple and Noise:
Load
Regulation:
Line Regulation:
Maximum Total Harmonic Distortion:
Programming Accuracy (@ 25ºC ±5ºC)
Voltage (rms)
Frequency:
Phase:
Measurement Accuracy (@ 25ºC
±5ºC)
Phases:
rms Voltage:
rms Curr
Frequency:
Power (VA):
Power (Watts):
Power Factor:
AC Input
AC Input Frequency:
etitive Current per phase:
ent:
Voltage Range (Vac):
low range
high range
low range
high range
CI 3000iLCI 4500iLCI 4801iL
13131
3000 VA
0-
150 V
0-
300 V
120 A
0.05% + 250 mV0.05% + 250 mV0.05% + 250 mV
0.1% + 50 mA0.1% + 25 mA
0.01% + 0.01 Hz 0.01% + 0.01 Hz
0.15% + 5 VA0.15% + 3 VA0.15% + 9 VA
0.15% + 5 W 0.15% + 3 W 0.15% + 9 W
180-254 Vac (3Ø)
360-440 Vac (3Ø)
1000
VA
0-
150 V
0-
300 V
20 A
10 A
60 A20 A60 A20 A48 A
6.04.03.0
1% + 1%/kHz (>1 kHz - 5 kHz)
0.010.010.01
6.7 A
3.3 A
40 A
45 Hz - 5 kHz
1 % (45 Hz - 1 kHz)
131
4500 VA1500 VA4800 VA
0-
150 V
0-
300 V
30 A10 A32 A
15 A
120 A
-
60 dB (20 kHz-10 MHz)
0.1 % 0.3 %
0.15% + 0.3 V (45-100 Hz)
0.5% + 0.3 V (>100-500 Hz)
1% + 0.3 V (>500-5 kHz)
1º + 1º/kHz (>1 kHz - 5 kHz)
0.5 %
0.01% + 0.01 Hz
0.1º (45-100 Hz)
1º (>100-1000 Hz)
180-254 Vac (3Ø)
360-440 Vac (3Ø)
47- 63 Hz
0-
150 V
0-
300 V
5 A
40 A96 A
45 Hz - 1 kHz
0.1% + 150mA
0.01% + 0.01
180-254 Vac
360-440 Vac
0-
150 V
0-
300 V
16 A
1 % (45Hz
1kHz)
(3Ø)
(3Ø)
Hz
-
54
Table35 : iL Series performance specifications
Rev B
California Instruments
5.2
IEC Measurement Specificati
ons
(4801iL only)*
ParameterRange
Frequency
Current (Low range)
Fundamental
Harmonics 2 - 49
Current (High range)
Fundamental
Harmonics 2 - 49
Flicker
Flicker perceptibility
Reference Impedance
Synchronization
Current shunt burden
Current harmonic smoothing filter
Pst
Integration time
50 Hz Operation
Rectangular measurement
window
Hanning measurement window
60 Hz Operation
Rectangular measurement
window
Hanning measurement window
* Specifications are in % of reading for 4801iL sinewave output with resistive load at
output frequency of 50 or 60 Hz in IEC mode of operation.
50 / 60 Hz
0 -
3.2 A
0 -
32 A
Sample rate
12.8 Khz
8.533 Khz
15.360 KHz
7.680 KHz
Compliant with IEC 868
Compliant with IEC 868
Window width
Accuracy (±)
0.03 % + 2 mA + 0.2%/KHz
0
.05 % + 3 mA + 0.2%/KHz
3 % (at 0.4
1, 5, 10 or 15 min
16 cycles
24 cycles
16 cycles
32 cycles
iL Series User Manual
0.03 % + 3 mA
0.05 % + 6 mA
and 796
< 1 ppm
0 Volts
1.5 sec
Acq.
overlap
None
50 %
None
50 %
H)
California Instruments
Table36 : IEC Measurement Specifications
Rev B
55
iL Series User Manual
5.3
Typical Specifications
Typical specifications as listed in
Table37 are not warranted but are descriptions of
typical performance determined either by design or type testing.
List Dwell Time:
Triggering Accuracy With Respect to Phase
Synchronization:
Trigger In Response Time:
Minimum Resolution for Dropout:
Output Response Time: (output change from
10% to 90% or 90% to 10% of its total
excursion with full resistive load)
Remote Inhibit Response Time:
Harmonic Measurement Time:
Miscellaneous
Recommended Calibration Interval:
Remote Sense Capability:
Waveform Table Horizontal Resolution:
Trigger In / Out characteristics
Trig
Out (HC TTL output):
Trig In (10 k
INH/FLT Characteristics
Maximum ratings:
INH terminals:
FLT terminals
Saveable Data (nonvolatile)
Instrument States:
pullup):
180-254 Vac (3Ø)18 A25 A
360-440 Vac (3Ø)10 A15 A
racy:
CI 3000iLCI 4500iLCI 4801iL
5800 VA/4100 W8900 VA/5900 W
0.2% + 40 mA 3Ø
0.2% + 80 mA 1Ø
2.5 mA 3Ø
7.5 mA 1Ø
6 mA 3Ø
5 mA 1Ø
0 -
1.08 X 106 s
Up to 10 Vrms can be dropped across each load lead.
16.5 VDC between INH terminals; FLT terminals; and
from INH terminals to chassis grou
300 V rms
80 mV
2 V
2.5 mA 3Ø
7.5 mA 1Ø
0.001 Hz
0.001º
10 mV
250
s
400
s
500
50
<1 ms
1 harmonic 100 ms;
all 50 harmonics
1 year
1024 points
Vol 0.8 V max. @ 1.25 mA
Voh 3.3 V max. @ 1.25 mA
Vil 0.8 V max. Vih 2 V min.
Iol 1.25 mA max.
Vol 0.5 V max.
Vil 0.8 V max.
Vih 2 V min.
tw 100 µs min.
td 4 ms typical
16 (0 to 15)
0.2% + 80 mA
7.5 mA
1.2 mA
0 -
4.30 X 105 s
100
s
200
s
s
s
2 s
nd
56
Rev B
California Instruments
iL Series User Manual
Parameter
User-defined waveforms:
List Data:
IEEE-488 Interface Capabilities
Language:
Interface:
RS-232C Interface Capabi
Baud rates:
Data formats:
Language:
Regulatory Compliance
Listing Pending:
Certified to:
Conforms to:
RFI Suppression
Complies with:
Dimensions
Height:
Width:
Depth:
Net weight:
Shipp
ing weight:
lities
CI 3000iLCI 4500iLCI 4801iL
12 (with 1024 data points in each)
1 to 100 points (for each list function)
SCPI (Standard Commands for Programmable
AH1, C0, DC1, DT1, E1, LE4, PP0, RL1, SH1, SR1,
300, 600, 1200, 2400, 4800, 9600
SCPI (Standard Commands for Programmable
262.6 mm (10.3 in.) add 12.7 mm (0.5 in.) for feet
Instruments);
Elgar 9012 PIP
TE6
7 bits even or odd parity;
8 bits without parity
Instruments)
UL 1244
CSA 22.2 N
CISPR 11, Group 1, Class A
425.5 mm (16.75 in.)
602 mm (23.7 in.)
87.7 kg (193 lbs.)
104 kg (230 lbs.)
o. 231
IEC 1010
Table37 : iL Series typical specifications
California Instruments
Rev B
57