Atec IFR-1900CSA User Manual

Fully Featured TIA/EIA-136 (TDMA) Test Solution
The IFR-1900 CSA provides you with the industrys only accepted test solution for TIA/EIA-136 analysis, including critical adjacent power measurements and power measurements down to -40 dBm, which allows the user to test the base station
without taking it off-line.
It is capable of performing the critical dual-mode analog/digital authentication and protocol compliance tests for TIA/EIA-136 dual mode mobiles.
As for flexibility, the IFR-1900 CSA provides the capability to perform both mobile and base station conformance testing. And with the VSELP and ACELP vocoder technology as standard features, the IFR-1900 CSA can handle todays latest technology.
The IFR-1900 CSA comes with a wide array of application software options. The AC1036 Protocol Conformance Test Software provides an excellent way to verify software conformance of TIA/EIA-136 mobiles. Other applications software supports automated tests for the most widely used base station applications.
AMPS Solutions
Engineered to be a true dual-mode test solution, the IFR-1900 CSA also incorporates AMPS and NAMPS mobile and base station compliance test features.
Full AMPS testing modes are available with the
IFR-1900 CSA
Automatic test routines and user defined print outs enhance manual mode testing for both mobiles and base stations.
Open control channel simulations, voice channel signaling, home/roam condition, home SID, SAT, DSAT, DST, DCC, SINAD reference points, RF power windows, and other AMPS/NAMPS functions and signaling routines allow complete AMPS and NAMPS system testing.
A Full Complement of Service Monitor Functions to 2 GHz.
The IFR-1900 CSA gives you full frequency domain analysis to 2 GHz with a fully featured spectrum analyzer and tracking generator built-in.
The IFR-1900 CSA also offers a full complement of standard service monitor features including a full span digitized oscilloscope to 1 MHz, DVM and SINAD functions, frequency and channel tables, selectable IF filters, and a wide variety of displays.
The IFR-1900 CSA gives you full featured service
monitor functions
IFR-1900 CSA
UWC-136 Digital PCS Radio Test Set
Engineered for maximum performance, the IFR-1900 CSA is an all in one PCS solution for todays dual band/dual mode mobile and base station equipment
Wireless - Radio Test Sets
The industry accepted simulator for TIA/EIA-136 conformance testing
Tri-Band, 400/800 MHz and 1900 MHz PCS test capable
Comprehensive TIA/EIA-136 conformance testing
Analog and digital authentication compliance testing option
TIA/EIA-136 hyperband handoff Fully automated remote testing
ability with RS-232 or IEEE-488 (GPIB) interfaces
Intuitive test set up screens for easy Guided user testing
VSELP and ACELP vocoder functions allow verification of voice quality
Full featured 2 GHz service monitor with spectrum analyzer and tracking generator
Standard constellation IQ display for quick assessment of digital mobile or base station transmitter modulation
IFR-1900 CSA
1
http://www.ifrinternational.com
In addition to the 2 GHz RF generator, the IFR-1900 CSA also provides full audio/data generator capabilities, full level control and measurement facilities and precision power control features for enhanced sensitivity and high accuracy testing needs.
Analog paging encoding/decoding, DTMF, tone coded squelch, digital squelch, AM modulation/demodulation along with two separate AF generators and cross band duplex gives added test versatility in a variety of wireless systems.
Software Options Make Complex Testing Simple
As with every IFR test set, you get the advantage of IFR applications engineering support.
Our comprehensive portfolio of application software options are designed to automate and expand the functionality of your instrument.
Plus, on-going software support means that you can easily upgrade your IFR-1900 CSA when test and service requirements change.
AC1009W - EasySpanTMis a Windows­based software utility which extracts spectrum analyzer and tracking generator traces from the IFR-1900 CSA.
AC1017 - AutoCell-Series II is a comprehensive program for FCC compliance testing of Lucent Series II cell sites.
AC1019 - EasySweepTMis a swept measurement utility designed to test antennas and transmission lines.
AC1020D - AutoCell NTD provides automated testing of Northern Telecom cell sites.
AC1021 - CellScanTMcellular utility software simplifies combiner alignment, monitoring RF levels and base stations on DAMPS, NT400 or PCS cellular channel sets.
AC1027 - AutoCell-882/884 is an autotest program for performing acceptance tests on Ericsson 884/882/882D/882M/882DM base stations.
EasySpan Software
Dynamic IQ Constellation Display Simplifies Analysis
The IFR-1900 CSA provides you with a dynamic constellation display for precise RF modulation analysis of DQPSK digitally modulated waveforms from 10 MHz to 2010 MHz. This unique IFR-1900 CSA feature gives a near real time display for testing and troubleshooting, an ability that points out the cause of the trouble in digital radios.
IQ Constellation display allows for comprehensive
digital modulation testing
Complex Functionality Made Easy
Even with its elaborate capabilities, the IFR-1900 CSA was developed to execute complex tests simply and with minimal operator training.
Using field-proven front panel and user man-machine interfaces, the IFR-1900 CSA gives you the performance and ease-of-use features that reduces your testing and training time.
Its test macro command programming language (TMAC) can be easily configured to perform automatic base station testing and remote terminal, singl
e and multi­mode, single and multiband equipment. This powerful capability allows you to create and save simple one button test routines for future use. This flexibility means you can create and execute complex and repeatable routines no matter what your level of expertise.
A new color VGA display gives IFR-1900 CSA users vivid screen clarity. Extensive use of softkeys reduces your complex cellular / PCS parametric and protocol tests to fast, simple and manageable routines.
Specification
(T/R) AND DUPLEX CONNECTOR Frequency Range
10 MHz to 2010 MHz
Resolution
100 Hz
Accuracy
Same as Master Oscillator
Range
-127 dBm to + 10 dBm into 50 (T/R Connector: -30 dBm maximum with reverse power present)
Resolution
0.1 dB
Accuracy
± 1.5 dB (-110 dBm)
Duplex Connector Input Protection
Alarm sounds when level exceeds +20 dBm.
EXTERNAL Generator IF Output Frequency Range
88 MHz to 90 MHz
Level Range
-30 dBm to +25 dBm into 50
Residual FM
<10 Hz RMS
SSB Phase Noise
<-94 dBc/Hz (20 kHz Offset)
Residual AM
<0.3% RMS (50 Hz to 15 kHz BW)
Non-Harmonics
<-50 dBc
Nominal Input Frequency for Generator IF In
90 MHz
Input Level
-26 dBm to +28 dBm into 50
Signal Bandwidth
8.5 MHz
System Gain
28 dB ± 7dB, from GEN IF Input to T/R Ports
INTERNAL FM Range
Off and ±100 Hz to ±100 kHz Dev.
Accuracy
± 5% (1 kHz to 20 kHz Dev, 1 kHz rate) ± 10% (1 kHz Dev and >20 kHz Dev, 1 kHz rate)
Resolution
100 Hz
Modulation Rate
1 kHz to 10 kHz - 5% accuracy
Waveforms
Sine, Square, Triangle
INTERNAL PHASE/QUADRATURE (IQ) RF Ranges
10 MHz to 2010 MHz
IQ Error Vector Magnitude
5% from ideal DQPSK waveform (TIA/EIA-136)
IQ Origin Offset
<-30 dBc
AF Generators #1 and #2 Range
10 Hz to 40 kHz
Resolution
0.1 Hz 2 kHz 1 Hz >2 kHz
Accuracy
±0.1%
Waveshapes
Sinewave, Square, Triangle, Ramp, Pulse
Frequency Range
10 Hz to 200 kHz (in 4 decade ranges)
Accuracy
Same as Master Oscillator
Resolution
0.1 Hz (10 Hz to 2 kHz) 1 Hz (>2 kHz to 20 kHz) 10 Hz (>20 kHz to 40 kHz)
Input Waveform
Sine or Square
External Level
0.5 VRMS to 30 VRMS (SINAD/BER input)
0.1 VRMS to 3.5 VRMS (EXT MOD input)
Audio Frequency Counter
AF Signal Generators
Modulation
RF Signal Generator
IFR-1900 CSA
IFR-1900 CSA
2
http://www.ifrinternational.com
Loading...