Atec IFI-ST81-50 User Manual

Page 1
Instruments for Industry 903 South Second Street Ronkonkoma, NY 11779 Phone 631 467-8400 Fax 631 467-8558 Email info@ifi.com
www.ifi.com
IFI TWT (CW) SERIES AMPLIFIERS
The TWT Amplifier (TWTA) monitors and transfers the power supply operating voltages and currents to a Front Panel Display. This aids the user in troubleshooting in the event of a failure. The TWTA indicates on the display where the fault has occurred.
Complete TWT Protection
Safety Requirement of IEC-348 VSWR Reflected Power Protection Cathode (Beam) Overcurrent Protection Helix Overcurrent Protection TWT Overtemperature Air Flow Fault Protection +/-Grid Undervoltage Protection (if applicable) Solid State Power Supply for Increased Reliability
Features
Front Panel Controls and Indicators Power On/Off Standby/Operate (Standby/RF On) (RF On/Operate) Local/Remote Fault Reset Air-cooled (Integrated Forced Air – self-contained) Modulation, AM, FM & PULSE IEEE 488 GPIB Remote Control RF Door Safety Interlock Self-diagnostic Circuitry Filament/Beam Elapsed Time Metering
Front Panel LCD Back-lit Display
Collector Current Grid Voltage (if applicable) Collector Voltage Cathode Voltage Helix Current Forward/Reflected Power Indication Filament Hours Beam Hours
Page 2
IFI SOLID STATE AMPLIFIERS
Wide instantaneous frequency range Gain control Backlit LCD display Total/Operate Elapsed Time Metering Self-diagnostic circuitry VSWR protection Safety Requirement of IEC-348 Unconditionally stable against load mismatches Forward /Reflected Power Indication IEEE 488 GPIB Remote Control RF Door Safety Interlock Air-cooled (Integrated Forced Air – self-contained) Open Circuit and Short Circuit Protection Modulation, AM, FM & PULSE Front Panel Controls and Indicators Standby/Operate Local/Remote EMI Filter built-in
Amplifiers are supplied with an AC line cord to accommodate the power source; an operation & maintenance manual; and amplifier performance test data.
The Front Panel is standard for RF Connectors and RF Sample Port. If this is not
convenient, please advise the location at the time of order. We will be happy to serve you. Thank you!
*GPIB IEEE-488 Remote Control is standard.
If this is not convenient, please review & advise the GPIB option at the time of order. These other available options are at no charge. Thank you! a. GPIB IEEE-488 Remote Control b. GPIB IEEE-488 and RS 232 Remote Control c. GPIB IEEE-488 and RS 422 Remote Control d. GPIB IEEE-488 and RS 485 Remote Control
Page 3
IFI Model ST81-50 Solid State/TWT (CW) Combination Amplifier Specifications
1-8 GHz (operable down to 0.8 GHz – specify if desired at time of order)
Bnd 1: 1-2 GHz (Solid State)
Frequency Range: Rated Power: 50 Watts minimum (70W typical) Gain @ rated power: 47 dB Prime Power: 100-240 VAC +/-10%, 50/60 Hz, Single Phase* Input/Output Impedance: 50 ohms (VSWR 2.0:1) RF Input/Output Connectors: Type N Female Temperature: 0º to 50º C (40º C @ 10,000 feet) Non-operating Temp: -20º to 70º C (50,000 feet max) Humidity: 95% without condensation Altitude: 10,000 feet Cooling System: Air cooled, self contained Modulation: AM/FM/Pulse Configuration: 19” Rack Mount; 19”W x 25.25”L x 10.5”H Spurious: -50dBc
**Harmonics (nominal): Features:
**-20dBc harmonics available with filters at an additional charge. The Filters can be external or band selectable via switches internal to the amplifier. The control can be via the front panel or over the GPIB remote bus.
Bnd 2: 2-8 GHz (TWT)
Band 1: 0.8-2.0 GHz, -20 dBc @ linear power (35-40 Watts) Band 2: 2-3GHz: -3 to –8 dBc @ Rated Power 3-6GHz: -8 to –15 dBc @ Rated Power 6-8GHz: -15 to –25 dBc @ Rated Power
VSWR Protection against an output mismatch
* Alternate Prime Power (specify at time of order)
* GPIB IEEE 488 Remote Control
Forward RF Sample Port on the Front Panel, type N-F
(specify front or rear at time of order)
Internal Pre-amplification to obtain rated output power with an input level of 0dBm or less.
RF Input/Output Connectors on the Front Panel
(Specify front or rear at time of order)
Internal Systems Diagnostics Elapsed Time Metering in hours RF Safety Interlock, type BNC Forward/Reflected Power Indication simultaneously on Front Panel display