IFI TWT (CW) SERIES AMPLIFIERS
The TWT Amplifier (TWTA) monitors and transfers the power supply operating voltages and 
currents to a Front Panel Display. This aids the user in troubleshooting in the event of a failure. 
The TWTA indicates on the display where the fault has occurred. 
Complete TWT Protection
Safety Requirement of IEC-348 
VSWR Reflected Power Protection  
Cathode (Beam) Overcurrent Protection 
Helix Overcurrent Protection 
TWT Overtemperature 
Air Flow Fault Protection 
+/-Grid Undervoltage Protection (if applicable) 
Solid State Power Supply for Increased Reliability 
Features
Front Panel Controls and Indicators 
Power On/Off 
Standby/Operate (Standby/RF On) (RF On/Operate) 
Local/Remote 
Fault Reset 
Air-cooled (Integrated Forced Air – self-contained) 
Modulation, AM, FM & PULSE 
IEEE 488 GPIB Remote Control 
RF Door Safety Interlock 
Self-diagnostic Circuitry 
Filament/Beam Elapsed Time Metering 
Front Panel LCD Back-lit Display
Collector Current 
Grid Voltage (if applicable) 
Collector Voltage 
Cathode Voltage 
Helix Current 
Forward/Reflected Power Indication 
Filament Hours 
Beam Hours 

IFI SOLID STATE AMPLIFIERS
Wide instantaneous frequency range 
Gain control 
Backlit LCD display 
Total/Operate Elapsed Time Metering 
Self-diagnostic circuitry 
VSWR protection 
Safety Requirement of IEC-348 
Unconditionally stable against load mismatches 
Forward /Reflected Power Indication 
IEEE 488 GPIB Remote Control 
RF Door Safety Interlock 
Air-cooled (Integrated Forced Air – self-contained) 
Open Circuit and Short Circuit Protection 
Modulation, AM, FM & PULSE 
Front Panel Controls and Indicators 
Standby/Operate 
Local/Remote  
EMI Filter built-in 
Amplifiers are supplied with an AC line cord to accommodate the power source; an 
operation & maintenance manual; and amplifier performance test data. 
The Front Panel is standard for RF Connectors and RF Sample Port. If this is not 
convenient, please advise the location at the time of order. We will be happy to serve you.  
Thank you! 
*GPIB IEEE-488 Remote Control is standard. 
If this is not convenient, please review & advise the GPIB option at the time of order. These 
other available options are at no charge. Thank you! 
a.  GPIB IEEE-488 Remote Control 
b.  GPIB IEEE-488 and RS 232 Remote Control 
c.  GPIB IEEE-488 and RS 422 Remote Control 
d.  GPIB IEEE-488 and RS 485 Remote Control 

IFI Model ST81-50 Solid State/TWT (CW) Combination Amplifier Specifications 
1-8 GHz (operable down to 0.8 GHz – specify if desired at time of order) 
Bnd 1: 1-2 GHz (Solid State) 
Frequency Range: 
Rated Power:  50 Watts minimum (70W typical) 
Gain @ rated power:  47 dB 
Prime Power:  100-240 VAC +/-10%, 50/60 Hz, Single Phase* 
Input/Output Impedance:  50 ohms (VSWR 2.0:1) 
RF Input/Output Connectors: Type N Female 
Temperature:  0º to 50º C (40º C @ 10,000 feet) 
Non-operating Temp:  -20º to 70º C (50,000 feet max) 
Humidity:  95% without condensation 
Altitude:  10,000 feet 
Cooling System:  Air cooled, self contained 
Modulation:  AM/FM/Pulse 
Configuration:  19” Rack Mount; 19”W x 25.25”L x 10.5”H 
Spurious:  -50dBc 
**Harmonics (nominal): 
Features: 
**-20dBc harmonics available with filters at an additional charge. The Filters can be external or band 
selectable via switches internal to the amplifier. The control can be via the front panel or over the GPIB 
remote bus. 
Bnd 2: 2-8 GHz (TWT) 
Band 1:  0.8-2.0 GHz, -20 dBc @ linear power (35-40 Watts) 
Band 2:  2-3GHz: -3 to –8 dBc @ Rated Power 
        3-6GHz: -8 to –15 dBc @ Rated Power 
        6-8GHz: -15 to –25 dBc @ Rated Power 
VSWR Protection against an output mismatch 
* Alternate Prime Power (specify at time of order) 
* GPIB IEEE 488 Remote Control 
Forward RF Sample Port on the Front Panel, type N-F 
(specify front or rear at time of order) 
Internal Pre-amplification to obtain rated output power with an input level of  
0dBm or less. 
RF Input/Output Connectors on the Front Panel 
(Specify front or rear at time of order) 
Internal Systems Diagnostics 
Elapsed Time Metering in hours 
RF Safety Interlock, type BNC 
Forward/Reflected Power Indication simultaneously on Front Panel display