Atec Fluke-5502A User Manual

5502A Multi-Product Calibrator
Robust, transportable solution to match your workload and budget
5502A features at a glance
Calibrates a wide variety of electrical test equipment
Robust protection circuits prevent costly damage from operator error
Ergonomically designed carrying handles make the 5502A easy to transport
Rugged carrying case with built-in handles and wheels and removable front/rear access doors for in-situ calibration in almost any environment
Current output that extends to 120 A when paired with the 52120A Transconductance Amplifier
Remarkably affordable
Practical solutions for calibrating in the lab or in the field
A full-functioned calibrator that covers a wide range of common workload
The 5502A Multi-Product Calibrator addresses common workload items like 3.5 and 4.5 digit digital multimeters and more. It comes with internal and external protection features that enable you to transport it easily and perform on-site or mobile calibration. The 5502A can also be fully automated with MET/CAL Calibration Management Software. It is the ideal calibrator for metrology professionals who need a solution for calibrating low-to-medium accuracy electrical instrumentation.
The 5502A sources direct voltage and current; alternating voltage and current with multiple waveforms and harmonics; simultaneous volt­age and current outputs or dual voltage outputs to simulate dc and ac power with phase control; as well as resistance, capacitance, thermocouples and RTDs. The 5502A can also measure thermocouples and thermocouple simulators. Two options add the capability to calibrate oscilloscopes to either 300MHz or 600 MHz.
Using the Fluke Calibration 52120A Transconductance Amplifier, the 5502A’s output current can be extended from 20.5 to 120 A; and with the use of 25 and 50 turn coils, it can calibrate instruments requiring up to 6000 A.
The 5502A calibrator covers many of the most common items in your workload, including:
Handheld and bench meters
(analog and digital) to 4.5 digits
Current clamps and clamp meters
Panel meters
Electronic thermometers
Chart recorders
Oscilloscope recorders
XY recorders
Data loggers
®
Plus
Fluke Calibrators
Multi-Product
Calibrators
Workload 5080A 5502A 5522A 5700A 5720A
Analog/Panel meters
High burden meters
Low burden meters
DMMs
Basic dc V accuracy 100 ppm 50 ppm 11 ppm 6.4 ppm 3.25 ppm
3.5 digits
(typ. ± 0.3% dcV)
4.5 digits
(typ. ± 0.025% dcV)
5.5 digits
(typ. ± 0.015% dcV)
6.5 digits
(typ. ± 0.0024% dcV)
7.5 digits
(typ. ± 12 ppm dcV)
8.5 digits
(typ. ± 3.9 ppm dcV)
Temperature/Pressure
RTD simulate
RTD measure
Thermocouple simulate
Thermocouple measure
Pressure modules opt
Oscilloscopes 1 channel
opt
300 MHz or
600 MHz
opt
600 MHz
opt
200 MHz to 600 MHz
1.1 GHz opt
2.1 GHz
3.2 GHz
6 GHz
25 ps fast edge
Safety testers
Hipot
Megohm meters opt
Installation
PATs
Continuity opt
Power/Energy
Wattmeters
Harmonic analyzers
Flicker meters PQ opt
Phase angle meters PQ opt
Power analyzers PQ opt
Power recorders
Other
Clamp meters
LCR meters CR only CR only
Process calibrators
Data acquisition
Non sine waveforms
RF millivolt meters opt opt
# of calibrator functions 8 11 11 5 5
200 MHz
Multifunction
Calibrators
3 5502A Multi-Product Calibrator
Loading...
+ 5 hidden pages