Atec Fluke-190 User Manual

Fluke 190 Series
ScopeMeter®Test Tools
34
Speed, performance and analysis power.
See more, fix more with color.
For the more demanding applications, the ScopeMeter 190 Series high-performance oscilloscopes offer specifications usually found on top-end bench instruments. With up to 200 MHz bandwidth and
2.5 GS/s real-time sampling, they’re ideal for engineers who need the full capabilities of a high-performance oscilloscope in a handheld, battery powered instrument.
Dual-input - 200, 100 or 60 MHz bandwidth
Up to 2.5 GS/s real-time sampling per input
Digital Persistence for analyzing complex dynamic
waveforms like on an analog scope (190C)
Large, high-resolution color or monochrome screen
Connect-and-View
range of manual trigger modes
Fast display update rate for seeing dynamic behavior
instantaneously
Automatic capture and replay of 100 screens
27,500 points per input record length using
ScopeRecord mode
TrendPlot paperless chart recorder for trend analysis
up to 22 days
Up to 1000 V independently floating isolated inputs
Waveform reference for visual comparisons and
automatic pass/fail testing (190C) of waveforms
1000 V CAT II and 600 V CAT III safety certified
Five hours rechargeable Ni-MH battery pack
See what’s really happening
With a maximum real-time sampling rate of
2.5 GS/s per input, you can see what really happens, with 400 ps resolution. Both inputs have their own digitizer, so you can simultaneously acquire two waveforms and analyze them with the highest resolution and detail. If an anomaly flashes by on the screen, just press the Replay button to see it again.
Easier identification of traces, everywhere
The full-color display makes identification of individual waveforms easier, particularly when displaying large amplitude or multiple overlapping waveforms on screen. On­screen color labels, meas­urements and warnings are clearly linked to specific waveforms.
See dynamic signal behavior instantaneously
ersistenc
ital P
The Dig helps to find anomalies and to analy
omplex dynamic sig
c
veforms amplitude distribution over time.
wa Digital Persistence uses multiple intensity
levels and user selectable decay time – it’s as if you’re looking at the display of an analog, real time oscilloscope! The fast
e mode (Fluke 1
nals by show
0C)
9
ze
ing the
automatic triggering and a full
display update rate that’s a standard on all models reveals signal changes instanta­neously, useful, for instance, when making adjustments to a system under test.
Automatic capture and replay of 100 screens
Scope users know how frustrating it is to see a one-time anomaly flash by – never to be seen again. Not with the ScopeMeter 190 Series! Now you can look back in time with a touch of the replay button. In normal use, the instrument continuously memorizes the last 100 screens. Each time a new screen is acquired, the oldest is discarded. At any moment you can “freeze 1
00 screens and scroll through pic ture-by-pic ture or repla as a “live animation. Cursors can be used for further analysis.
Deep memory for high­resolution ScopeRecord and Trendplot
The Sc points per input, for high-resolution rec ing of wa captures fast intermittents and glitches as short as 50 ns also stores events like motion profiles, U power supply and motor start-ups
” the last
-
­y
ord memor
opeRec
veform events up to 48 hours, and
. This c
y stores 2
ontinuous roll mode
7,500
.
ord
PS,
Telecommunications testing Application Note
(Literature code 2125182)
The telecommunications testing application note presents an example of using the ScopeMeter 190 color Pass/Fail function to find intermittent errors in waveforms. Go to www. fluke.com/ scopemeter for more.
In Trendplot or “paperless recorder” mode, you can plot the minimum, maximum peak and average measurement (DMM or Automatic Scope) values over time – up to 22 days. The two inputs can plot any combination of volts, amps, temperature, frequency and phase with time and date stamp to help lead you to the cause of those faults quickly.
Waveform Pass/Fail testing
Waveform reference (190B or 190C) allows an acquired trace to be stored and designated reference trace for visual comparisons, or it can be used as the reference for automatic Pass/Fail testing (190C only). Up to 100 individually matching (Pass) or non-matching (Fail) waveforms can be stored in the replay memory (190C only), allowing you to monitor your system’s behavior over a long period of time, without the need for you to attend!
Ordering information
92B
-1
E
K
LU
F
FLUKE-196B/003 ScopeMeter 100 MHz
FLUKE-196B/003S ScopeMeter 100 MHz
FLUKE-199B/003 ScopeMeter 200 MHz
E-199B/003S ScopeMeter 200 MHz
K
LU
F
-
FLUKE-196C/003 ScopeMeter 100 MHz
KE-196C/003S ScopeMeter 100 MHz
LU
F
FLUKE-199C/003 ScopeMeter 200 MHz
FLUKE-199C/003S ScopeMeter 200 MHz
W
/
B ScopeMeter 60 MHz
/003S
B/W with SCC kit
W
/
B
B/W with SCC kit
B/W
W w
/
B
color
color with SCC kit
color
olor w
c
ith S
ith S
C k
C
CC kit
it
For more information, go to www.MyFlukeStore.com
Loading...