Fluke 190 Series
ScopeMeter®Test Tools
34
Speed, performance and analysis power.
See more, fix more with color.
For the more demanding applications, the ScopeMeter
190 Series high-performance oscilloscopes offer
specifications usually found on top-end bench
instruments. With up to 200 MHz bandwidth and
2.5 GS/s real-time sampling, they’re ideal for engineers
who need the full capabilities of a high-performance
oscilloscope in a handheld, battery powered instrument.
• Dual-input - 200, 100 or 60 MHz bandwidth
• Up to 2.5 GS/s real-time sampling per input
• Digital Persistence for analyzing complex dynamic
waveforms like on an analog scope (190C)
• Large, high-resolution color or monochrome screen
• Connect-and-View
range of manual trigger modes
• Fast display update rate for seeing dynamic behavior
instantaneously
• Automatic capture and replay of 100 screens
• 27,500 points per input record length using
ScopeRecord mode
• TrendPlot paperless chart recorder for trend analysis
up to 22 days
• Up to 1000 V independently floating isolated inputs
• Waveform reference for visual comparisons and
automatic pass/fail testing (190C) of waveforms
• 1000 V CAT II and 600 V CAT III safety certified
• Five hours rechargeable Ni-MH battery pack
See what’s really happening
With a maximum real-time sampling rate of
2.5 GS/s per input, you can see what really
happens, with 400 ps resolution. Both
inputs have their own digitizer, so you can
simultaneously acquire two waveforms and
analyze them with the highest resolution
and detail. If an anomaly flashes by on the
screen, just press the Replay button to see
it again.
Easier identification of traces,
everywhere
The full-color display makes identification
of individual waveforms easier, particularly
when displaying large amplitude or multiple
overlapping
waveforms on
screen. Onscreen color
labels, measurements and
warnings are
clearly linked
to specific
waveforms.
See dynamic signal behavior
instantaneously
ersistenc
ital P
The Dig
helps to find anomalies and to analy
omplex dynamic sig
c
veforms amplitude distribution over time.
wa
Digital Persistence uses multiple intensity
levels and user selectable decay time – it’s
as if you’re looking at the display of an
analog, real time oscilloscope! The fast
e mode (Fluke 1
nals by show
0C)
9
ze
ing the
™
automatic triggering and a full
display update rate that’s a standard on all
models reveals signal changes instantaneously, useful, for instance, when making
adjustments to a system under test.
Automatic capture and replay of
100 screens
Scope users know how frustrating it is to
see a one-time anomaly flash by – never to
be seen again. Not with the ScopeMeter
190 Series! Now you can look back in time
with a touch of the replay button. In normal
use, the instrument continuously memorizes
the last 100 screens. Each time a new
screen is acquired, the oldest is discarded.
At any moment you
can “freeze
1
00 screens
and scroll
through pic
ture-by-pic
ture or repla
as a “live
animation.
Cursors can be
used for further analysis.
Deep memory for highresolution ScopeRecord
and Trendplot
The Sc
points per input, for high-resolution rec
ing of wa
captures fast intermittents and glitches as
short as 50 ns
also stores events like motion profiles, U
power supply and motor start-ups
” the last
-
y
”
™
™
ord memor
opeRec
veform events up to 48 hours, and
. This c
y stores 2
ontinuous roll mode
7,500
.
ord
PS,
Telecommunications testing
Application Note
(Literature code 2125182)
The telecommunications testing
application note presents an example
of using the ScopeMeter
190 color
Pass/Fail
function
to find
intermittent
errors in
waveforms.
Go to www.
fluke.com/
scopemeter
for more.
In Trendplot or
“paperless
recorder” mode,
you can plot
the minimum,
maximum peak
and average
measurement
(DMM or
Automatic Scope) values over time – up
to 22 days. The two inputs can plot any
combination of volts, amps, temperature,
frequency and phase with time and date
stamp to help lead you to the cause of
those faults quickly.
Waveform Pass/Fail testing
Waveform reference (190B or 190C)
allows an acquired trace to be stored
and designated reference trace for visual
comparisons, or it can be used as the
reference for automatic Pass/Fail testing
(190C only). Up to 100 individually
matching (Pass) or non-matching (Fail)
waveforms can be stored in the replay
memory (190C only), allowing you to
monitor your system’s behavior over a
long period of time, without the need
for you to attend!
Ordering information
FLUKE-192B/003 ScopeMeter 60 MHz
92B
-1
E
K
LU
F
FLUKE-196B/003 ScopeMeter 100 MHz
FLUKE-196B/003S ScopeMeter 100 MHz
FLUKE-199B/003 ScopeMeter 200 MHz
E-199B/003S ScopeMeter 200 MHz
K
LU
F
-
FLUKE-196C/003 ScopeMeter 100 MHz
KE-196C/003S ScopeMeter 100 MHz
LU
F
FLUKE-199C/003 ScopeMeter 200 MHz
FLUKE-199C/003S ScopeMeter 200 MHz
W
/
B
ScopeMeter 60 MHz
/003S
B/W with SCC kit
W
/
B
B/W with SCC kit
B/W
W w
/
B
color
color with SCC kit
color
olor w
c
ith S
ith S
C k
C
CC kit
it
For more information, go to www.MyFlukeStore.com