ELECTRICAL FAST TRANSIENT GENERATOR
FOR TESTS ACCORDING TO ...
> EN 61000-4-4 > EN 61000-6-1 > EN 61000-6-2 > IEC 61000-4-4 > IEC 61326 > IEC 61850-3
The EFT 500N8 is the state-of-the-art EFT/Burst tester with a built-in coupling/decoupling network for single phase or three-phase mains supply lines and a HV terminal to connect a capacitive coupling clamp. The spike frequency can be varied from as low as 100Hz to 1,000kHz. The EFT 500N8 is capable to generate 1,000 spikes per second or up to 150 spikes per burst. Its performance fully complies with IEC 61000-4-4:2004, IEC 61000-4-4 Amd.1 Ed.2:01/2010 and IEC 61000-4-4 Ed.3: 03/2012. Pre-programmed Standard Test routines and a number of selected User Test routines make the EFT 500N8 an optimum standalone solution for both testing during development and final testing of products and sub-assemblies.
HIGHLIGHTS
> Standalone Tester
APPLICATION AREAS
INDUSTRY
TELECOM
> 7,000V Burst voltage > Spike frequency 1MHz
MEDICAL
COMPONENTS
> Built-in 1ph or 3ph coupler > USB (optical link) and GPIB interface
BROADCAST
> Standard Test routines
RESIDENTIAL
www.emtest.com © EM TEST > PAGE 1/4
DATA SHEET > EFT 500N8 > 20130626
TECHNICAL DETAILS
EFT 500N8 MODELS
EFT 500N8 With 1-phase coupler;
250V/16A
EFT 500N8.1 With 3-phase coupler;
3 x 440V/32A Other couplers on special request
TEST LEVEL
Voltage range 1,000V - 7,000V Into 50ohm 500V - 3,500V Pulse shape 5/50ns into 50ohm load Rise time tr 5ns ± 30% Pulse width td 50ns ± 30% Pulse shape 5/50ns into 1,000ohm load Rise time tr 5ns ± 30% Pulse width td 35ns to 150ns Source impedance 50ohm ± 20% Polarity Positive/negative
TEST ROUTINES
Quick Start Immediate start; easy-to-use and
fast
User Test routines 1. Custom made test routines
2. Change voltage after T
3. Change frequency after T
4. Frequency sweep within a burst
5. Change burst duration after T
6. Randomly released bursts
7. Synchronous burst mode
8. Change polarity after T
Standard Test routines
1. As per IEC 61000-4-4, Level 1-5
2. Automatic test Level X to level Y
Service Service, set-up, self test
INTERFACES
Optical interface Opto link, 3 m cable
USB A connector Parallel interface IEEE 488, address 1 - 30 CN interface To control external CNI 503
TRIGGER
Automatic Automatic release of the bursts Manual Manual release of a single pulse External External release of a single pulse Burst duration Td = 0.1ms - 999.9ms Burst repetition
rate
Tr = 10ms - 9,999ms/man Tr <= 9,999ms => Auto Trigger
Tr > 9,999ms => Man Trigger Spike frequency f = 0.1kHz - 1,000kHz Test duration T = 0:01 min - 99:59 min
T > 99:59 min - endless
OUTPUT
Direct Via HV coax connector Coupler L, N and PE, all combinations DUT supply AC 250V/16A, 50/60Hz DUT supply DC 250V/10A DUT supply Other DUT supply voltages on
request
GENERAL DATA
Dimensions, weight
EFT 500N8: 19"/3HU, approx. 15kg EFT 500N8.1:
19"/6HU, approx. 19kg Supply voltage 115/230V +10/-15% Fuses 2x T 2AT (230V);
2x T 4AT (115V)
CRO Trigger 15V trigger signal for oscilloscope;
burst duration and pulse frequency can be checked