Atec E509A User Manual

Software selectable Surge waveforms:
10/1000
ms, 600V, 100A/side peak short-circuit current 10/1000ms, 1000V, 100A/side peak short-circuit current 10/1000ms, 1500V, 100A/side peak short-circuit current
Ability to add a complete range of modules:
– Surge and EFT simulator modules for all
– AC mains coupler/decouplers for single or
three-phase lines, to 600V rms and 100A continuous AC line current (the E509A waveforms are not coupled to the AC mains).
– I/O line coupler/decouplers for all types of lines,
including telecom and RS-232.
ECAT
®
Model E509A
Surge Simulator for Three-terminal 10/1000ms Telecom Testing
A plug-in module for ECAT systems for true three-terminal testing using 10/1000ms voltage and current waves, as required by Bellcore GR-1089-CORE.
FEATURES
The ECAT is configurable as a compact, standalone system with one test capability or as
an integrated, multiple capability tester.
Unparalleled safety features for high voltage testing, including a complete interlock system that not only disables simulator operation if activated, but completely removes AC mains power from the EUT, when using any KeyTek AC mains coupler/decoupler.
Automatic report generation using KeyTek’s exclusive Windows
®
-based software.
Modular system construction provides the ability
to upgrade test capabilities as requirements change or evolve.
Single port testing for Surge, EFT and PQF
mains coupled disturbances allows changing test modes without switching off power to the EUT. This avoids lost time due to re-initializing the EUT between tests.
SYSTEM BENEFITS
SPECIFICATIONS AND TOLERANCES
WAVEFORMS Waveforms: 10/1000ms, 50-600V -0/+15% peak
open-circuit voltage; 100A/side -0/+15% peak short-circuit current
10/1000ms, 50-1000V -0/+15% peak open-circuit voltage; 100A/side 0/+15% peak short-circuit current
10/1000ms, 50-1500V -0/+15% peak open-circuit voltage; 100A/side -0/+15% peak short-circuit current
Note:
All voltage and current specifications are minimum values, in accordance with Bellcore GR-1089-CORE.
Outputs are all true three-terminal outputs for testing either two or three-terminal devices or inputs. Outputs can be connected in parallel to double the available peak short-circuit current when testing two-terminal devices.
Front Time -30% /+0 for voltage; Tolerance: -40%/+0 for 1500V waveform and current
Duration -0/+50% for voltage; Tolerance: -0/+20% for current
Surge Repetition Rate: 1 shot/40 seconds
AVAILABLE OPTIONS
E509A-S: Adds an oscilloscope trigger for
any Surge network.
E509A-VI: Provides monitoring of the peak surge
voltages and currents at the output of the E509 module. All measurements are logged by software for diagnostic evaluation or Go/No-Go testing.
Note: If an ECAT coupler/decoupler is included, waveform monitoring is available at the output of the coupler/decoupler without the addition of Option E509-VI.
Model E509A
ECAT: AN EXTRAORDINARY CONCEPT IN EMC TESTING FOR VULNERABILITY TO SURGE, EFT AND POWER QUALITY.
ECAT is a totally integrated and modularized system
which offers unprecedented testing ease, accuracy and versatility to manufacturers, test houses, and anyone who will be testing for effects of Pulsed EMI.
ECAT is designed to test products according to a broad range of international standards developed by ANSI, the IEC, CENELEC and other agencies. The European Norms, developed by CENELEC, became mandatory on January 1, 1996 for all equipment shipped into the European Union or shipped across EU borders.
KPS-583A-11/97
A division of Thermo Voltek, a Thermo Electron company
KeyTek and ECAT are registered trademarks and PQF is a trademark of Thermo Voltek Corporation. ©Thermo Voltek. Specifications are subject to change without notice. Printed in USA.
One Lowell Research Center Lowell, Massachusetts 01852-4345 USA 1 800 753 9835 • Tel: 1 978 275 0800 • Fax: 1 978 275 0850 email: sales@keytek.com http://www.keytek.com
For additional ECAT®product literature call, email or fax the KeyTek sales department.
PHYSICAL
Height: 21cm (81/4”) Width: 42cm (16
1
/2”)
Depth: 52cm (20
3
/8”)
Weight: 16kg (35 lbs.) MINIMUM SYSTEM REQUIREMENTS
E100 series control center