DSP-4300 Digital CableAnalyzer
The DSP-4300 Digital
CableAnalyzer
total Cat 6 solution:
• Exceeds specification requirements for
Cat 5, Cat 5e and Cat 6 with Level III
Accuracy, independently verified by both
UL and ETL SEMKO
• Delivers more reliable PASS results with
the new revolutionary Permanent Link
Adapter – included with the DSP-4300
• Includes Cat 6 Channel Adapter and a
Channel/Traffic Adapter so you’re ready to
test Cat 6 channel limits with DSP accuracy
• Automatically diagnoses cabling faults and
shows exact locations in feet or meters
• Expanded 16 MB internal memory saves up
to a full day’s worth of testing (300 tests)
if you forget your multimedia card, or fill
up the card
• Download TIA-606A compliant Cable IDs
to the DSP-4300 in the office to save time
in the field and ensure accurate data
• Includes removable memory card and
LinkWare™ Cable Test Management
Software
• Optional Spool Test and Patch Cord Test
Adapters verify cable and patch cord
performance to the TIA/ISO Standards
And you have the assurance of performance,
reliability and standards compliance backed
and verified by both UL and ETL SEMKO.
™
offers
The revolutionary Permanent
Link Test Solution – included!
Our new DSP-LIA101S Permanent Link
Adapter delivers more
passes. Eliminates costly false fail results
due to worn twisted pair test leads. They
develop internal wear and tear you can’t see
and before you know it – your link test
fails. Falsely. That means wasted time in
trouble-shooting. And blown re-testing
costs. The new “non-twisted pair” design in
our Permanent Link Adapter solves all that.
PM06 Personality Module
certifies link and component
compliance
The new DSP-4300 Pernament Link
Adapter can be terminated with a choice
of several personality modules to offer
maximum flexibility and optimum test
results. The DSP-4300 includes the standard
PM06 Cat 6 Personality Module. The PM06
is the cabling industry's first centered,
shielded test plug designed to certify link
as well as connecting hardware compliance
to the TIA/EIA-568-B.2-1 Cat 6 standard.
The PM06 tests UTP, FTP and ScTP links
and is the recommended solution for Cat 6,
Cat 5e, Cat 5 and Cat 3 systems. No other
solution allows you to see the true performance of the cabling system to achieve an
“open” cabling system.
™
Channel Testing and Channel
Traffic Monitoring
The DSP-4300 has you covered for Channel
testing. Plug the Channel Adapter onto the
DSP-4300 and you can test with confidence.
Network SuperVision into high-performance
cabling systems.
DSP-4000 Series Selection Guide
DSP-4300 DSP-4100 DSP-4000PL DSP-4000
Standard DSP Package* • • • •
Cat 6/5E Permanent Link Adapters w/PM06 • ** • **
Cat 6/5E Channel Adapters • • • •
Cat 6/5E Channel/Traffic Adapter •
On-Board Memory–store up to 300 results • (summary test only; no graphical reports)
MMC Card & Card Reader • •
DSP-4300 Enhancement Kits
DSP-4300E1 DSP-4100 to DSP-4300 •
DSP-4300E0 DSP-4000 to DSP-4300 • •
*Standard DSP-4000 Series Package refers to Main and Remote test units, Talk Sets (2), Instrument Straps (2), DSP Calibration Module,
RS-232 Serial Cable, 8-pin modular to BNC adapter, Rechargeable NiMH battery packs (2), AC Adapter/Chargers (2), LinkWare Software,
Users Information CD-ROM, Getting Started Guide, Quick Reference Card, warranty registration card, and rugged soft case.
**Cat 5e Basic Link Adapters
Ordering Information
Model Items Included
DSP-4300 DSP-4300 Digital CableAnalyzer™
DSP-4000PL DSP-4000PL Digital CableAnalyzer™
DSP-4000 DSP-4000 Digital CableAnalyzer™
LinkWare LinkWare™ Software
Free download from Fluke Networks’ web site at www.flukenetworks.com/linkware
DSP-4000 Series Upgrades, Options and Accessories:
DSP-4300E1 Enhancement Kit: DSP-4100 to DSP-4300
DSP-4300E0 Enhancement Kit: DSP-4000 to DSP-4300
DSP-LIA101S Permanent Link Adapter Set with Cat 6 Personality Modules
DSP-LIA100S Permanent Link Adapter Set
DSP-LIA101 Permanent Link Adapter (1)
DSP-PCI-6S DSP Patch Cord Test Adapter Set
DSP-SPOOL DSP Spool Test Adapter (1)
DSP-LIA012S Cat 6/5e Channel Adapter Set
DSP-LIA013 Cat 6/5e Channel/Traffic Adapter (1)
DSP-PM06 Cat 6 Centered Personality Module
New
PM06
DSP-PMxx Personality Modules for IDC & Legacy Systems
DSP-FTA-420S Multimode Fiber Test Adapter
DSP-FTA430S Singlemode Fiber Test Adapter
DSP-FTA440S Gigabit Multimode Fiber Test Adapter
Includes expanded on-board memory (16 MB), software upgrade, LinkWare software,
User Information CD and a Certified Calibration
Includes 16 MB Multimedia card, PC card reader, expanded on-board memory (16 MB),
software upgrade, LinkWare software, User Information CD and a Certified Calibration
Includes two interface adapters that plug into the high performance connector of
the DSP-4000 Series and a set of the PM06 Cat 6 centered Personality Modules
(Cat 6 8-pin modular plugs) to test Cat 6, Cat 5e, Cat 5 and Cat 3 links.
Includes two interface adapters that plug into the high performance connector of
the DSP-4000 Series. Does not include any Personality Modules.
Includes one replacement adapter that plugs into the high performance connector
of the DSP-4000 Series. Does not include any Personality Modules.
PM06 is the first centered, shielded plug to test Cat 6 compliance and
interoperability. This global test solution supports all UTP, FTP and ScTP cabling
systems, (Cat 3, Cat, 5, Cat 5e and Cat 6). Approved by major connectivity
manufacturers, for complete list go to www.flukenetworks.com/pmmatrix
A wide selection of personality modules are available for IDC-type connectors as
well as legacy systems. For complete listing, go to www.flukenetworks.com/
legacypms
Uses LED light sources at 850 nm and 1300 nm
Uses laser light sources at 1310 nm and 1550 nm wavelengths
Uses a VCSEL source at 850 nm and laser source at 1310 nm
With Remote Connector Compensation™
2
(RC
) you’ll get the most accurate measurement results, giving you the true view of
the cabling system’s performance. Adding
the Channel/Traffic Adapter extends your
diagnostics and troubleshooting capabilities
all in one tester.
Expanded on-board memory
stores full day’s results
Left your memory card at the office? Don’t
worry, the DSP-4300 has 16 MB of built-in
internal memory, so you can test and save
up to 300 full graphical test results to
350 MHz. Insert a 32 MB memory card and
extend this to 600 results. Using the
removable multimedia card allows you to
keep the DSP on site. Take the memory
card back to the office or mail the card to
your customer.
Accurate cable ID download
Ac
saves time
No more clumsy and time-consuming textentry to enter cable IDs into the DSP. Just
download the cable IDs from any application that can generate a text file: for
example, a labeling software, a database
manager, a spreadsheet, LinkWare™
Software, or a third-party infrastructure
management package. Downloading the
cable IDs in advance saves time in the
field by eliminating the need to manually
enter cable IDs into the tester. It also
saves time in the office by ensuring that
test result IDs match exactly the cable IDs
in the company’s infrastructure management or labeling software.
Upgrade your DSP-4000 Series
Digital CableAnalyzer
See ordering information for upgrade
options for your DSP-4000 or DSP-4100.
NETWORKSUPERVISION
Fluke Networks
P.O. Box 777, Everett, WA USA 98206-0777
Fluke Networks operates in more than 50 countries
worldwide. To find your local office contact details,
go to www.flukenetworks.com/contact.
©2003 Fluke Corporation. All rights reserved.
Printed in U.S.A. 10/2003 1626542 A-ENG-N Rev D