DSP-4300 Digital CableAnalyzer
The DSP-4300 Digital 
CableAnalyzer 
total Cat 6 solution:
• Exceeds specification requirements for 
Cat 5, Cat 5e and Cat 6 with Level III 
Accuracy, independently verified by both 
UL and ETL SEMKO
• Delivers more reliable PASS results with 
the new revolutionary Permanent Link 
Adapter – included with the DSP-4300
• Includes Cat 6 Channel Adapter and a 
Channel/Traffic Adapter so you’re ready to 
test Cat 6 channel limits with DSP accuracy
• Automatically diagnoses cabling faults and 
shows exact locations in feet or meters
• Expanded 16 MB internal memory saves up 
to a full day’s worth of testing (300 tests) 
if you forget your multimedia card, or fill 
up the card
• Download TIA-606A compliant Cable IDs 
to the DSP-4300 in the office to save time 
in the field and ensure accurate data
• Includes removable memory card and 
LinkWare™ Cable Test Management 
Software 
• Optional Spool Test and Patch Cord Test 
Adapters verify cable and patch cord 
performance to the TIA/ISO Standards 
And you have the assurance of performance, 
reliability and standards compliance backed 
and verified by both UL and ETL SEMKO.
™
offers 
The revolutionary Permanent 
Link Test Solution – included! 
Our new DSP-LIA101S Permanent Link
Adapter delivers more 
passes. Eliminates costly false fail results 
due to worn twisted pair test leads. They 
develop internal wear and tear you can’t see 
and before you know it – your link test 
fails. Falsely. That means wasted time in 
trouble-shooting. And blown re-testing 
costs. The new “non-twisted pair” design in 
our Permanent Link Adapter solves all that.
PM06 Personality Module 
certifies link and component 
compliance
The new DSP-4300 Pernament Link 
Adapter can be terminated with a choice 
of several personality modules to offer 
maximum flexibility and optimum test 
results. The DSP-4300 includes the standard 
PM06 Cat 6 Personality Module. The PM06 
is the cabling industry's first centered, 
shielded test plug designed to certify link 
as well as connecting hardware compliance 
to the TIA/EIA-568-B.2-1 Cat 6 standard. 
The PM06 tests UTP, FTP and ScTP links 
and is the recommended solution for Cat 6, 
Cat 5e, Cat 5 and Cat 3 systems. No other 
solution allows you to see the true performance of the cabling system to achieve an 
“open” cabling system.
™
Channel Testing and Channel 
Traffic Monitoring
The DSP-4300 has you covered for Channel 
testing. Plug the Channel Adapter onto the 
DSP-4300 and you can test with confidence.
Network SuperVision into high-performance 
cabling systems.

DSP-4000 Series Selection Guide
DSP-4300 DSP-4100 DSP-4000PL DSP-4000
Standard DSP Package* • • • •
Cat 6/5E Permanent Link Adapters w/PM06 • ** • **
Cat 6/5E Channel Adapters • • • •
Cat 6/5E Channel/Traffic Adapter •
On-Board Memory–store up to 300 results • (summary test only; no graphical reports)
MMC Card & Card Reader • •
DSP-4300 Enhancement Kits
DSP-4300E1 DSP-4100 to DSP-4300 •
DSP-4300E0 DSP-4000 to DSP-4300 • •
*Standard DSP-4000 Series Package refers to Main and Remote test units, Talk Sets (2), Instrument Straps (2), DSP Calibration Module, 
RS-232 Serial Cable, 8-pin modular to BNC adapter, Rechargeable NiMH battery packs (2), AC Adapter/Chargers (2), LinkWare Software, 
Users Information CD-ROM, Getting Started Guide, Quick Reference Card, warranty registration card, and rugged soft case.
**Cat 5e Basic Link Adapters  
Ordering Information
Model Items Included
DSP-4300 DSP-4300 Digital CableAnalyzer™
DSP-4000PL DSP-4000PL Digital CableAnalyzer™
DSP-4000 DSP-4000 Digital CableAnalyzer™
LinkWare LinkWare™ Software
Free download from Fluke Networks’ web site at www.flukenetworks.com/linkware
DSP-4000 Series Upgrades, Options and Accessories:
DSP-4300E1 Enhancement Kit: DSP-4100 to DSP-4300
DSP-4300E0 Enhancement Kit: DSP-4000 to DSP-4300
DSP-LIA101S Permanent Link Adapter Set with Cat 6 Personality Modules
DSP-LIA100S Permanent Link Adapter Set 
DSP-LIA101 Permanent Link Adapter (1)
DSP-PCI-6S DSP Patch Cord Test Adapter Set
DSP-SPOOL DSP Spool Test Adapter (1)
DSP-LIA012S Cat 6/5e Channel Adapter Set
DSP-LIA013 Cat 6/5e Channel/Traffic Adapter (1)
DSP-PM06  Cat 6 Centered Personality Module
New
PM06
DSP-PMxx  Personality Modules for IDC & Legacy Systems
DSP-FTA-420S Multimode Fiber Test Adapter
DSP-FTA430S Singlemode Fiber Test Adapter
DSP-FTA440S Gigabit Multimode Fiber Test Adapter
Includes expanded on-board memory (16 MB), software upgrade, LinkWare software, 
User Information CD and a Certified Calibration
Includes 16 MB Multimedia card, PC card reader, expanded on-board memory (16 MB), 
software upgrade, LinkWare software, User Information CD and a Certified Calibration 
Includes two interface adapters that plug into the high performance connector of 
the DSP-4000 Series and a set of the PM06 Cat 6 centered Personality Modules 
(Cat 6 8-pin modular plugs) to test Cat 6, Cat 5e, Cat 5 and Cat 3 links.
Includes two interface adapters that plug into the high performance connector of 
the DSP-4000 Series. Does not include any Personality Modules. 
Includes one replacement adapter that plugs into the high performance connector 
of the DSP-4000 Series. Does not include any Personality Modules. 
PM06 is the first centered, shielded plug to test Cat 6 compliance and 
interoperability. This global test solution supports all UTP, FTP and ScTP cabling 
systems, (Cat 3, Cat, 5, Cat 5e and Cat 6). Approved by major connectivity 
manufacturers, for complete list go to www.flukenetworks.com/pmmatrix
A wide selection of personality modules are available for IDC-type connectors as 
well as legacy systems. For complete listing, go to www.flukenetworks.com/ 
legacypms
Uses LED light sources at 850 nm and 1300 nm
Uses laser light sources at 1310 nm and 1550 nm wavelengths
Uses a VCSEL source at 850 nm and laser source at 1310 nm
With Remote Connector Compensation™
2
(RC
) you’ll get the most accurate measurement results, giving you the true view of 
the cabling system’s performance. Adding 
the Channel/Traffic Adapter extends your 
diagnostics and troubleshooting capabilities 
all in one tester. 
Expanded on-board memory 
stores full day’s results
Left your memory card at the office? Don’t 
worry, the DSP-4300 has 16 MB of built-in 
internal memory, so you can test and save 
up to 300 full graphical test results to 
350 MHz. Insert a 32 MB memory card and 
extend this to 600 results. Using the 
removable multimedia card allows you to 
keep the DSP on site. Take the memory 
card back to the office or mail the card to 
your customer.
Accurate cable ID download
Ac
saves time 
No more clumsy and time-consuming textentry to enter cable IDs into the DSP. Just 
download the cable IDs from any application that can generate a text file: for 
example, a labeling software, a database 
manager, a spreadsheet, LinkWare™ 
Software, or a third-party infrastructure 
management package. Downloading the 
cable IDs in advance saves time in the 
field by eliminating the need to manually 
enter cable IDs into the tester. It also 
saves time in the office by ensuring that 
test result IDs match exactly the cable IDs 
in the company’s infrastructure management or labeling software.
Upgrade your DSP-4000 Series 
Digital CableAnalyzer
See ordering information for upgrade 
options for your DSP-4000 or DSP-4100.
NETWORKSUPERVISION
Fluke Networks
P.O. Box 777, Everett, WA USA 98206-0777
Fluke Networks operates in more than 50 countries 
worldwide. To find your local office contact details, 
go to www.flukenetworks.com/contact.
©2003 Fluke Corporation. All rights reserved. 
Printed in U.S.A. 10/2003 1626542 A-ENG-N Rev D