Signal In tegrity, Jitter, and Timing Ana lysis
Verification,Debug, andCharacterization ofSophisticated Designs
Debuggin
and DatacomIndustry Standards
Low-spee
FlexRay)
Investi
Power Measurementsand Analysis
Spectral Analysis
gand Compliance Testingof SerialData Streamsfor Teleco m
d SerialBus Design (I
gation ofTransient Ph enomena
2
C, SPI, RS-232, CAN, LIN, and
Data Sheet
Unmatched Performance for Greater Insight
Into Your Design to Get Your Work Done
Faster
The DPO7000 Series are the new generation of real-time digital phosphor
oscilloscopesand arethe industry’sbest solutionto
integrityissues facedby designersverifying, characterizing, debugging,and
testing sophisticated electronicdesigns.
The familyfeatures exceptional performance in signal acquisition and
analysis, operational simplicity, and unmatched debugging tools to
accelerate your day-to-day tasks. The largestscreen inthe industry and
theintuitive userinterface provideeasy accessto themaximum amountof
information.
the challenging signal
Unmatched Acquisition Performance
Signal Fidelity of Tektronix Oscilloscopes Ensures
Confidence in Your Measurement Results
High sample rateon allmodels, onall channels,to capturemore signal
details (tra nsients, imperfections, fastedges)
40GS/s onone channelon the2.5 GHzand 3.5 GHzmodels
Option 2SRto double th e maximum real-time sample rate for the
1 GHzmodel
High bandwidthup to 3.5GHz, matched across2, 3, or 4 channels
and enabled by Tektronix p roprietary DSP enhancement. The
lectable DSPfilter on each channel provides magnitude and
user-se
phase correctionplus extension to 3.5 GHzfor more accuratesignal
fidelity for complexmeasurements. TheDSP filteron eachchannel can
The DPO7000Series oscilloscopes include as astandard feature a
series of user-selectable bandwidthlimi
the instrument’sbandwidth roll-offcharacteristics, flatness, andphase
linearity within the new frequency range, thereby reducing the effects of
out-of-band noise onmeasurements. Now,
instrument fortheir highestbandwidth needs and easily optimizeit to
handle lower-frequ ency measurements aswell.
Verylow jitter noise floor and vertical accuracy for very accurate
measurements
Longacquisition toprovide moreresolution andlonger time sequence
Standard10 milliondata pointsper channelon theDPO7000 Series
Optional up to 500 million totaldata pointson 2.5GHz and3.5 GHz
models
Optionalup to250 milliontotal data pointson the500 MHzand 1 GHz
models
Easilymanage this deep record length, provide detailedcomparison
and analysisof multiple waveform segmentswith the MultiView
Zoom™feature. Automaticallyscroll through deeprecords visually,or
createa mathexpression toinstantly highlightdifferences
Highest-performance probing solutions for differentialand single-ended
voltage signalsas well ascurrent measurement, because accurate
designverification dependson high-bandwidthaccess tocritical signals
and high-fidelitysignal capture
t filters. These filters preserve
designers can purchaseone
User-selectablebandwidthlimiting choices.
Zoom in on four areasof interestsimultaneously to compare them.
Unmatched Versatility
Get the Most of Your Oscilloscope by Fully Controlling
its Waveform Acquisition and Display Parameters
Youhave thechoice ofthree horizontal timebase modesof operation. Ifyou
aresimply doingsignal explorationand want to interactwith alively signal,
youwill usethe Automatic or interactive defaultmode thatprovides youwith
the liveliest display updaterate. Ifyou want a precise measurementand
the highest real-time sample rate thatwill g ive you the most measurement
accuracy,then the Constant Sa mple Rate modeis foryou. Itwill maintain
the highest sample rate and provide the best real-time resolution. Thelast
modeis calledthe Manual mode becauseit ensuresdirect andindependent
control of the samplerate andrecord length.
With the MyScope®Feature, Create Your Own Control
Windows with Only the Controls, Features, and
Capabilities that You Care About
Easily createyour own personalized "toolbox" of oscilloscope features
in amatter of minutes u sing a simple, visual, drag-and-drop process.
Oncecreated, these custom control windowsare easilyaccessed through
a dedicatedMyScope button and menu selection on theoscilloscope
menu bar, justlike any othercontrol window. You can make an
button/
unlimited numb er of customcontrol windows,enabling each personwho
uses the oscilloscope ina sharedenvironment to havetheir ownunique
control window. MyScope control windows willbenefit all oscilloscope
users,eliminating theramp-up timethatmany facewhen returningto the lab
after not using anoscilloscope fora while,and enablesthe poweruser to
be far mo
re efficient. Everything you need isfound inone controlwindow
ratherthan havingto constantlynavigate through menuafter menuto repeat
similar tasks.
Digital Phosphor Oscilloscopes — DPO7000Series
3 modes of operationof thehorizontaltimebase.
Dragand drop menu items of interestto create the M yScope controlwindow.
www.tektronix.com 3
Data Sheet
Captureda
reportsus
ta into Microsoft Excelusing theunique Excel toolbar, and create custom
ing the Word toolbar.
With OpenChoice®Software, Customize Your Test and
Measurement System with Familiar Analysis Tools
Theanalysis andnetworking featuresofOpenChoice softwareadd flexibility
toWindows XPTektronixoscilloscopes: The WindowsXP RemoteDesktop
functionality enables remote monitoring of the instrument over the internet.
Using the
fast embedded bus, waveformdata canbe moveddirectly from
acquisitionto analysisapplications onthe Windowsdesktop atmuch faster
speeds thanconventional GPIB transfers. Implementationby Tektronix
of industry-stan dard protocols, suchas TekVISA™interface and ActiveX
controls, are included for using andenhancing Windows applications
for data analysisand documentation. Supportfor the DPO7000Series
is also a
IVI-COM instrumentdrivers areincluded to enable easy communication
with the oscilloscope usingGPIB, serialdata, andLAN connections from
programsrunning onthe instrumentor anexternalPC. Or,use theSoftware
Developer’s Kit(SDK)to helpcreate customsoftware toautomate multistep
processes in waveform collection and analysis withVisual BASIC,C, C++,
MATLAB,
LabVIEW,LabWindows/CVI, and othercommon Application
Development Environments(ADE). Integration ofthe oscilloscope with
external PCs and non-Windowshosts isalso supportedby theDPO7000
Series software solutions. Inaddition, the OpenChoice architecture
providesa comprehensive software infrastructure for faster,more versatile
operations. Datatransfer programs, such as the Excel or Wordtoolbar,
are used
to simplify analysis and documentation onthe Windowsdesktop
or onan external PC.
Maximizet
FastAcq ac
he probability of capturing elusive glitchesand otherinfrequent eventswith
quisitionmode.
Accelerate the Debug of Complex Electrical
Designs
FastAcq
Clearly Showing Imperfections
More thanjust color grading,FastAcq enabled byTektronixproprietary
DPX
waveforms persecond on all4 channels simultaneously,dramatically
increasing the probabilityof discoveringinfrequent faultevents. Andwith a
simple turn of the intensity knobyou canclearly see“a worldothers don’t
see,” b
vendorsclaim highwaveform capturerates forshort burstsof time, butonly
the DPO7000 Series, enabledby DPXtechnology, can deliver thesefast
waveform capture rates on asustained basis– savingminutes, hours, or
even days by q u ickly revealing thenature of faults s o sophisticated trigger
modes canbe appliedto isolate them.
Acquisition Mode Expedites Debugging by
®
acquisition technologycaptures signals up to morethan 250,000
ecause frequency of occurrence is color coded. Some oscilloscope
4 www.tektronix.com
Digital Phosphor Oscilloscopes — DPO7000Series
itches down to 200ps wide.
Isolategl
IsolateSetup and Hold violationsdown to360 ps.
The Abi
lity to Trigger an Oscilloscope on Events of
Interest is Paramount in Complex Signal Debug and
Validation
Whether you’retrying to find a systemerror or needto isolate a section
of a complex signalfor further analysis, like aDDR Read or Write burst,
TektronixPinpoint
uses SiliconGermanium (SiGe) technology to provide trigger
system
®
triggering providesthe solution. The Pinpoint trigger
sensitivity of up tothe bandwidth of the instrument,and allows selection
of most trigger typeson both A and Btrigger circuits. It cancapture very
narrow glitcheswith very littletrigger jitter. Other trigger systems offer
Easily tri
gger on a specificI
2
C address.
multiple trigger types only ona singleevent (Aevent), withdelayed trigger
(Bevent) selectionlimited toedge-type triggeringandoften donot providea
wayto resetthe triggersequence ifthe Bevent doesn’toccur. ButPinpoint
triggering providesa full suite of advancetrigger types on both Aand B
s w ith Reset triggeringto beginthe trigger sequenceagain aftera
trigger
specified time, state, or transition so that even events in themost complex
signals can be captured. Other oscilloscopes typically offer less than 20
trigger c ombinations; Pinpointtriggering offersover 1400 combinations,
all atfull performance.
WithEnhanced Triggering,youcan chooseto compensatefor the difference
intime thereis betweenthe triggerpath andthe displaypath andeliminate
virtually any trigger jitterat thetrigger point. In th is mode, thetrigger point
canbeus
ed as a measurementreference.
Trigger on the Most Relevant Bit Sequence of the
ry-standard Serial Bus
Indust
2
I
C (Int er-Integrated Circuit) triggering isa standardfeature and includes
StartC
Data Frame, in a10 bitor 7bit format with a specificselection to choose
whether ornot toinclude the R/Wbit.
SPI (SerialPeripheral Interface) triggering is a standard feature and
includes triggering ona datapattern withina user-definableframe.
RS-232 triggering is astandard feature.
ontroller Area Network) triggeringis an optional feature (Opt. LSA)
CAN (C
and includessynchronization tothe Start or End ofa CANframe on any
CAN high or CAN low signal, triggering on Type ofFrame (Data,Remote,
Overload),Identifier, Data, MissingAcknowledge, andBit Stuffingerror.
www.tektronix.com 5
Data Sheet
g on an analogHDTVtri-level sync signal and examininghorizontalblanking
Triggerin
interval.
Serialpatterntriggering to debug pattern-dependent issues.
Analog HDTV/EDTV Triggering for emergingstandards like1080i, 1080p,
720p, and480p aswell as standard vide o triggering onany line within a
field, alllines, all fields, odd or even fields forNTSC, SECAM, andPAL
videosignals. Inaddition, IRE andmV graticulescan beselected foreasier
measurem
entsand visualinspection. Thisis a standard feature.
Serial Pattern Triggering forNRZ serialdata streams with built-in clock
recovery
(available onmodels DPO7254 and DPO7354 only)to debug
serial architectures. The instrument can recoverthe clocksignal, identify
the tran sitions , and decodecharacters and other protocol data. With the
combination of the SerialTriggerand Protocol Decode software, youcan
see the captured bitsequences decoded intotheir wordsfor convenient
analysis(for 8b/10band otherencoded serialdata streams),or youcan set
ed e ncoded words forthe serial patterntrigger tocapture. This
the d esir
serialtrigger optioncovers NRZserial standardsup to1.25 Gb/s.
Lock Triggering addsa new dimensionto NRZ serialpattern
Pattern
triggering by enabling theoscilloscope totake synchronized acquisitions
of a long serialtest patternwith outstanding time base accuracy. Pattern
lock triggering can be used to removerandom jitter from long serial
data patterns. Effects of specific bit transitionscan be investigated,and
ingcan beused withmask testing. Thisfeature isincluded aspart of
averag
Option PTM on theDPO7254 and7354 models.
Unmatched Usability
The TekVPI™probe interfaceprovides versatilityand easeof useenabled
byintelligent bidirectionaloscilloscope-to-probe communication.
The DPO7000 Series are fast-responding instruments andcontain a
comprehensive suiteof featuressuch as atouch screen, shallow menu
structures, intuitivegraphical icons, knob-per-channelvertical controls,
support for rig ht mouse clicks, mouse wheel improvements, saving
of wavefo
rms and measurements ava ilable in Preview mode, and
Export/Save/Recall menuimprovements.
6 www.tektronix.com
Loading...
+ 14 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.