USB 2.0 Host Port on both the Front Panel and Rear Panel for Quick and
Easy Data Storage, Printing, and Connecting a USB Keyboard
USB 2.0 Device Port on Rear Panel for Easy Connection to a PC or
Direct Printing to a PictBridge
Integrated 10/100 Ethernet Port for Network Connection and Video Out
Port to Export the Oscilloscope Display to a Monitor or Projector
Optional Serial Triggering and Analysis
Automated Serial Triggering, Decode, and Search Options for I2C, SPI,
CAN, LIN, RS-232/422/485/UART, and I
Mixed Signal Design and Analysis (MSO Series)
Automated Triggering, Decode, and Search on Parallel Buses
Features & Benefits
Key Performance Specifications
500, 300, 100 MHz Ba ndwidth Models
2 and 4 Analog Channel Models
16 Digital Channels (MSO Series)
2.5 GS/s Sample Rate on All Channels
5 Megapoint Record Length on All Channels
>50,000 wfm/s M aximum Waveform Capture Rate
Suite of Advanced Triggers
Ease of Use Features
Wave Inspector®Controls Provide Easy Navigation and Automated
Search of Waveform Data
29 Automated Measurements, and FFT Analysis for Simplified
Waveform Analysis
®
I
TekVP
Probes for Automatic Scaling and Units
9 in. (229 mm) WVGA Widescreen Color Display
Small Footprint and Lightweight – Only 5 .8 in. (147 mm) deep and 9 lb.
(4 kg)
Probe Interface Supports Active, Differential, and Current
Multichannel Setup and Hold Triggering
MagniVu™ High-speed Acquisition Provides 121.2 ps Fine Timing
Resolution on Digital Channels
Optional Application Support
Power Analysis
HDTV and Custom Video Ana lysis
Feature-rich Tools for Debugging Mixed
Signal Designs
With the MSO/DPO3000 Mixed Signal Oscilloscope Series, you can
analyze up to 20 analog and digital signals with a single instrument to
quickly find and diagnose problems in complex designs. Bandwidths up
to 500 MHz and a minimum of 5x oversampling on all channels ensure
you have the performance you nee d for many of tod ay’s mainstream
applications. To capture long windows of signal activity while maintaining
fine timing resolution, the M SO/DPO3000 offers a deep record length of
5 Mpoints standard on all channels.
With Wave Inspector
and parallel bus analysis, and automated power analysis - the
serial
MSO/DPO3000 Oscilloscope Series from Tektronix provides the feature-rich
tools you need to simplify and speed debug of your complex design.
®
-compatible Printer
2
S/LJ/RJ/TDM
®
controls for rapid waveform navigation, automated
Data Sheet
Discover – F
of capturin
ast waveform capture rate - over 50,000 wfm/s - maximizes the probability
g elusive glitches and other infrequent events.
Comprehensive Features Speed Every Stage
of Debug
The MSO/DPO3000 Series offers a robust set of features to speed every
stage of debugging your design – from quickly discovering an anomaly and
capturing it, to se arching your waveform record for the event and analyzing
its characteristics and your device’s behavior.
Discover
To debug a design problem, first you must know it exists. Every
design engineer spends time looking for problems in their design, a
time-consuming and frustrating task without the right debug tools.
The MSO/DPO3000 Series o ffers the industry’s most complete visualization
of signals, providing fast insight into the real operation of yo ur device. A
fast waveform capture rate - greater than 50,000 waveforms per second enables you to see glitches and other infrequent transients within seconds,
ng the true nature of device faults. A digital phosphor disp lay with
reveali
intensity grading shows the history of a signal’s activity by intensifying areas
of the signal that occur more frequently, providing a visual display of just
how often anomalies occur.
Capture – Tr
complete se
quickly ca
iggering on a specific transmit data packet going across an RS-232 bus. A
t of triggers, including triggers for specific serial packet content, ensures you
pture your event of interest.
Capture
Discovering a device fault is only the first step. Next, you must capture the
event of interest to identify root cause.
The MSO/DPO3000 Series provides a complete set of triggers - including
runt, logic, pulse width/glitch, setup/hold violation, serial packet, and parallel
data - to help quickly findyourevent.Withuptoa5Mpointrecordlength,
you can capture many events of interest, even thousands of serial packets,
in a single acquisition for further analysis while maintaining high resolution
to zoom in
on fine signal details.
From triggering on specific packet content to automatic decode in multiple
data form
for the industry’s broadest range of serial buses – I
RS-232/422/485/UART, an d I
ats, the MSO/DPO3000 Series provides integrated support
2
C, SPI, CAN, LIN,
2
S/LJ/RJ/TDM. The ability to decode up to
two serial and/or parallel buses simultaneously means you gain insight into
system-level problems quickly.
To further help troubleshoot system-level interactions in complex embedded
systems, the MSO3000 Series offers 16 digital channels in addition to
its analog channels. Since the digital channels are fully integrated into
lloscope, you can trigger across all input channels, automatically
the osci
time-correlating all analog, digital, and serial signals. The MagniVu™
high-speed acquisition enables you to acquire fine signal detail (up to
121.2 ps resolution) around the trigger point for precision measurements.
MagniVu is essential for making accurate timing measurements for
setup and hold measurements, clock delay, signal skew, and glitch
erization.
charact
2 www.tektronix.com
Mixed Signal Oscilloscopes — MSO3000 Series, DPO3000 Series
Search–I2C decode showing results from a Wave Inspector search for Address value
50. Wave Inspector controls provide unprecedented efficiency in viewing and navigating
waveform data.
Search
Finding your event of interest in a long waveform record can be time
consuming without the right search tools. With today’s record lengths
pushing beyond a million data points, locating your event can mean scrolling
through thousands of screens of signal activity.
The MSO/DPO3000 Series offers the industry’s m o st comprehensive
search and waveform navigation with its innovative Wave Inspector
®
controls. These controls speed panning and zooming through your record.
With a unique force-feedback system, you can move from one end of your
record to
the other in just seconds. User marks allow you to mark any
location that you may want to reference later for further investigation. Or,
automatically search your record for criteria you define. Wave Inspector
will instantly search your entire record, including analog, digital, and serial
bus data. Along the way it will automatically mark every occurrence of your
defined event so you can quickly move between events.
Analyze – FF
tools speed
T analysis of a pulsed signal. A comprehensive set of integrated analysis
sverification of your design’s performance.
Analyze
Verifying that your prototype’s performance m atches simulations and meets
the project’s design goals requires analyzing its behavior. Tasks can range
from simple checks of rise times and pulse widt hs to sophisticated power
loss analysis and investigation of noise sources.
The MSO/DPO3000 Series offers a compre hensive set of integrated
analysis tools including waveform- and screen-based cursors, 29
automated measurements, advanced waveform math including arbitrary
equation e
diting, FFT analysis, and trend plots for visually determining
how a measurement is changing over time. Specialized application
support for serial bus analysis, power supply design, and video design and
development is also available.
For extended analysis, National Instrument’s LabVIEW SignalExpress™
Tektronix Edition provides over 200 built-in functions including time and
frequency domain analysis, limit testing, data logging, and customizable
reports.
www.tektronix.com 3
Data Sheet
Wave Inspector controls provide unprecedented efficiency in viewing, navigating, and
analyzing waveform data. Zip through your 5 Mpoint record by turning the outer pan
control (1). Get from the beginning to end in seconds. See something of interest and want
to see more details? Just turn the inner zoom control (2).
Wave Inspector®Navigation and Search
A 5 Mpoint record length represents thousands of screens of information.
The MSO/DPO3000 Series enables you to find your event in seconds with
Wave Inspector, the industry’s best tool for navigation and search.
Wave Inspector offers the following innovative controls:
Zoom/Pan
A dedicated, two-tier front-panel control provides intuitive c ontrol of both
zooming and panning. The inner control adjusts the zoom factor (or zoo m
scale); turning it clockwise activates zoom and goes to progressively higher
zoom factors, while turning it counterclockwise results in lowe r zoom factors
and eventually turning zoo m off. No longer do you need to navigate through
multiple menus to adjust your zoom view. The outer control pans the zoom
box across the waveform to quickly get to the portion of waveform you are
interested in. The outer control also utilizes force-feedback to determine
how fast to pan on the waveform. The farther you turn the oute r control, the
faster the zoom box moves. Pan direction is changed by simply turning the
control the other way.
Play/Pause
A dedicated Play/Pause front-panel button scrolls the waveform across the
display automatically while you look for anomalies or an event of int erest.
ack speed and direction are controlled using the intuitive pan control.
Playb
Once again, turning the control further makes the waveform scroll faster and
changing direction is as simple as turning the control the other way.
Search step
Search step 2: Wave Inspector automatically searches through the record and marks each
event with a hollow white triangle. You can then use the Previous and Next buttons to
jump from one event to the next.
1: You define what you would like to find.
User Marks
Press the Set Mark front-panel button to place one or more marks on
the waveform. Navigating between marks is as simple as pressing the
Previous ()andNext () buttons on the front panel.
Search Marks
The Search button allows you to automatically search through your lon g
acquisition looking for user-defined events. All occurrences of the event
are highlighted with search marks and are easily navigated to, using the
front-panel Previous () and Next () buttons. Search types include
pulse width/glitch, runt, logic, setup and hold, rise/fall time parallel
edge,
bus, and I
2
C, SPI, CAN, LIN, RS-232/422/485/UART, and I2S/LJ/RJ/TDM
packet conten t.
4 www.tektronix.com
Mixed Signal Oscilloscopes — MSO3000 Series, DPO3000 Series
Digital phosphor technology enables greater than 50,000 wfm/s waveform capture rate
and real-time intensity grading on the MSO/DPO3000 Series.
Digital Phosphor Technology
The MSO/DPO3000 Series’ digital phosphor technology provides you with
fast insight into the real operation of your device. Its fast waveform capture
rate – greater than 50,000 wfm/s – gives you a high probabil
ity of quickly
seeing the infrequent problems commo n in digital systems: runt pulses,
glitches, timing issues, and more.
Waveforms are superimposed with one another and waveform points that
occur more frequently are intensified . This quickly highlights the events
that over time occur mo re often or, in the case of infrequent anomalies,
occur less often.
With the MSO/DPO3000 Series, you can choose infinite persistence
or variable persistence, determining how long the previous waveform
acquisitions stay on screen. This allows you to determine how often an
anomaly is occurring.
Mixed Signal Design and Analysis
(MSO Series)
The MSO3000 Series Mixed Signal Oscilloscopes provide 16 digital
channels. These channels are tightly integrated into the oscilloscope’s user
interface, simplifying operation and making it possible to solve mixed-signal
issues easily.
The MSO Seri
time-corre
With the color-coded digital waveform display, groups are created by simply placing digital
channels t ogether on the screen, allowing the digital channels to be moved as a group.
You can set threshold values for each pod of eight channels, enabling support for up to
two different logic families.
Color-
es provides 16 integrated digital channels enabling you to view and analyze
lated analog and digital signals.
coded Digital Waveform Display
The MSO3000 Series has redefined the way you view digital waveforms.
One com
mon problem shared by both logic analyzers and mixed-signal
oscilloscopes is determining if data is a one or a zero when zo omed in far
enough that the digital trace stays flat all the way across the display. The
MSO3000 Series has color-coded digital tra ces, displaying ones in green
and zeros in blue.
www.tektronix.com 5
Data Sheet
White edges indicate additional information is available by zooming in. As shown here,
zooming in on the white edge reveals a hidden glitch.
The P6316 MSO probe offers two eight-channel pods to simplify connecting to your
device.
Once a group is formed, you can position all the channels contained in that
group collectively. This greatly reduces the normal setup time associated
with positioning channels individually.
The MagniVu high-resolution record provides 121.2 ps timing resolution, enabling you to
make critical timing measurements on your digital waveforms.
The multiple transition detection hardware of the MSO3000 Series will
show you a white edge on the display when the system detects multiple
transitions. White edges indicate that more information is available by
zooming in or acquiring at faster sampling rates. In most cases zooming in
will reveal the pulse that was not viewable with the previous settings. If the
white edge is still present after zoomi
ng in as far as possible, this indicates
that increasing the sample rate on the next acquisition will reveal higher
frequency information than the previous settings could acquire.
The MSO3000 Series simplifies channel setup by allowing you to group
digital waveforms and enter waveform labels by using a USB keyboard.
ly placing digital waveforms next to each other, they form a group.
By simp
MagniVu™ High-speed Acquisition
The main digital acquisition mode on the MSO3000 Series will capture up
to 5 M points at 500 MS/s (2 ns resolution). In addition to the main record,
the MSO30
00 provides an ultra high-resolution record called MagniVu which
acquires 10,000 points at up to 8.2 5 GS/s (121.2 ps resolution). Both main
and MagniVu waveforms are acquired on every trigger and can be switched
between in the display at any time, running or stopped. MagniVu provides
significantly finer timing resolution than comparable MSOs on the market,
instilling confidence when making critical timing measurements on digital
ms.
wavefor
P6316 MS
O Probe
This unique probe design offers two eight-channel pods, simplifying the
of connecting to the device-under-test. When connecting to square
process
pins, the P6316 can connect directly to 8×2 square pin headers s paced
on tenth-inch centers. When more attachment flexibility is required, you
can use the included flying lead sets and grab bers to clip onto surface
mount devices or test points. The P6316 offers outstanding electrical
characteristics applying on ly 8 pF of capacitive loading with 101 k input
nce.
impeda
6 www.tektronix.com
Mixed Signal Oscilloscopes — MSO3000 Series, DPO3000 Series
Triggering
clock and th
including
on a specific data packet going across an I
e blue waveform is data. A bus waveform provides decoded packet content
Start, Address, Read/Write, Data, and Stop.
2
C bus. The yellow waveform is
Serial Triggering and Analysis (Optional)
On a serial bus, a single signal often includes address, control, data, and
clock information. This can make isolating events of interest difficult. The
MSO/DPO3000 Series offers a robust set of tools for debugging serial
buses with automatic trigger, decode, and search for I
RS-232/422/485/UART, and I
2
S/LJ/RJ/TDM.
Serial Triggering
Trigger on packet content such as start of packet, specific addresses,
specific data content, unique identifiers, etc. on popular serial interfaces
2
such as I
Bus Displ
C, SPI, CAN, LIN, RS-232/422/485/ UART, and I2S/LJ/RJ/TDM.
ay
Provides a higher-level, combined view of the individual signals (clock, data,
ble, etc.) tha t make up your bus, making it easy to identify whe re
chip ena
packets begin and end and identifying subpacket components such as
address, data, identifier, CRC, etc.
Bus Decoding
Tired of having to visually inspect the waveform to count clocks, determine
if each bit is a 1 or a 0, combine bits into bytes, and determine the hex
value? Let the oscilloscope d o it for you! Once you’ve set up a bus, the
2
C, SPI, CAN, LIN,
Event table showing decoded Identifier, DLC, DATA, and CRC for every CAN packet in
alongacquisition.
MSO/DPO3000 Series will decode each packet on the bus, and display the
value in hex, binary, decimal (LIN only), signed decimal (I
2
S/LJ/RJ/TDM
only), or ASCII (RS-232/422/48 5/UART only) in the bus wavefo rm.
Event Table
In addition to seeing decoded packet data on the bus waveform itself, you
can view all captured packets in a tabular view much like you would see in
a software listing. Packets are time stamped and listed consecutively with
columns for each component (Address, Data, etc.).
Search
Serial triggering is very useful for isolating the event of interest, but once
you’ve captured it and need to analyze the surrounding data, what do
you do? In the past, users had to manually scroll through the waveform
counting and converting bits and looking for what caused the event. With
the MSO/DPO3000 Series, you can have the oscilloscope automatically
hrough the acquired data for user-defined criteria including serial
search t
packet content. Each occurrence is highlighted by a search mark. Rapid
navigation between marks is as simple as pressing the Previous ()and
Next () buttons on the front panel.
www.tektronix.com 7
Data Sheet
Safe operat
accurate an
ing area measurement. Automated power measurements enable quick and
alysis of common power parameters.
Power Analysis (Optional)
Ever increasing consumer demand for longer battery-life devices and for
green solutions that consume less power require power-supply designers
to characterize and minimize switching losses to improve efficiency. In
addition, the supply’s power levels, output purity, and harmonic feedback
into the power line must be characterized to comply with national and
power quality standards. Historically, making these and many
regional
other power measurements on an oscilloscope has been a long, manual,
and tedious process. The MSO/DPO3000 Series optional power analysis
tools greatly simplify these tasks, enabling quick and accurate analysis
of power quality, switching loss, harmonics, safe operating area (SOA),
modulation, ripple, and slew rate (di/dt, dv/dt). Completely integrated into
lloscope, the power analysis tools provide automated, repeatable
the osci
power measurements with a touch of a button; no external PC or complex
software setup is required.
ViewinganN
ability to r
TSC video signal. Notice the intensity-graded view provided by the DPO’s
epresent time, amplitude, and distribution of amplitude over time.
Video Design and Development
Many video engineers have remained loyal to analog oscilloscopes,
believing the intensity gradations on an analog display are the only way
to see certain video waveform details. The MSO/DPO3 000 Series fast
waveform capture rate, coupled with its intensity-graded view of the signal,
provides the same information-rich display as an analog oscilloscope, but
with much m
Standard features such as IRE and mV graticules, holdoff by fields, video
polarity,
MSO/DPO3000 Series the easiest to use oscilloscope on the market for
video applications. And with up to a 500 MHz bandwidth, four analog inputs,
and a built-in 75 inpu t termination, the MSO/DPO3000 Series provides
ample performance for analog and digital video use.
The MSO/DPO3000 Series video functionality is further extended with
the optional DPO3VID video application module. DPO3VID provides the
industry’s most complete suite of HDTV and custom (nonstandard) video
triggers
ore detail and all the benefits of digital scopes.
and an Autoset smart enough to detect video signals, make the
.
8 www.tektronix.com
Mixed Signal Oscilloscopes — MSO3000 Series, DPO3000 Series
The MSO/DPO3000 is designed to make your work easier. The large, high-resolution
display shows intricate signal details. Dedicated front-panel controls simplify operation.
A USB host port on the front panel allows you to easily transfer screenshots, instrument
settings, and waveform data to a memory stick.
Designed to Ma ke Your Work Easier
Large, High-resolution Display
The MSO/DPO3000 Series features a 9 inch (229 mm) widescreen,
high-resolution (800 × 480 WVGA) display for seeing intricate signal details.
Dedicated Front-panel Controls
Per-channel vertical controls provide simple and intuitive operation. No
longer do you need to share one set of vertical controls across all four
channels.
Connectivity
A USB host port on the front panel enables easy transfer of screenshots,
instrument settings, and waveform data to a memory stick. The rear
panel contains a second USB host port and a USB device port for
ling the oscilloscope remotely from a PC or for connecting a USB
control
keyboard. The USB device port can also be used to print directly to a
PictBridge
easy connection to networks and a Video Out port allows the oscilloscope
display to be exported to an external monitor or projector.
Compact Form Factor
A compact, portable form factor allows the MSO/DPO3000 Series to be
easily moved between labs and, with a depth of just 5.8 inches (147 mm),
it saves you valuable space on your test bench.
®
-compatible printer. An integrated 10/100 Ethernet port enables
The MSO/DPO3000 Series’ compact form factor frees up valuable space on your bench or
desktop.
TekVPI probe interface simplifies connecting your probes to the oscilloscope.
TekVPI®Probe Interface
The TekVPI probe interface sets the standard for ease of use in probing.
TekVPI probes feature status indicators and controls, as well as a probe
menu bu
tton right on the comp box itself. This b utton brings up a probe
menu on the oscilloscope display with all relevant settings and controls for
the probe. The TekVPI interface enables direct attachment of current prob es
without requiring a separate power supply. TekVPI probes can be controlled
remotely through USB, GPI B, or Ethernet, enabling more versatile solutions
in ATE environments.
www.tektronix.com 9
Data Sheet
NI LabVIEW SignalExpress™ Tektronix Edition is a fully interactive measurement
acquisition and analysis software developed jointly with National Instruments and
optimized for the MSO/DPO Series.
Extended Analysis
Acquiring data and measurements from the MSO/DPO3000 Series is as
simple as connecting a USB cable from the o s cilloscope to your PC. Key
software applications - NI LabVIEW SignalExpress™ Tektronix Edition
®
LE, Open
Choice
included standard with each oscilloscope to enable fast and easy direct
communication with your Windows PC.
Desktop, and Microsoft Excel and Word toolbars – are
OpenChoice®Desktop software enables seamless connection between the oscilloscope
and your PC.
NI LabVIEW SignalExpress Tektronix Edition LE enables you to instantly
acquire, generate, analyze, compare, import, and save measurement data
and signals using an intuitive drag-and-drop user interface that does not
require any programming. The optional Professional Version offers over
t-in functions that provide additional signal processing, advanced
200 buil
analysis, sweeping, limit testing and user-defined step capabilities.
le tasks, the included OpenChoice Desktop enables fast and easy
For simp
communication between the oscilloscope and your PC through USB or LAN
for transferring settings, waveforms, and screen images.
10 www.tektronix.com
Characteristics
Mixed Signal Oscilloscopes — MSO3000 Series, DPO3000 Series
Vertical Syst
CharacteristicMSO3012
Input Channels
Analog Bandwidth (-3 dB)
Calculated Rise Time
Internal DC Coupled0.5 div from DC to 50 MHz, increasing to 1 div at
External
(Auxiliary Input)
c
Description
rated bandwidth
200 mV from DC to 50 MHz increasing to 500 mV
at 250 MHz
Trigger Level Range
CharacteristicDescription
Any Channel±8 divisions from center of screen
External
(Auxiliary Input)
±8 V
Trigger Modes
ModeDescription
Edge
Sequence
(B-trigger)
Pulse Width
Runt
Logic
Setup and HoldTrigger on violations of both setup time and hold time between clock and data present on any of the input channels.
Rise/Fall TimeTrigger on pulse edge rates that are faster or slower than specified. Slope may be positive, negative, or either.
Video
Extended Video
(optional)
I2C (optional)Trigger on Start, Repeated Start, Stop, Missing ACK, Address (7 or 10 bit), Data, or Address and Data on I2C buses up to 10 Mb/s.
SPI (optional)Trigger on SS, MOSI, MISO, or MOSI and MISO on SPI buses up to 10.0 Mb/s.
CAN (optional)Trigger on Start of Frame, Frame Type (data, remote, error, overload), Identifier (standard or extended), Data, Identifier and Data, End of
I2S/LJ/RJ/TDM
(optional)
RS-232/422/485/UART
(optional)
LIN (optional)Trigger on Sync, Identifier, Data, Identifier and Data, Wakeup Frame, Sleep Frame, Errors such as Sync, Parity, or Checksum Errors up to
Parallel (available
on MSO models
only)
Positive or negative slope on any channel or front-panel auxiliary input. Coupling includes DC, AC, HF reject, LF reject, and noise reject.
Trigger Delay by Time - 8 ns to 8 s. Or Trigger Delay by Events - 1 to 9,999,999 events.
Trigger on width of positive or negative pulses that are >, <, =, or a specified period of time.
Trigger on a pulse that crosses one threshold but fails to cross a second threshold before crossing the first again.
Trigger when any logical pattern of channels goes false or stays true for specified period of time. Any input can be used as a clock to look for the
pattern on a clock edge. Pattern (AND, OR, NAND, NOR) specified for all analog and digital input channels defined as High, Low, or Don’t Care.
Trigger on all lines, odd, even, or all fields on NTSC, PAL, and SECAM video signals.
Trigger on 480p/60, 576p/50, 720p/30, 720p/50, 720p/60, 875i/60, 1080i/50, 1080i/60, 1080p/24, 1080p/24sF, 1080p/25, 1080p/30, 1080p/50,
1080p/60, and custom bi-level and tri-level sync video standards.
Frame, Missing ACK, or Bit Stuffing Error on CAN signals up to 1 Mb/s. Data can be further specified to trigger on ,<,=,>,,or aspecific
data value. User-adjustable sample point is set to 50% by default.
Trigger on Word Select, Frame Sync, or Data. Data can be further specified to trigger on ,<,=,>,, a specific data value, or inside
or outside of a range.
Maximum data rate for I2S/LJ/RJ is 12.5 Mb/s.
Maximum data rate for TDM is 25 Mb/s.
Trigger on Tx Start Bit, Rx Start Bit, Tx End of Packet, Rx End of Packet, Tx Data, Rx Data, Tx Parity Error, and Rx Parity Error up to 10 Mb/s.
1 Mb/s (by LIN definition, 20 kb/s).
Trigger on a parallel bus data value. Parallel bus can be from 1 to 16 bits in size. Binary and Hex radices are supported.
12 www.tektronix.com
Mixed Signal Oscilloscopes — MSO3000 Series, DPO3000 Series
Acquisition Modes
ModeDescription
Sample
Peak Detect
Acquire sampl
Captures glitches as narrow as 2 ns at all sweep
ed values.
speeds.
Averaging
Envelope
From2to512waveformsincludedinaverage.
Min-max envelope reflecting Peak Detect data over
multiple acquisitions.
Hi ResReal-time
and increa
Roll
Scrolls waveforms right to left across the screen at
boxcar averaging reduces random noise
ses vertical resolution.
sweep speeds slower than or equal to 40 ms/div.
Waveform Measurements
MeasurementDescription
CursorsWaveform and Screen.
Automatic
Measurements
29,ofwhichuptofourcanbedisplayedonscreen
at any one time. Measurements include: Period,
Frequency, Delay, Rise Time, Fall Time, Positive
Duty Cycle, Negative Duty Cycle, Positive Pulse
Width, Negative Pulse Width, Burst Width, Phase,
Positive Overshoot, Negative Overshoot, Peak
to Peak, Amplitude, High, Low, Max, Min, Mean,
Cycle Mean, RMS, Cycle RMS, Positive Pulse
Count, Negative Pulse Count, Rising Edge Count,
Falling Edge Count, Area and Cycle Area.
Measurement
Mean, Min, Max, Standard Deviation.
Statistics
Reference LevelsUser-definable reference levels for automatic
measurements can be specified in either percent
or units.
GatingIsolate the specific occurrence within an acquisition
to take measurements on, using either the screen,
or waveform cursors.
Power Measurements (Optional)
MeasurementDescription
Power Quality
Measurements
V
RMS,VCrest Factor
Power, Apparent Power, Reactive Power, Power
, Frequency, I
RMS,ICrest Factor
,True
Factor, Phase Angle.
Measurements
Harmonics
Power Loss: T
Energy Loss: T
THD-F, THD-R, RMS measurements.
, Conduction, Total.Switching Loss
on,Toff
, Conduction, Total.
on,Toff
Graphical and table displays of harmonics.
Test to IEC61000-3-2 Class A and MIL-STD-1399.
Ripple
Measurements
Modulation Analysis
V
and I
ripple
.
ripple
Graphical display of +Pulse Width, -Pulse Width,
Period, Frequency, +Duty Cycle, and -Duty Cycle
modulation types.
Safe Operating AreaGraphical display and mask testing of switching
device safe operating area measurements.
dV/dt and dI/dt
Cursor measurements of slew rate.
Measurements
Waveform Math
Characteristi
Arithmetic
Math Functions
FFT
c
Description
Add, subtract, m ultiply, and divide waveforms.
Integrate, Differentiate, FFT.
Spectral magnitude. Set FFT Vertical Scale
to Linear RMS or dBV RMS, and FFT Window
to Rectangular, Hamming, Hanning, or
Blackman-Harris.
A fully interactive measurement software
environment optimized for the MSO/DPO3000
Series, enables you to instantly acquire,
generate, analyze, compare, import, and save
measurement data and signals using an intuitive
drag-and-drop user interface that does not require
any programming.
Standard MSO/DPO3000 Series support for
acquiring, controlling, viewing, and exporting
your live signal data is permanently available
through the software. The full version (SIGEXPTE)
adds additional signal processing, advanced
analysis, mixed signal, sweeping, limit testing, and
user-defined step capabilities and is available for a
30-day trial period standard with each instrument.
OpenChoice
Desktop
®
Enables fast and easy communication between
a W indows PC and the MSO/DPO3000
Series. Transfer and save settings, waveforms,
measurements, and screen images. Included
Word and Excel toolbars automate the transfer
of acquisition data and screen images from
the oscilloscope into Word and Excel for quick
reporting or further analysis.
IVI DriverProvides a standard instrument programming
interface for common applications such as
LabVIEW, LabWindows/CVI, Microsoft .NET, and
MATLAB.
eScopeEnables control of the MSO/DPO3000 Series over
a network connection through a standard web
browser. Simply enter the IP address or network
name of the oscilloscope and a web page will be
served to the browser.
www.tektronix.com 13
Data Sheet
Display Charact eristics
Characteristi
Display Type
c
Description
9 in. (228.6 mm) wide format liquid crystal TFT
color display.
Display Resolution
800 horizontal × 480 vertical pixels (WVGA).
Waveform StylesVectors, Dots, Variable P ersistence, Infinite
Persistence.
GraticulesFull, Grid,
Cross Hair, Frame, IRE and mV.
FormatYT and XY.
Maximum Waveform
>50,000 wfm/s.
Capture Rate
Input/Output Ports
PortDescription
USB 2.0 High-speed
Host Port
Supports USB mass storage devices, printers, and
keyboards. One port available on rear panel and
one on front panel.
USB 2.0 High-speed
Device Port
Rear-panel connector allows for
communication/control of oscilloscope through
USBTMC or GPIB with a TEK-USB-488, and direct
printing to all PictBridge-compatible printers.
LAN Port
RJ-45 connector, supports 10/100Base-T.
Video Out PortDB-15 female connector, connect to show the
oscilloscope display on an external monitor or
projector.
Auxiliary Input
Probe Compensator
Output
Front-panel BNC connector. Input Impedance
1M. Max input 300 V
±450 V.
CAT II with peaks
RMS
Front-panel pins
Amplitude: 2.5 V
Frequency: 1 kHz
Trigger OutRear-panel BNC connector, provides a
negative-polarity pulse when the oscilloscope
triggers.
nsington Style
Ke
ock
L
ower Source
P
CharacteristicDescription
Power Source
Rear-panel security slot connects to standard
Kensington-style lock.
85 to 265 V ±10%
Voltag e
Power Source
45 to 440 Hz (85 to 265 V)
Frequency
Power Consumption
Optional TekVPI
External Power
Supply*
*1Required when total oscilloscope probe power usage exceeds 20 W.
®
1
120 W maximum
Output Voltage: 12 V
Output Current: 5 A
Power Consumption: 50 W
Physical Characteristics
Dimensions
mm
in.
Height203.28
Width416.616.4
Depth147.35.8
Weightkglb.
Net4.179.2
Shipping
Rackmount Configuration
8.6219
5U
Cooling Clearance2 in. (51 mm) required on left side and rear
of instrument
Environmental
CharacteristicDescription
Temperature
Operating0 ºC to +50 ºC
Nonopera
ting
-40ºCto+71ºC
Humidity
OperatingHigh: 30 ºC to 50 ºC, 5% to 45% Relative Humidity
Low: 0 ºC to 30 ºC, 5% to 95% Relative Humidity
Nonoperating
High:30ºCto50ºC,5%to45%RelativeHumidity
Low: 0 ºC to 30 ºC, 5% to 95% Relative Humidity
Altitude
Operating3,000 meters (9,843 feet)
Nonoperating
12,000 meters (39,370 feet)
Random Vibration
Operating0.31 G
3 axes, 30 minutes total
Nonoperating
2.46 G
3 axes, 30 minutes total
from 5 to 500 Hz, 10 minutes each axis,
RMS
from 5 to 500 Hz, 10 minutes each axis,
RMS
Regulatory
Electromagnetic
C Council Directive 2004/108/EC
E
Compatibility
SafetyUL61010-1:2004; CAN/CSA C22.2 No.
61010.1-04;
EN61010-1:2001; IEC61010-1:2001
14 www.tektronix.com
Ordering Information
Mixed Signal Oscilloscopes — MSO3000 Series, DPO3000 Series
DPO3000 Models
ProductDescription
DPO3012100 MHz, 2.5 GS/s, 5M record length,
DPO3014100 MHz, 2.5 GS/s, 5M record length,
DPO3032300 MHz, 2.5 GS/s, 5M record length,
DPO3034300 MHz, 2.5 GS/s, 5M record length,
DPO3054500 MHz, 2.5 GS/s, 5M record length,
2-channel digital phosphor oscilloscope
4-channel digital phosphor oscilloscope
2-channel digital phosphor oscilloscope
4-channel digital phosphor oscilloscope
4-channel digital phosphor oscilloscope
MSO3000 Models
ProductDescription
MSO3012100 MHz, 2.5 GS/s, 5M record length,
MSO3014100 MHz, 2.5 GS/s, 5M record length,
MSO3032300 MHz, 2.5 GS/s, 5M record length,
MSO3034300 MHz, 2.5 GS/s, 5M record length,
MSO3054500 MHz, 2.5 GS/s, 5M record length,
All Models Include: One P6139A 500 MHz, 10x Passive Probe per Analog Channel,
Front Cover (200-5052-xx), User Manual, Documentation CD (063-4104-xx),
OpenChoice
Software, Calibration Certificate Documenting Traceability to National Metrology
Institute(s) and ISO9001 Quality System Registration, Power Cord, Accessory
Pouch (016-2008-xx), Three-year Warranty. Please specify power plug and manual
language version when ordering.
®
Desktop Software, NI LabVIEW SignalExpress™ Tektronix Edition LE
2+16 channel mixed-signal oscilloscope
4+16 channel mixed-signal oscilloscope
2+16 channel mixed-signal oscilloscope
4+16 channel mixed-signal oscilloscope
4+16 channel mixed-signal oscilloscope
Application Modules
ModulesDescription
DPO3AUDIOAudio Serial Triggering and Analysis Module.
DPO3AUTOAutomotive Serial Triggering and Analysis Module.
DPO3COMPComputer Serial Triggering and Analysis Module.
DPO3EMB
DPO3PWR
DPO3VIDHDTV and Custom (nonstandard) Video Triggering
D
Enables triggering on packet-level information
2
on I
S, Left Justified, Right Justified, TDM, and
custom audio buses, as well as analytical tools
such as digital views of the signal, bus views,
packet decoding, search tools, and packet decode
tables with time stamp information.
Enables triggering on packet-level information on
CAN bus and LIN bus as well as analytical tools
such as digital views of the signal, bus views,
packet decoding, search tools, and packet decode
tables with time stamp information.
Enables triggering on packet-level information on
RS-232/422/485/UART buses as well as analytical
toolssuchasdigitalviewsofthesignal,busviews,
packet decoding, search tools, and packet decode
tables with time stamp information.
d Serial Triggering and Analysis Module.
Embedde
triggering on packet-level information on
Enables
2
PI buses as well as analytical tools such
I
CandS
tal views of the signal, bus views, packet
as digi
ng, search tools, and packet decode tables
decodi
me stamp information. Only two-wire SPI
with ti
t available on DPO3012, DPO3032 models.
suppor
Power Analysis Module. Enables quick and
accurate analysis of power quality, switching loss,
harmonics, safe operating area (SOA), modulation,
ripple, and slew rate (dI/dt, dV/dt).
Module.
MSO Models also Include: One P6316 16-channel logic probe and accessory kit.
www.tektronix.com 15
Data Sheet
Instrument Options
Power Plug Options
OptionDescription
Opt. A0
Opt. A1
Opt. A2
Opt. A3
Opt. A5Switzerland
Opt. A6
Opt. A10China
Opt. A11
Opt. A99
Language Options*
OptionDescription
Opt. L0
Opt. L1
L2
Opt.
Opt. L3German manual
Opt. L4Spanish manual
Opt. L5
t. L6
Op
Opt. L7Simplified Chinese manual
Opt. L8Traditional Chinese manual
Opt. L9
Opt. L10
Opt. L99
*2Language options include translated front-panel overlay for the selected language(s).
Service Options*
OptionDescription
Opt. C3Calibration Service 3 years.
Opt. C5Calibration Service 5 years.
Opt. CA1
Opt. D1Calibration Data Report.
Opt. D3Calibration Data Report 3 years (with Opt. C3).
Opt. D5Calibration Data Report 5 years (with Opt. C5).
Opt. R5Repair Service 5 years (including warranty).
*3Probes and accessories are not covered by the oscilloscope warranty and Service Offerings. Refer to the
datasheet of each probe and accessory model for its unique warranty and calibration terms.
North America
Universal Euro
United Kingdom
Australia
Japan
India
No power cord
2
English manual
French manual
Italian manual
Japanese manual
Portuguese manual
Korean manual
Russian manual
No manual
3
Provides a single calibration event, or coverage
for the designated calibration interval, whichever
comes first.
Recommended P robes
ProbeDescription
TAP1500
TAP1500X2
1.5 GHz TekVPI
Bundle of Two 1.5 GHz Active Probes, single
®
active voltage probe.
ended with TekVPI Interface.
TDP0500
500 MHz TekVPI differential voltage probe with
±42 V differential input voltage.
TDP1000
1 GHz TekVPI differential voltage probe with ±42 V
differential input voltage.
TCP0030120 MHz TekVPI 30 Ampere AC/DC current probe.
TCP015020 MHz TekVPI 150 Ampere AC/DC current probe.
NEX-HD2HEADERMictor connector breakout to 0.1 in. header pins.
DPO3PWRBND
Power Solution
Bundle
Includes P5205 and TDP0500 differential voltage
probes, TCP0030 current probe, TPA-BNC
adapter, deskew pulse generator (TEK-DPG),
deskew fixture, and power analysis module
(DPO3PWR) in a hard-sided carrying case. Bundle
discount reflectedinprice.
FPGAView-xxMSO Support for Altera and Xilinx FPGAs
TEK-USB-488GPIB-to-USB adapter
ACD4000Soft Transit Case
HCTEK4321Hard Transit Case (requires ACD4000)
RMD3000Rackmount K it
*5Required when total oscilloscope probe power usage exceeds 20 W. Power cord not included.
Warranty
Three-year warranty covering all parts and labor, excluding probes.
Product(s) are manufactured in ISO registered facilities.
16 www.tektronix.com
Product(s) complies with IEEE Standard 488.1-1987, RS-232-C, and with Tektronix
Standard Codes and Formats.
Mixed Signal Oscilloscopes — MSO3000 Series, DPO3000 Series
www.tektronix.com 17
Data Sheet
Contact Tektronix:
ASEAN / Australa
Balkans, Israel, South Africa and other ISE Countries +41 52 675 3777
Central East Eu
Mexico, Central/South America & Caribbean 52 (55) 54247900
rope, Ukraine, and the Baltics +41 52 675 3777
Central Europe & Greece +41 52 675 3777
Luxembourg +44 (0) 1344 392400
Middle East,
For other areas contact Tektronix, Inc at: 1 (503) 627-7111
Asia, and North Africa +41 52 675 3777
The Netherlands 090 02 021797
People’s Rep
United Kingdom & Ireland +44 (0) 1344 392400
ublic of China 86 (10) 6235 1230
Republic of
sia (65) 6356 3900
Austria +41 52 675 3777
Belgium 07 81 601
Brazil +55 (11) 40669400
Canada 1 (800) 661-5625
Denmark +4580881401
Finland +41526
France +33(0)169868181
Germany +49 (221) 94 77 400
Hong Kong (852
India (91) 80-42922600
Italy +39 (02) 25086 1
Japan 81 (3) 67
Poland +41 52 675 3777
Portugal 80 08 12370
Korea 82 (2) 6917-5000
Russia & CIS +7 (495) 7484900
South Africa +27 11 206 8360
Spain (+34)
Sweden 020 08 80371
Switzerland +41 52 675 3777
Tai wan 886 (
USA 1 (800) 426-2200
75 3777
) 2585-6688
14-3010
Norway 800 16098
901 988 054
2) 2722-9622
Updated 30 October 2008
66
www.tektronix.com
For Further Information. Tektronix maintains a comprehensive, constantly expanding
collection of application notes, technical briefs and other resources to help engineers working
on the cutting edge of technology. Please visit www.tektronix.com