2004 General Electric Company. All rights reserved.
GEIT-20208-s-AE (06/04)
We reserve the right to technical modifications without prior notice.
GEInspectionTechnologies.com
Base Instrument Package
DM4E Ultrasonic Thickness Gauge
Two 1.5V AA Alkaline Batteries
Carrying Case
Operating Instruction Card
Operating Manual
Certificate of Calibration
Accessories
RC-984
Rubber instrument case with prop-up stand,
adjustable neck and wrist straps, and hanging
loop
FB-579
Field Accessory Belt with removable pouches
LCC-326
Locking Transport and Storage Case
HTC-010
HiTempco Couplant (2 oz. tube)
Specifications
Operating Principle
Ultrasonic pulse/echo
DIALOG Intelligent Transducers -- automatically recognized for optimum performance. *2-pt. calibration required, auto probe zero inoperable. Note: Other standard probe models are available and
“special probes” are developed in our Application Lab to satisfy unique requirements.
• DM4E is covered by a full two year warranty on parts and labor
Krautkramer DM4E
Probe Zero Adjustment
Automatic, or manual 2-pt. calibration
V-Path Correction
Automatic, microprocessor controlled
Measuring Range
0.25"- 20.00" (.64-500mm) depending on probe,
material, surface condition, and temperature
Displayed Resolution
.001 or .01 up to 9.999 inches, .01 above
9.999 inches; .01 or .1 up to 99.99 mm,
.1 above 99.99 mm
Measurement Update Rate
4 Hz; 25 Hz in Minimum Capture Mode
Gain
Automatic
Material Velocity Range
39,000 to 393,700 in./sec.;
1000 to 9999 m/sec.
Receiver Bandwidth
1 MHz to 10 MHz (–3 dB)
Display Type
4 digit LCD, .5" (12.7 mm) high, direct drive,
with electroluminescent backlight
Power Supply
2 ea. 1.5V AA alkaline cells
Battery Life (operating time)
Up to 200 hours @25% duty cycle without
backlight
Auto Shutoff
After 3 minutes of non-use
Operating Temperature Range
+10°F to +120°F (-10°C to +50°C)
Size ( L x W x D)
5.8" x 3.0" x 1.4" (at thickest point);
146.0 mm x 76.2 mm 34.3 mm
Weight
9 oz. (255 g) including batteries
Hazardous Area Operation
Safe operation as defined by MIL-STD-810E,
method 511.3, procedure.
Application and Description Model Probe
Cable
Contact
Diameter
Frequency Measuring Range
In Steel
Temperature
Range
High Sensitivity Fingertip
FH2E Potted
380” (9.6 mm)
7.5
.030” - 2.0”
(.75 - 50 mm)
< 130° F
(< 538° C)
High Temperature
HT400 KBA533/536 .500” (12.7 mm) 5.0
.030"- 10.0"
(.76 - 254 mm)
<1 000° F
(< 538° C)
Thin Materials
DA312 KBA532 .300” (.76 mm) 10.0
.025"- 1.0"
(.64 - 25 mm)
< 130° F
(< 54° C)
High Penetration
DP 104 KBA532 1.25” (31.8 mm) 1.0
.200" (5 mm)
minimum
< 130° F
(< 54° C)
Penetration
DA 303 KBA533 .635” (16.2 mm) 2.0
.200" (5 mm)
minimum
< 140° F
(< 60° C)
General Purpose
DA 301 KBA533 .475” (12.1 mm) 4.0
.050"- 8.00"
(1.2 - 200 mm)
< 140° F
(< 60° C)
Wear Resistant
FH2E WR Potted .550” (14.0 mm) 7.5
.030"- 2.0"
(.75 - 50 mm)
< 130° F
(< 54° C)
High Sensitivity Fingertip
FH2E D
★
Potted .380” (9.6 mm) 7.5
.030"- 2.0"
(.75 - 50 mm)
< 130° F
(< 54° C)
General Purpose
DM 401 GP
★
KBA533/
533A
.700” (17.8 mm) 5.0
.060"-8.0"
(1.5 –200mm)
< 300° F
(< 148° C)
General Purpose
DM 411 GP
★
DA 233 .700” (17.8 mm) 5.0
.060"-8.0"
(1.5 –200mm)
< 300° F
(< 148° C)
Small Dia. Fingertip
FH2E M Potted .280” (721 mm) 7.5
.0.030"-2.0"
(.75-50mm)
< 130° F
(< 54° C)
3 mm Footprint
DA 312B16* Potted .120” (3.0 mm) 10.0
.025"- .500"
(.6 - 13 mm)
< 130° F
(< 54° C)
GE Inspection Technologies
Ultrasonics