design that results in two rackmount proles according to output power
t&YUFSOBM4IVUEPXO"OFYUFSOBMTIVUEPXOUP
inhibit the output
t4FRVFODJOH1PXFSBOEBVUPTUFQ
sequence settings
t1SPUFDUJPO0WFSWPMUBHFPWFSUFNQFSBUVSF
surge limit, soft start, brown out and short
circuit protection current limit fold back.
The Sorensen DHP Series provides models ranging
in output power from 5 kW to 20 kW in a single
chassis. Programmable output voltages range
from 5V to 50 VDC, delivering up to 3,000
amperes. This family has two operational modes,
constant-voltage and constant-current.
The DHP Series uses control technology
permits up to nine (9) steps per sequence
with a maximum sequence duration of up
to 27.75 hours.
This family has standard analog and a variety
of combinations of IEEE-488.2, RS-232 and/or
isolated analog input control interface options.
5–50 V
133–3000 A
208400480
858.458.0223
sales@ProgrammablePower.com
71
DHP Series : Product Specications
Common
Front Panel ControlsKeypad to select/adjust voltage, current and power with non-volatile memories to store commonly used parameters
Remote Control/Monitor (Rear Panel)On/off control via contact closure, 6-120 VDC, 12-240 VAC, TTL or CMOS switch, output voltage and current monitor,
Remote SenseThe maximum line drop is 3% per line or 1V for 5-15V units, 3V for all others. Line drop subtracts from the maximum available
Internal Programming9 memories are on-board for auto-step programming. Each step can be 1 second to 99,999 seconds or 27.78 hours long
ProtectionOver temperature, brown out, turn on surge limit, slow start, overvoltage (OVP resettable without recycling power)
Displays and IndicatorsBack lit LCD alphanumeric display and LEDs
RegulatoryCE mark (LVD and EMC directive), Certied to UL/cUL 61010 (Up to 10kW output), EMC is to IEC 61326-1
Input
Voltage Ranges190-253 VAC, 47-63 Hz (Standard)
PhasesThree phase, 3-wire plus ground, Delta or Wye input may be used (Wye does not require the neutral connection)
Power Factor0.72 min.
Output
Stability±0.05% maximum rating per 8 hours after a 30 minute warm-up time at xed line, load and temperature
Line RegulationFor input voltage variation over the AC input voltage range, with constant rated load.
Load RegulationFor 0-100% load variation, with constant nominal line voltage.
Transient Response2 ms to steady state output voltage (within 2% of Vmax) for 30% step load change
Efciency80% minimum at full load
Temperature Coefcient0.02%/°C of rated output voltage; 0.03%/°C of rated output current. Change in output per °C change in ambient
Environmental
Operating Temperature0°C to 50°C (no derating)
Storage Temperature-20°C to 70°C
PhysicalCase 1Case 2
DimensionsWidth: 19” (482 mm)
Weight80 lbs. ( 55 kg )160 lbs. ( 73 kg )
Shipping Weight 120 lbs. ( 73 kg )200 lbs. ( 91 kg )
Remote Digital Control
Programming ResolutionVoltage: 0.3% of full scale;
Programming AccuracyVoltage: 0.1% + 0.3% of maximum output voltage
Readback AccuracyVoltage: 0.1% + 0.3% of full scale output voltage;
Soft CalibrationCalibration via front panel without removing chassis covers
SoftwareLabVIEW® driver for M9D, programs can be downloaded at no cost at : www.programmablepower.com
* After 30 minutes operation with xed line, load and temperature
*Note: For high power 40V models and models above 50V see SG Series.
Specications subject to change.
Ripple
(rms)
TypicalCase16 kW to 20 kW*
Output DCRipple
(rms)
Typical
CaseVoltageAmpsVoltageAmps
J3 Connector
1Remote Output Enable14TTL/CMOS On/Off Control
2Remote Return for Pins 1 and 1415Remote Voltage Programming Input
3Remote OVP Programming Input16Remote Current Programming Input
4Voltage Return for Pins 9, 15 or 2117Fault State
5Remote On/Off18Shutdown Fault
6Circuit Common19Output Voltage Monitor
7Current Monitor Output20Voltage Return for Pins 9, 15 or 21
8Local Voltage Control Monitor21Voltage Control Resistance
9Remote Voltage Programming Input22Current Control Resistance
10Remote Current Programming Input23Current Return for Pins 10, 16 or 22
11Local Current Control Monitor24Circuit Common
12Remote Sense –25Current Return for Pins 10, 16 or 22
13Remote Sense +
858.458.0223
sales@ProgrammablePower.com
73
DHP Series : Diagram
Case ICase II
Dimensions in inches (millimeters)
Top View
Front View
Rear View
Top View
Front View
Rear View
74
www.ProgrammablePower.com
DHP Series
Model Number Description
5–20 kW
DHP30
Series
Voltage
Options and Accessories
M1360-440 VAC, 47-63 Hz, three phase, 3-wire plus ground, Delta or Wye may be used
M2432-528 VAC, 47-63 Hz, three phase, 3-wire plus ground, Delta or Wye may be used
M8Internal RS-232 remote serial interface
M9DInternal IEEE-488.2 interface
M10Both IEEE-488.2 and RS-232
M11RS-232 and isolated analog programming
M12IEEE-488.2 and isolated analog programming
M14IEEE-488.2, RS-232 and isolated analog programming
M51Isolated analog programming Input Voltage Options. This isolation allows users to control power supplies not connected to
a common ground. In addition, in systems with high ambient noise or with large ground loop currents the control ground
can be isolated from the power ground eliminating problems.
Software
LabVIEW® driver for M9D, programs can be downloaded at no cost at : http://www.elgar.com/products/DHP/DHP_Downloads.htm