Measurements are not limited to just classic analog and digital signals. Please find further detailed information to
expand your system in the chapter “Components”.
A/D card
High performance portable all-in-one instrument
Flexible mixture of isolated and differential analog inputs
Function panels for digital I/O, counters, sensor supply …
Up to 7 PCI slots for A/D and other cards (1394, ARINC, 1553…)
Fully battery powered (optional)
Choose from three models
Add your choice of signal conditioning,
A/D board(s) and software to complete these systems
DEWE-2600 series
Input specificationsDEWE-2600DEWE-2601DEWE-2602
Slots for DAQ or PAD modules16-16
MDAQ input channels-
Available panel space2 x 2U1 x 4U and 1x 4.5 U2 x 2U
Main system
Total PCI-slots2 full / 2 half length4 full / 3 half length2 full / 2 half length
Hard disk1 TB removable HDD
Data throughputTyp. 80 MB/s
Power supply95 to 260 VAC
Display15” TFT display, 1280 x 800 pixel
Processor
RAM3 GB
Ethernet2 x 1 Gbit LAN
USB interfaces4
RS-232 interface1
Storage driveInternal DVD +/-RW burner
Operating systemMicrosoft® WINDOWS® 7
Dimensions (W x D x H)417 x 246 x 303 mm (16.4 x 9.7 x 11.9 in.)
WeightTyp. 14 kg (31 lb.)
Environmental specifications
Operating temperature0 to +50 °C, down to -20 °C with prewarmed unit
Storage temperature-20 to +70 °C
Humidity10 to 80 % non cond., 5 to 95 % rel. humidity
Vibration
Shock
1)
Please find current specifications in the latest price list
2)
Depends on the system configuration. Examples:
• DEWE-2601 with 6x DEWE-ORION-1616-500 could stream 80 MB/s to the harddisk
• DEWE-2600 with 4 x DEWE-ORION-1624-200 + 2x DEWE-CAM01 could store 70 MB/s
3)
Tested with Solid State Disk
1)
3)
3)
Up to 80 (BNC connectors)
Up to 64 (DSUB connectors)
2)
Intel® Core™ i5/i7
EN 60068-2-6, EN 60721-3-2 class 2M2
EN 60068-2-27
Up to 32
All-In-One
Needed to complete the system
DEWE-ORION “A/D Boards” offer simultaneous sampled
analog inputs, synchronous digital I/Os, high-performance
counters and high-speed CAN interfaces. DAQP- or MDAQ
signal amplifiers and software are needed as well.
DEWESoftDAQP/MDAQ
Options to expand the system
Add further “Interface Cards” like ARINC-429, 1553, PCM
telemetry, FireWire and analog output or special “Sensors”
like synchronized Video, industrial encoders (RIE-360) or
GPS.
ARINCVIDEOVGPS
www.dewetron.com/dewe-2600
Software Components Signal Conditioning Front-ends Instruments Dedicated Instruments DEWE2
99
DEWE-2600
Configuration Guide DEWE-2600
Most flexible model, prepared for DAQP isolated analog input amplifier modules. DAQP conditioners offer highest
bandwidth, great accuracy, different input ranges and integrated filters. Besides the single channel modularity – a
module easily can be changed by the user at any time – the main advantage of these modules is the high galvanic
isolation which ensures safe measurements, high quality results and make them almost indestructible. See chapter
“Signal Conditioning” for details.
Function panels
Standard panel for DEWE-2600-CA2Analog input - DAQ modules
Options
0.5U-CLAMP-DC-POWER-8
0.5 U
±15 V power supply and digital status
2 U
Combustion analyzer input
1.5 U
1.5U-TC-PANEL-32
2 U
lines for PNA-CLAMP-150-DC
0.5U-AMPFLEX-POWER-8
0.5 U
Power supply for PNA-A100
current clamps
0.5U-AOUT-BNC-2
0.5 U
1U-AOUT-BNC-4
1 U
Thermocouple inputs via 4 MPAD-TH-8
1.5U-ORION-DIO-PANEL-1
1.5 U
1U-AOUT-BNC-8
1 U
Analog output
Counter input with digital input
Configuration Guide DEWE-2601
High channel count version, for direct sensor input via differential MDAQ analog input amplifiers. MDAQ modules are
available in cost efficient and space saving 8-channel blocks. See chapter “Signal Conditioning” for details.
MDAQ panels
Options
1.5U-ORION-DIO-PANEL-1
1.5 U
2 U
2 U
Analog input - MDAQ modules
1.5U-TC-PANEL-32
1.5 U
Thermocouple inputs via 4 MPAD-TH-8
4 U4.5 U
0.5 U
Limited use
(no 1.5 U MDAQ panel
in this area)
1.5 U
Counter input with digital input
0.5U-CLAMP-DC-POWER-8
0.5 U
±15 V power supply and digital status
lines for PNA-CLAMP-150-DC
0.5U-AMPFLEX-POWER-8
0.5 U
Power supply for PNA-A100
current clamps
0.5U-AOUT-BNC-2
0.5 U
1U-AOUT-BNC-4
1 U
1U-AOUT-BNC-8
1 U
Analog output
100
www.dewetron.com
All-In-One
Configuration Guide DEWE-2602
This version combines slots for isolated DAQP modules and positions for differential MDAQ blocks. Thus it enables
you configuring a cost optimized system that needs isolated inputs, e.g. high voltage signals, and a number of differential inputs, e.g. accelerometers.
OptionsMDAQ panels
Analog input - DAQ modules
1.5U-ORION-DIO-PANEL-1
1.5 U
2 U
2 U
Analog input - MDAQ modules
1.5 U
Thermocouple inputs via 4 MPAD-TH-8
1.5U-TC-PANEL-32
2 U
1.5 U
Counter input with digital input
0.5U-CLAMP-DC-POWER-8
0.5 U
±15 V power supply and digital status
lines for PNA-CLAMP-150-DC
0.5U-AMPFLEX-POWER-8
0.5 U
Power supply for PNA-A100
current clamps
0.5U-AOUT-BNC-2
0.5 U
1U-AOUT-BNC-4
1 U
1U-AOUT-BNC-8
1 U
Analog output
Typical Configurations
DEWE-2600
16 isolated DAQP modules
4 MPAD modules
(16 tc “T” and 16 tc “J” inputs)
8 counters + 16 extra digital input
DEWE-2602
16 isolated DAQP modules
16 differential analog MDAQ inputs
8 counters + 16 extra digital inputs
DEWE-2601
80 differential analog MDAQ inputs
Software Components Signal Conditioning Front-ends Instruments Dedicated Instruments DEWE2
101
DEWE-2600
Channel Expansion
Signal conditioning for slow signals is added by connecting EPAD2 series modules to the systems EPAD interface.
For expanding the number of dynamic channels there are three choices:
Analog cable
boards are installed into the basic
instrument and external signal conditioning, e.g. DAQ modules in a
DEWE-30 chassis, is connected by
means of an analog signal cable.
: Several instruments are connected via Ethernet. Each unit requires
an ORION-SYNC option. For short distances a sync cable is used if the units
are far from each other a sync interface
System options and upgrades for DEWE-2600 series
OptionsDescription
DISP-15-TOUCHTouchscreen for 15“ display
2600-FIREWIREPCI Express FireWire® interface for the DEWE-2600
BAT-CHARGER-1Desktop battery charger for 1 battery, incl. external AC adaptor
BAT-CHARGER-4Desktop battery charger for 4 batteries, incl. external AC adaptor
PS-BAT-REMOTE-ON
UpgradesDescription
HDD-1000-SSD-128
HDD-REM-1000Spare removable hard disk, 1 TB
2600-SYSTEM-SSD-64Additional internal SSD 64 GB for Windows and DEWESoft, the removable hard disk remains
18 .. 24 VDC non-isolated input, incl. external AC power supply DEWE-POW-24-350,
3 slots for hot-swappable batteries, 3 batteries for appr. 3 hours operation included,
for DC operation always add DEWE-DCDC-24-300-ISO
External DC/DC converter with isolation,
9 to 36 VDC input range, Lemo EGJ.3B.302, incl. 2 m cable to banana jacks,
24 VDC output, 300 W, Lemo EGG.2B.302 socket
Special add-on for the battery power supply, one extra connection with a wake-up signal is needed to the
power supply input of the unit,
allows to automatically turn on the instrument when the ignition of the car is turned on, also turns off the
instrument when the car is turned off
Upgrade to 128 GB ash disk (replaces 1 TB hard disk),
max. data throughput 40 MB/s
2600-SYSTEM-SSD-64
Additional internal Solid State Disk
2600-PS-BAT
Optional battery power supply
This option turns your DEWE-2600 into a fully battery powered instrument. The hotswappable batteries guarantee continuous operation without an external power
source. The instrument provides 3 slots for BAT-95WH batteries and can be operated for up to ~2 hours with 3 batteries installed. Since this time depends a lot on
the system configuration a DEWESoft plugin shows the battery status directly in the
software. Also alarm conditions can be set and the battery parameters can be displayed as additional measurement channels. Operating temperature is limited to
0 .. 45° C when batteries are charged.
HDD-REM-600
Spare removable harddisk, 600 GB
for classified work
2600-CSMK1
Car seat mounting kit
DEWE-DCDC-24-300-ISO
Isolated DC power supply, needed
to operate units with 2600-PS-BAT
option from DC
: Additional A/D
102
PCI expansion: A PCI-HOST card
is installed into the basic instrument and external signal conditioning, e.g. DAQ modules in a
DEWE-50 chassis, is connected by
means of a PCI cable.
DEWE-NET
like DEWE-CLOCK is used.
www.dewetron.com
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.