Atec DET20C User Manual

arth/Ground Resistance & Leakage Current Clamp Testers
E
DET10C, DET20C
Earth/Ground Resistance & Leakage Current Clamp Testers
n
Easy, fast clamp-on operation – No rods or cables necessary
n
Measures ground resistance from 0.025 to 1550
n
Measures ground leakage current from
0.2mA to 35A
n
Auto ranging with high and low alarms
n
Automatic self calibration
n
Extensive data storage and USB data download for later analysis (DET20C)
DET10C DET20C
DESCRIPTION
The Megger models DET10C and 20C measure earth/ground resistance and current flow using clamp-on technology. The instruments induce a test current into the system without the need to disturb existing connections. Either unit is a useful addition to the more traditional methods of earth/ground resistance testing that may require disconnection and the use of stakes or ground rods. Simply clamp around the conductor or stake/rod and measure the resistance to ground fast and accurately.
The DET10C and 20C can also be used to measur earth/ground resistance in multiple loop installations without disconnecting the earth or ground. This allows the user to perform the test quickly and easily in total safety, with the added convenience of having a single point of measurement to read the earth/ground resistance.
Each instrument also provides a true RMS current measurement reading to better indicate potential measurement problems and provide a useful overview of the dynamics of the general earth/gr
ound system.
e
The units are rugged, compact and have configurable audible alarms. They also feature auto shutdown (which is also configurable), data storage and self calibration on power-up, and are supplied with a calibration loop – all contained in a rugged carry case. The DET20C also comes with a USB interface cable and is compatible with Megger Download Manager Software (included) allowing further analysis and storage of data.
APPLICATION
The DET10C and 20C have a variety of applications including:
n
Use to measur loops ar
n
Use on multi-grounded systems without disconnecting the gr
n
Use to measure leakage current flowing to ground or circulating in gr
n
Use on cell towers, RF transmitters and telecommunications sites.
n
Use to inspect and verify lightning protection systems.
n
Use on a variety of consumer installations, including pools, spas, etc.
n
Measure shield leakage current to ground for shield continuity checks
ound pads and buildings.
ound rod/stake under test.
esistance and continuity of gr
e r
ound systems.
ounding
EATURES AND BENEFITS
F
n
Easy and fast clamp-on operation. No need for cables or auxiliary rods/stakes.
n
Large LCD display screen that can be read in bright
unlight.
s
n
easures ground resistance from 0.025to 1550.
M
n
Direct reading of continuity and ground loop resistance.
n
Measures ground leakage or phase current from
0.2mA to 35A.
n
arge jaw opening to accommodate a variety of
L
onductors.
c
n
Indication of high noise content that may affect readings.
n
Lightweight...only 750g (1.65lbs), yet exceptionally rugged for regular field use.
n
Hold function for difficult to reach installations.
n
Auto-off to save on battery power.
n
Configure high and low alarms with audible indication for fast field checks.
n
On board storage of test results (up to 8180 records).
n
Calibration check loop to insure proper operation.
n
Rugged, yet lightweight storage case contains complete testing kit.
n
USB interface for download of test data for later analysis (DET20C).
DET10C DET20C
arth/Ground Resistance & Leakage Current Clamp Testers
E
LECTRICAL SPECIFICATIONS
E
Ground Resistance Resolution Accuracy
Range
2
0.025 - 0.25 0.002 ± 1.5% ± 0.05
0.25 - 9.999 0.02 ± 1.5% ± 0.1 10 - 99.99 0.04 ± 2.0% ± 0.3
100 - 199.9 0.4 ± 3.0% ± 1.0
200 - 400 2 ± 5.0% ± 5 400 - 600 5 ± 10% ± 10
600 - 1550 20 ± 20%
1
Loop resistance non-inductive, external field <50 A/m, external electrical field <1 V/m, conductor centred in jaws.
2
Resistance measurement frequency 1.667KHz
Alarm Type Range Resolution
High Alarm 0 - 1550 1
Low Alarm 0 - 1550 1
Leakage Current Resolution Accuracy
3
Range
0.200 – 1.000 mA 0.001 mA ± 2.0% ± 0.05 mA
1.00 – 10.00 mA 0.01 mA ± 2.0% ± 0.03 mA
10.0 – 100.0 mA 0.1 mA ± 2.0% ± 0.3 mA 100 – 1000 mA 1 mA ± 2.0% ± 3 mA
0.20 – 35 A 0.01 A ± 2.0% ± 0.03 A
3
Auto range, 50/60Hz, true RMS to crest factor <3.5
1
The DET20C instrument is shown being used to test a pole ground.
GENERAL SPECIFICATION
Conductor size ..................................35mm Ø approx
Battery type ......................................9V IEC 6 LR61 alkaline
Display type ......................................4 digits 9999 counts LCD
Range selection ................................Automatic within function
Overload indication..........................OL
Power consumption..........................40 mA
Battery life ........................................3000 measurements approx
Auto power down ............................5 minutes approx
Sampling time ..................................0.5 seconds
Operating temperature ....................0 to 50º C
Storage temperature..........................-20º C to 60º C
Operating humidity ..........................Less than 85% RH
Storage humidity ..............................Less than 75% RH
Dimensions........................................276 L X 100 W X 47 H (mm)
................................................
eight
W
Data logging capacity DET10C ........116 records
Data logging capacity DET20C ........8180 records
750g (1.65lbs)