Atec DDX9121B User Manual

DDX 9121B
Modular Partial Discharge (PD) & Radio Interference Voltage (RIV) Detector
The DDX 9121b is the latest in the DDX family for partial discharge & radio interference voltage testing. With the DDX 9121b you can setup, control, test, monitor and generate test reports from a single computer.
Its modular design makes the DDX9121b flexible for any application. From single measuring input to simultaneous 9 measuring inputs. From traditional partial discharge according IEC60270 to RIV measurement or PD under DC. From pass/fail test to advance phase resolution time analysis. The DDX9121b includes all you need, and have all you want.
The DDX 9121B comprises 1 to 9 rack-mounted unit(s) communicating with a remote PC (not included), which handles the display of PD information using the DDX 9121b/SWR data acquisition and remote control software. The software displays test results, generates test reports, and provides a means to calibrate the system.
Digital filters allow the measurement frequency range to be at any range into the measuring band to suppress frequency dependent noise. In addition gating possibilities allow blanking out stationary interferences.
The reports can then be printed out from the software or displayed as a web page. With help of the software the user can also export the results for use in a spreadsheet. Software also provides bitmaps for inclusion in other reports.
FEATURES
User defined measuring band. Modular design, 1 to 9 detectors, easily upgradable. Embedded switch with four PD inputs per detector. Simultaneous RIV and PD reading. PD patterns like φHigh resolution spectrum analyzer with oscilloscope. Data acquisition and test report generation. AC and DC measuring modes
-q-n
( phase, magnitude, occurrence)
BENEFITS
Reduce your ground noise –The built in frequency
spectrum analysis and selectable frequency band let you optimize your setup in seconds.
Optimize your investment if your needs change. Unit can
be easily upgraded (RIV, 4 inputs switch, simultaneous PD readings, PD on DC…)
Reduce your training time –The Windows based software
makes the use of the device easier than ever. Operators can start using the device in minutes.
Straightforward replacement –replacement is as simple as
removing the obsolete PD detector and measuring quadripole and installing the DDX9121b.
PD interpretation – The phase resolved analysis and
recording capabilities allow for future data analysis.
Easy to integrate into test systems – Its compact design
standard BNC measuring cables and remote control capabilities make it ideal for an integrated PD test system together with an AC power supply.
APPLICATIONS
Testing of:
Power and distribution transformers Instrument Transformers Rotating Machines Power Capacitors Switchgears Surge Arrestors Research & Development
Haefely has a policy of continuous product improvement. Therefore we reserve the right to change design and specification without notice. LL_DDX9121b-1_1311_SG_1.doc – 1/6
USER ORIENTATED INTERFACE
The user interface has been designed to make PD readings easy. All options are grouped by categories, and the scope window shows all test related information. Even specific colours have been selected to reduce the strain on the user’s eyes during long term testing.
Indications about the detector status, selected frequency band, input channel, PD level, Test voltage, and frequency are grouped in the scope window and can be displayed at any time.
Detector settings are displayed next to the scope window by clicking the settings button, all options are grouped by category to make the configuration of the device easier than ever.
MODULAR DESIGN
for normal partial discharge test on one phase test objects the DDX9121-1 is equipped with one measuring input (DDX9121b-1).
For distribution transformers, the DDX9121b-MUX option (released by software code) add an embedded manual
switch with “ALL” option. With this new feature the
transformer is tested as a single phase test object, and switch is only used to locate the phase if PD level is above the limit.
For power transformers, several detectors (up to 9) can be combined and connected to a single computer providing simultaneous PD readings. Complete measuring system can be controlled from a laptop or built into a measuring desk.
REAL TIME SIMULTANEOUS MEASUREMENTS
The DDX®9121b multi-detector PD system provides simultaneous PD level and phase resolved displays of the PD activity at any given moment during the test. A user can use this information to characterize and possibly locate the origin of discharge sources.
A chart recorder provides a hard copy of partial discharge level versus voltage and testing time for each channel in one customized graph. Any time during the test the partial discharge levels can be monitored and after the completion of the test, customized test reports for the multiple channels can be generated which automatically populate with snap-shots from notable events.
Haefely has a policy of continuous product improvement. Therefore we reserve the right to change design and specification without notice. LL_DDX9121b-1_1311_SG_1.doc – 2/6
0
20
40
60
80
100
120
1 10 100 1000 1000 0
Frequency (kHz)
f
1
f
2
0
20
40
60
80
100
120
1 10 100 10 00 1000 0
Partial discharge FFT
RF broadcast FFT Tyristor pulse FFT
Optimized measuring band
f(khz)
SELECTABLE MEASURING BAND
A wide band detector measures and displays the composite of all the signals and interference present within its bandwidth. Any PD activity will be difficult to differentiate from the noise floor. However, there could be a number of areas in the frequency spectrum where PD signals is at a much higher level than the unwanted interference. Defining a measuring band within these optimized areas will result in a higher measuring sensitivity and therefore a lower ground noise level.
The IEC 60270 defines some limits in regards to the measuring band as following.
30kHz < f1 < 100kHz
f2 < 500kHz
100kHz<f <400kHz
EASY TO CONFIGURE
The DDX9121b measuring system is based on passive coupling impedances without batteries. In addition the wide range of the input voltage (140 V) makes the device connection easier than ever.
Just connect the coupling impedance (AKV9310) to your coupling capacitor, plug the DDX9121 to the net and connect through a normal or fiber optic (optional) LAN cable to the computer. Connect the included twin BNC cable between the DDX9121b and the impedance and start measuring PD.
SIMULTANEOUS PD AND RIV READINGS (OPTIONAL)
The DDX 9121b measures RIV according to ANSI and NEMA 107-1987, therefore the replacement of outdated RIV measuring instruments is straight forward without differences in measurement results.
Both RIV voltage (mV, According to NEMA 107-1987) and Partial discharge (pC, according IEC 60270) measurements are done simultaneously, therefore both are performed in a single test without overstressing the test object. In addition, real time comparison between PD level and RIV is possible.
PD UNDER DC (OPTIONAL)
The DDX9121b is equipped with a frequency spectrum analyzer, where the operator can easily select the optimized measuring band based on the measured ground noise.
Haefely has a policy of continuous product improvement. Therefore we reserve the right to change design and specification without notice. LL_DDX9121b-1_1311_SG_1.doc – 3/6
While measuring PD on DC test voltage, an accurate recording of each PD event is of maximum importance, as the accepting/rejecting value will take into consideration not only the magnitude of the pulses, also the number of pulses during the test duration. The DDX9121b is a trusty device while doing this particular test.
V(kV)
PD(pC)
Inception
Voltage
PD trigger level
Extintion
Voltage
PD Pattern
Noise Pattern
DATA ACQUISITION & ANALYSIS
The advanced data acquisition and analysis software allows a wide variety of possibilities such as recording PD pulses of each and every test voltage cycle and analyzing them both in the temporal and phase domain.
A chart recorder provides a hard copy of partial discharge level versus voltage and testing time for each channel in one customized graph. At any time during the test the partial discharge levels can be monitored and after the completion of the test, customized test reports for the multiple channels can be generated which automatically populate with snap-shots from notable events.
Chart Recorder with graphs PD vs. voltage and time
With the pattern acquisition and analysis module, several two- and three-dimensional PD pulse patterns of all the monitored channels (when equipped with a multiplexer) can be displayed and recorded. Snaps shots of the 3D patterns can be saved into a windows gallery for further uses like customized test report generation or to export them as image files.
Data filters and time-sliced views further permits a detailed look at the PD pattern as deep as every cycle of the applied test voltage and in certain cases, helps separate and identify noise interferences.
INCEPTION AND EXTINTION PD TEST
IEC 60270, on paragraph 8.3.1 describes the inception/extinction PD test. Generally the test is performed by increasing the voltage until the PD level reaches a trigger level, and then voltage is decreased until the PD level goes below the trigger level. Voltage levels are recorded at those two moments as Inception and extinction voltages.
The DDX9121b can show graphically the results of this particular test, and provide the inception and extinction voltages.
DATA EXPORT AND REPORTING
The reports are saved as HTML files containing graphs and charts. In addition all data can be exported as comma separated values(CSV) format for further analysis or highly customized test reports in other programs like MS Excel
Haefely has a policy of continuous product improvement. Therefore we reserve the right to change design and specification without notice. LL_DDX9121b-1_1311_SG_1.doc – 4/6
Simultaneous PD inputs
1 1 3 3 4 4 6 6 8 8 Non-simultaneous PD inputs Option DDX9121b/MUX
Opt 4 Opt 3 Opt
12
Opt
11
Opt
16
Opt
15
Opt
24
Opt
23
Opt
32
Opt
31
Simultaneous RIV inputs
Not 1 Not 3 Not 4 Not 6 Not 8 Non simultaneous RIV inputs
Option DDX9121b/MUX
Not
Opt 3 Not
Opt
11
Not
Opt
15
No
Opt
23
Not
Opt
31
PD on DC Option DDX9121b/DC
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Phase resolve analysis
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Spectrum analyzer and scope
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Selectable measuring band
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
DDX9121b/MUX
DDX9121b/FO
software key to enable the embedded non simultaneous 4 inputs
Fiber optic adaptor to connect the DDX9121b and the computer DDX9121b/DC
Software key to enable PD measurement under DC
LAPTOP
DESK WITH MINIRACK AND PCI COMPUTER
Laptop with DDX9121b software preinstalled and configured. Windows 7 in English included.
Desk with minirack including PCI computer, screen and mouse. DDX9121b and windows 7 pre-installed MINIRACK
Rack on wheels for multi-detector configurations, rack can be located into the test room and connected to the computer through fiber optics
Key code
Key code
STANDARD CONFIGURATIONS
Opt -> Option
Other configurations than the ones below in regards to number of detectors or options are available upon request.
RIV calibrator included in the device picture is requested but has to be purchased separately
OPTIONS
COMPUTERS AND RACKS
Haefely has a policy of continuous product improvement. Therefore we reserve the right to change design and specification without notice. LL_DDX9121b-1_1311_SG_1.doc – 5/6
PD Measuring
Input Impedance
50
PD System Bandwidth
30 kHz … 1.5 MHz (-6dB) (with internal analog filter)
10 kHz … 1.5 MHz (-6dB) (without internal analog filter)
Filter Center Frequency
Freely selectable (32 kHz … 1.498
MHz)
Filter Bandwidth
4 kHz / 4.5 kHz / 9 kHz
10 … 100 kHz, in 10 kHz steps
100 … 500 kHz, in 50 kHz steps
600 kHz … 1 MHz, in 100 kHz steps
Sensitivity
< 0.1 pC (directly at AKV 9310/T quadripole input)
Input Atten. Range
0 dB / 20 dB / 40 dB
Linearity Error
< 5 % (1 … 100 % FSR)
Pulse Phase Resolution
0.35°
Voltage Measurement
Input Voltage Range
0.14 … 140 VAC (RMS)
-200 … -0.2 / +0.2 … +200 VDC
Frequency Range
15 … 400 Hz
Input Impedance
1.7 M / 11 pF
Linearity Error
< 1 % (0.1 … 100 % FSR)
Synchronization
Voltage or Mains input
Synchronization Accur.
< 5° Environmental
Operating temperature
0°C … +45°C
Storage temperature
-20°C ... +60°C
Relative Humidity
5% … 80%, non-condensing
RIV Measurement System
Frequency Range
850 … 1150 kHz
IF Filter Bandwidth
4.5 kHz and 9 kHz
Image Rejection
> 55 dB
Stop Band Attenuation
> 70 dB @ 7.5 kHz
> 60 dB @ 10 kHz
Linearity Error
2 dB @ 10 Hz … 1 kHz PRF, 1/10 … 10x calibration level
Quasi-Peak Detector Response
According to NEMA 107, ANSI C63.2-1996
Power Supply & Mechanical
Voltage
90 … 264 VAC
Frequency
50 / 60Hz
Dimensions (WxDxH)
483 mm x 306 mm x 89 mm
Weight
6.2 kg
EMC
Compliant to EMC directive 2004/108/EC (EN 61326-1)
Safety
Low voltage directive 2006/95/EC (IEC 60010-1)
Vibration
MIL-STD-810G Table 514.6C-II, Category common carrier
Applicable Standards
IEC-60060 Parts 1&2
ICEA T-24-380
IEC-60270
ASTM D1868-93
IEC-885-2 and 885-3
ANSI C57.113
IEEE Std. 4, 1995
ANSI C57.124-91
ANSI C63.2-1996
NEMA 107
CALIBRATORS
KAL 9520 High precision PD calibrator
High precision partial discharge calibrator touch screen controlled with a very wide, continuously variable output pC range
9216 hand held battery PD calibrator
Small battery powered PD calibrator. Pulses outputs ranges are 10, 100, 1000 and 10’000 pC
KAL 9530 RIV calibrator
RIV calibrator (KAL 9530) including a signal generator, RIV calibration set, clamp and a switching.
MEASURING IMPEDANCES
AKV 9310 passive universal coupling impedance
Compact impedance fully passive with enhanced sensitivity. AKV 9330 Capacitors optimized coupling impedance
Active measuring impedance optimized for PD testing of power capacitor as per IEC 60270. It is rated for 300 amperes.
COUPLING CAPACITORS
9230 coupling capacitors
Consist of a high voltage unit mounted on a mobile (with wheels) base frame and includes a suitable top electrode and a coupling impedance.
Europe, Asia, South & Central America, Australia
Haefely Test AG Birsstrasse 300 4052 Basel Switzerland + 41 61 373 4111 + 41 61 373 4912 sales@tettex.com
China (Sales & Service Office)
Haefely Test AG – Beijing Office
8-1-602, Fortune Street
No. 67, Chaoyang Road, Chaoyang District
Beijing, 100025
P. R. China
+ 86 10 8578 8099
+ 86 10 8578 9908
sales@haefely.com.cn
North America
Hipotronics Inc.
1650 Route 22
PO Box 414
Brewster, NY 10509
USA
+ 1 845 279 3644 + 1 845 279 2467
sales@hipotronics.com
TECHNICAL SPECIFICATIONS
ACCESSORIES FOR PD TESTING
www.haefely.com
Haefely has a policy of continuous product improvement. Therefore we reserve the right to change design and specification without notice. LL_DDX9121b-1_1311_SG_1.doc – 6/6
Loading...