The APS 3000 Series frequency and voltage converters are economically priced and offer top of the line performance.
The series consists of seven 3 phase output instruments
ranging in size from 3 kVA to 90 kVA. The converters allow
the user to duplicate a utility grid of either 50 or 60 hertz
for export product testing or operation of imported
for applications such as the testing of military/avionics
equipment or for the operation of 400 hertz electronics that
are onboard an aircraft or a military vessel. The adjustable
frequency band of 45 to 500 Hertz in conjunction with the
dual line to neutral voltage ranges of 0-150 volts or 0-300
volts provides full capabilities for testing and operating
electronics worldwide.
Setup and operation of the APS 3000 Series is
exceptionally easy. The simple front panel layout allows
users to continuously vary voltage and frequency or
to select preset standard frequency settings. Individual
meter displays provide digital readouts for frequency,
voltage and current while a digital multimeter displays
power or power factor.
The APS 3000 Series converters are a simple and cost
effective solution for all of your AC power conversion needs!
Worldwide
Supplier
of Power
Conversion
Equipment
Toll Free 1-866-517-8400 www.adaptivepower.com
TM
Key Features & Specifications for the APS 3000 Series
• Output Power: 3 kVA to 90 kVA
• Output Frequency: 45-500 Hz
• Output Voltage: Dual range, 150/260 V or 300/520 V,
3 phase
• Isolated Output, THD: < 1%
• Input Requirements: 220, 240, 380, 415, 480 VAC
± 10%, 3 phase, 47-63 Hz (3kVA and 6kVA, 230VAC ± 15%, 1 phase)
• Intuitive Front Panel Controls: Frequency and Voltage
• Easy to Read LED Displays: Frequency, Voltage, Current,
Power and Power Factor
• Memory Locations: Can save three desired settings
of any voltage, frequency and current limit covered in the output parameters
MODEL 3003 3006 3009 3015 3030 3060 3090
INPUT SPECIFICATIONS
Phase 1Ø/2W + ground 3Ø/3W + ground
Voltage 230V±15% 220, 240, 380, 415, 480V±10%
Frequency 47-63Hz
OUTPUT SPECIFICATIONS
Power rating
Total Power 3kVA 6kVA 9kVA 15kVA 30kVA 60kVA 90kVA
Per Phase 1kVA 2kVA 3kVA 5kVA 10kVA 20kVA 30kVA
Max Arms per Ø @ 0-150 V 8.4 A 16.8 A 25.2 A 42.0 A 84.0 A 168.0 A 252.0 A
Max Arms per Ø @ 0-300 V 4.2 A 8.4 A 12.6 A 21.0 A 42.0 A 84.0 A 126.0 A
Phase 3Ø/5W
Voltage
Line to Neutral 0-150V/0-300V Selectable
Line to Line 0-260V/0-520V Selectable
Resolution 0.1V
Accuracy ±(1%+0.2V)
Frequency
Range 45-500Hz
Resolution 0.1Hz at 45-99.9Hz, 1Hz at 100-500Hz
Accuracy ±0.2%
Harmonic Distortion 1%(Resistance Load)
Crest Factor 3 to 1
Load Regulation ±0.5%
Protection Over Current, Short Circuit, Over Temperature
Efficiency 85% (at full load)
Operating Temperature 32°-104°F, (0°-40°C), 80% Relative Humidity
Altitude below 6500 feet
DISPLAYS AND CONTROLS
4 Digital LED meters Frequency, Voltage, Current, Power or Power Factor (simultaneously)
PLC Remote Interface P1, P2, P3, and Output On/Off
Memory 3 Programmable Memory Locations for Voltage, Frequency and Current
Calibration Front Panel Calibration
Interface (optional) GPIB, or RS-232
Auto voltage adjust Enable for improved voltage regulation within ±0.1V
MECHANICAL SPECIFICATIONS
3kVA 6kVA 9kVA 15kVA 30kVA 60kVA 90kVA
Dimensions (HxDxW) Inches 29x26x17 29x26x17 32x36x24 32x36x24 38x36x24 55x36x24 71x36x48
Weights (Kg/lbs) 105/230 120/265 220/485 290/640 460/1010 760/1675 1200/2640
©2003 ADAPTIVE POWER SYSTEMS, Irvine, CA, U.S.A. Subject to change without notice.
Cooling fans
Output curcuit breaker
Output connections
Input curcuit breaker
801 Hailey Street Ardmore, OK 73401
Direct: 949-752-8400 • Fax: 949-756-0838 Toll Free: 1-866-517-8400 www.adaptivepower.com
TM
APS3000-9/06
Instrument Specifications
Input connections
Casters