Atec AE-Techron-7796HC User Manual

2507 Warren Street, Elkhart, IN 46516 USA | 574.295- 9495 | www.AETechron.com
7796HC SPECIF ICATION SHEET
The AE Techron 7796HC amplifier is a DC-enabled unit optimized for high­power, continuous operation into very­low-impedance loads. A single 7796HC has an output capability of up to 200 amperes peak. If more current is needed, up to four amplifiers can be combined in parallel and operate as a single system.
The 7796HC can operate in either voltage or current mode. It provides very low noise and fast slew rates, and can safely drive a wide range of resistive, inductive loads.
Typical use includes as a power source for EMC testing in applications that require both continuous AC or DC signals and significant short term (burst) signals (DO-160, MIL 461, and MIL 704).

Performance

Frequency Response:

DC – 30 kHz +0.1 – 0.5 dB

Phase Response:

+/- 8.3 degrees (10 Hz – 10 kHz)

Unit to Unit Phase Error:

+/- 0.1 degrees at 60 Hz

Maximum Continuous Output Power:

2499 watts RMS

Output offset current:

Less than 10 milliamperes DC

Features

40 mSec pulses of up to 157 amperes peak into a 0.25-ohm load.
System output of over 600 amperes maximum are possible with multiple, interconnected am plif iers .
Frequency bandwidth of DC to 75 kHz at rated power, DC to 150 kHz at reduced power.
Rugged chassis for stand-alone or rack mounted operation. No additional power supplies are required.
Protection circuitry protects the AE Techron 7796HC from input overloads, improper output connection (including shorted and improper loads), over-temperature, over-current, and supply voltages that are too high or low.
Shipped ready to operate from 208-volt (±10%) three-phase AC mains. NOTE: 400 VAC version not available.
7796HC
Current over time at 100 Hz
120.00
100.00
80.00
60.00
40.00
Amps RMS
20.00
0.00 1 16 31 46 61
Minutes
0.25 Ohm
0.5 Ohm
1 Ohm
2 Ohms
7796HC Datasheet Information subject to change. 5/4//11
AC Specifications
PEAK OUTPUT RMS OUTPUT
Ohms
Volts
Amps
Volts
Amps
Volts
Amps
Volts
Amps
Volts
Amps
Watts
1
56
56
55
55
55
55
39
39
39
39
1512
40mSec Pulse,
20% Duty Cycle
2 79 39 79 39 79 39 56 28 56 28 1540
0.5 53 106 52 104 50 100 37 74 35 71 2499
0.25 40 157 38 152 35 139 27 107 25 98 2432
5 Minute,
100% Duty Cycle
1 Hour,
100% Duty Cycle
5 Minute,
100% Duty Cycle
1 Hour,
100% Duty Cycle
Input Characteristics

Balanced with Ground:

Three terminal barrier block connector 20k ohm differential

Unbalanced:

BNC connector, 10k ohm single ended
Gain: Voltage Mode: 20 volts/volt Current Mode: 20 amperes/volt

Residual Noise:

DC – 30 kHz: Less than 75 microvolts DC – 100 kHz: Less than 1 millivolt

Slew Rate:

41 volts per microsecond

Display, Control, Status

Front Panel LED Displays indicate:

Ready, Standby and Fault conditions in the output stage

LCD Display:

Lists type of fault condition and gives suggested corrective action

Soft Touch Switches for:

Run (Enable), Stop, Reset

User Configurable:

LCD display can be configured for up to four simultaneous displays reporting one, two or all four of the following: Voltage Peak, Voltage RMS, Current Peak, and Current RMS

Physical Characteristic s

Chassis:

All aluminum construction designed for stand-alone or rack-mounted operation with black chassis; the amplifier occupies five EIA 19-inch-wide rack units

Weight:

103 lbs. (46.7 kg)

AC Power:

Three-phase, 208 VAC ±10%, 47-60 Hz, 30A AC service. NOTE: 400 VAC version not available.

Operating Temperature:

10°C to 50°C (50°F to 122°F), Maximum Output Power de-rated above 30°C (86°F).)

Humidity:

70% or less, non-condensing
7796HC Datasheet Information subject to change. 5/4//11
Loading...