2507 Warren Street, Elkhart, IN 46516 USA | 574.295- 9495 | www.AETechron.com
7796HC SPECIF ICATION SHEET
The AE Techron 7796HC amplifier is a
DC-enabled unit optimized for highpower, continuous operation into verylow-impedance loads. A single
7796HC has an output capability of up
to 200 amperes peak. If more current
is needed, up to four amplifiers can be
combined in parallel and operate as a
single system.
The 7796HC can operate in either
voltage or current mode. It provides
very low noise and fast slew rates, and
can safely drive a wide range of
resistive, inductive loads.
Typical use includes as a power
source for EMC testing in applications
that require both continuous AC or DC
signals and significant short term
(burst) signals (DO-160, MIL 461, and
MIL 704).
Performance
Frequency Response:
DC – 30 kHz +0.1 – 0.5 dB
Phase Response:
+/- 8.3 degrees (10 Hz – 10 kHz)
Unit to Unit Phase Error:
+/- 0.1 degrees at 60 Hz
Maximum Continuous Output
Power:
2499 watts RMS
Output offset current:
Less than 10 milliamperes DC
Features
• 40 mSec pulses of up to 157 amperes peak into a 0.25-ohm
load.
• System output of over 600 amperes maximum are possible with
multiple, interconnected am plif iers .
• Frequency bandwidth of DC to 75 kHz at rated power, DC to
150 kHz at reduced power.
• Rugged chassis for stand-alone or rack mounted operation. No
additional power supplies are required.
• Protection circuitry protects the AE Techron 7796HC from input
overloads, improper output connection (including shorted and
improper loads), over-temperature, over-current, and supply
voltages that are too high or low.
• Shipped ready to operate from 208-volt (±10%) three-phase AC
mains. NOTE: 400 VAC version not available.
7796HC
Current over time at 100 Hz
120.00
100.00
80.00
60.00
40.00
Amps RMS
20.00
0.00
1 16 31 46 61
Minutes
0.25 Ohm
0.5 Ohm
1 Ohm
2 Ohms
7796HC Datasheet Information subject to change. 5/4//11
PEAK OUTPUT RMS OUTPUT
40mSec Pulse,
20% Duty Cycle
2 79 39 79 39 79 39 56 28 56 28 1540
0.5 53 106 52 104 50 100 37 74 35 71 2499
0.25 40 157 38 152 35 139 27 107 25 98 2432
5 Minute,
100% Duty Cycle
1 Hour,
100% Duty Cycle
5 Minute,
100% Duty Cycle
1 Hour,
100% Duty Cycle
Input Characteristics
Balanced with Ground:
Three terminal barrier block connector
20k ohm differential
Unbalanced:
BNC connector, 10k ohm single ended
Gain:
Voltage Mode: 20 volts/volt
Current Mode: 20 amperes/volt
Residual Noise:
DC – 30 kHz: Less than 75 microvolts
DC – 100 kHz: Less than 1 millivolt
Slew Rate:
41 volts per microsecond
Display, Control, Status
Front Panel
LED Displays indicate:
Ready, Standby and Fault conditions
in the output stage
LCD Display:
Lists type of fault condition and gives
suggested corrective action
Soft Touch Switches for:
Run (Enable), Stop, Reset
User Configurable:
LCD display can be configured for up
to four simultaneous displays reporting
one, two or all four of the following:
Voltage Peak, Voltage RMS, Current
Peak, and Current RMS
Physical Characteristic s
Chassis:
All aluminum construction designed for
stand-alone or rack-mounted operation
with black chassis; the amplifier
occupies five EIA 19-inch-wide rack
units
Weight:
103 lbs. (46.7 kg)
AC Power:
Three-phase, 208 VAC ±10%, 47-60 Hz, 30A AC service.
NOTE: 400 VAC version not available.
Operating Temperature:
10°C to 50°C (50°F to 122°F), Maximum Output Power de-rated
above 30°C (86°F).)
Humidity:
70% or less, non-condensing
7796HC Datasheet Information subject to change. 5/4//11