1000V Digital/Analog Megohmmeter Models 1050 & 1060 (pdf) Rev. 05 01/05
Technical Assistance (800) 343-1391 www.aemc.com 2 of 9
FUNCTION MODEL MODEL
1050 1060
50V (0.002MΩ to 200GΩ) ✓✓
100V (0.004MΩ to 400GΩ) ✓✓
250V (0.01MΩ to 1TΩ) ✓✓
500V (0.02MΩ to 2TΩ) ✓✓
1000V (40kΩ to 4TΩ) ✓✓
Voltage Test/Safety Check (600VAC/DC) ✓✓
Guard Terminal ✓✓
Continuity (40Ω) @200mA ✓✓
Resistance (400kΩ) ✓✓
Lead Compensation ✓✓
Backlight ✓✓
Timer (1–59 minutes) ✓✓
Digital Dual Display ✓✓
Analog Bargraph ✓✓
Auto-Off ✓✓
Continuity Buzzer ✓✓
Continuity Buzzer Disable ✓✓
Voltage Detection (>25V) ✓✓
Safety Test Inhibitor ✓✓
Automatic Discharge ✓✓
Rechargable NiMH Battery – ✓
AC Supply 85-256V/50/60Hz – ✓
Battery Powered – ✓
Battery Capacity (%) Indication ✓✓
Auto-Off Disable ✓✓
Automatic DAR/PI ✓✓
Smooth Function ✓✓
Memory Storage (128kB) – ✓
Report Printout on Serial Printer – ✓
RS-232 Communication – ✓
Features
• True Megohmmeter
®
• Test voltage combinations of 50V, 100V, 250V,
500V and 1000V
• Insulation measurements to 4000GΩ (4TΩ)
• Direct measurement of DAR and PI values
• Direct measurement of sample Capacitance
• Display of test voltage and run time
• Programmable test run times and PI times
• Smooth and Alarm functions
• Automatic test inhibition (if live sample >25V)
• Automatic discharge after use with voltage display
• Large dual display with time, voltage and measurement
• Bright blue electroluminescent backlight
• Battery powered
• Auto power-down when not in use
• Remote operation with optional test probe
• Rugged dual wall field case with detachable lead/
accessory pouch
• EN 61010-1, 600V Cat. III, EN 61557
• CE Mark
Model 1060 includes these
additional features:
• AC rechargeable NiMH batteries – run while recharging
• RS-232 interface for direct printing of results (serial output)
• 128kB memory to store measurements in specific files
• Remote operation of megohmmeter through PC
• Includes DataView
®
software for data storage, real-time
display, analysis and report generation
Applications
• Test insulation on cables, transformers, motors, insulators
and wiring installations
• High resistance or absorption tests
• Spot reading tests
• Timed resistance measurements
• Dielectric Absorption Ratio (DAR) and
Polarization Index (PI) tests
• Low insulation test range for testing old or flooded
installations
• Motor insulation resistance measurements
• Continuity checks and low resistance measurements
• Computer controlled production line testing
• Predictive maintenance by storing results in PC for
trend analysis
Model 1060 checking insulation resistance between windings on a
three-phase motor.