■ Output distortion less than 0.3%, and peak
repetitive current over 2.5 times for rms current
(6404, 6408)
■ High accuracy measurement for RMS voltage,
RMS current, true power, frequency, power
factor, and current crest factor
■ Built-in power factor correction circuit provides
input power factor over 0.98 to meet
IEC regulations
■ Programmable current limit
■ Built-in output isolation relays
■ EEPROM storage for user defined voltage and
frequency combinatio for instant recall
at anytime
■ Optional GPIB, RS-232, and Analog
Programming Interface
■ Over voltage, under voltage, over power,
over current, over temperature, and
short circuit protection
■ Temperature controlled fan speed
■ Self-test at power-on
■ User-definable power-on state
RS-232GPIBAPG
ThE COST EFFECTIvE PROGRAMMAblE AC POwER SOuRCES
U
P
S
U
P
S
AC
DC
The 6400 Series AC Power Source supplies very clean output with typical output distortion less
than 0.3% THD. The output is transformer isolated (6404 & 6408) providing an
exceptionally low total harmonic distortion without sacrificing efficiency.
Remote sense connections are provided for superb output regulation to
compensate for load line losses while keeping the output at a precise
level regardless of output load condition.
6460
6463
6490
Th e 640 0 Se rie s incor por ate s in put power fa cto r
correction circuitry resulting in high efficiency
an d lo we r in put li ne curr en t. Th e 6400
Series emplo ys advance d DSP circu itry
(6404 & 6408) or 16-bi t meas ure ment
ci rcu it to prov ide pre cis e hig h-spe ed
measu re me nt of the outpu t for true
RMS voltage, true RMS cur rent, true power,
frequency, power factor, and curr ent crest
fac tor. These out put mea surements can be
displayed on the
large, easy to read, front panel readout. The 6400 Series
are easy to operate using the front panel keypad, (6404 &
6408) with 9-user programmable output voltage, frequ ency, and
current limit combinations for quick and consistent testing. An optional controller
can be added for GPIB, RS232 or analog programming for completely automated testing applications.
The interface is a plug-in card that can change the 6400 from a manual unit
to a computer-controlled system AC power source.
With the small 5.25 inches height packaged (6404 & 6408), and lightweight, the model 6400 is perfectly suitable for bench top applications where space is at a
premium. The easy to use and easy to read front panel control/readout system makes setup and quick measurements simple. The front panel receptacles can
be used for most line cord plugs without adapters. Rear panel terminals are also provided for hard-wired connections. A temperature controlled fan speed
circuit is used to keep fan noise reduced when operating on the bench or in a quiet lab environment. The 6400 Series can also be easily rack-mounted without
special mounting kits or modifications.
6408
6415
6404
6420
6430
The wide output voltage range of 0-300 VAC (0-500VAC for Model 6460) can be selected for either 0-150 VAC or 0-300 VAC, or set to auto-ranging output
voltage. The 45-1000 Hz output frequency range provides excellent flexibility in a small compact unit with a great performance / cost ratio. The programmable
current limit adds to the flexibility while reducing current flow potential for non-destructive testing easily.
The 6400 Series provides a self-diagnostic routine, easy to set programmable output over voltage limit, input line under voltage protection, output
overpower, over current, over temperature, and fan failure protection.
The 6400 Series offers quality, reliability, and flexibility for the most demanding applications in production tests, R&D, and QA verification.
APPlICATIONS
IEC standard
compliance testing
PC & monitor
testing
Servo motor,
synchro motor testing
AC ballast
testing
Transformers
testing
Relays, switches
testing
TRIACs, SCRs & passive
components testing
Product safety
testing
UPS function &
environmental
testing
Power supply input
function & environmental
testing
Air conditioner
testing
Avionics testing of
military & aircraft
Breakers,
fuses testing
Lamp circuit
testing
PANEl DESCRIPTION
12
354
1. Measurement item indicators
2. Select measurement items of current,
power factor, or crest factor
3. Set output voltage, frequency, and current limit
4. Data setting and function keys
5. Rotary knob for adjusting output setting
6. Power switch
7. Status indicators
8. Universal output socket
6 78
9
9. Output enable and disable
SPECIFICATIONS
Model640464086415 6420
Output / Phase1111
Output Ratings
Power / Phase 375VA800VA1500VA2000VA
Voltage
Range / Phase150V/300V/Auto
Accuracy0.2% F.S. for freq. ≦ 200Hz, 0.4% F.S. for freq. > 200Hz0.2% + 0.2% of F.S.
Resolution0.1V0.1V 0.1V 0.1V
Distortiontypical. 0.3% for freq. ≦ 200Hz, 0.8% for freq.>200Hz0.5% for (45-500Hz), 1% for (> 500-1kHz)
Line Regulation 0.1%0.1%0.1%0.1%
Load Regulation 0.1%0.1%0.1%0.1%
Temp. Coecient0.02% per ˚C
Others
Efficiency75% typical80% typical80% typical80% typical
ProtectionUVP, OVP, OCP, OPP, OTP, Short
Safety & EMCCE (Include LVD and EMC Requirement)
Dimension (H x W x D)133.35 x 482.6 x 471.4 mm / 5.25 x 19 x 18.56 inch221.5 x 425 x 567 mm / 8.72 x 16.73 x 22.32 inch
Weight18 kg / 39.65 lbs23 kg / 50.66 lbs23 kg / 50.66 lbs27 kg / 59.47 lbs
peak
7A/3.5A ≦100Hz
5.5A/12.75A >100Hz
14.92A/7.47A ≦ 100Hz
7.47A/5.87A >100Hz
90-132V (6408-1),
180-250V (6408-2)
12A max.(6408-1),
6A max. (6408-2)
45A/22.5A ≦ 100Hz (45-100Hz)
37.5A/18.75A (>100-1kHz)
190-250V, 1Ø190-250V, 1Ø
12A max.15A max.
60A/30A (45-100Hz)
50A/25A (>100-1kHz)
SPECIFICATIONS
Model643064606463 6490
Output / Phase11 (parallel or series)1 or 3 selectable1 or 3 selectable
Output Ratings
Power / Phase3000VA6000VA2000VA3000VA
Voltage
Range / Phase150V/300V/Auto
150V/300V(parallel),
300V/500V(series)
150V/300V150V/300V
Accuracy0.2% + 0.2% of F.S.0.2% + 0.2% of F.S.0.2% + 0.2% of F.S.0.2% + 0.2% of F.S.
Resolution0.1V0.1V0.1V 0.1V
Distortion
0.5% for (45-500Hz),
1% for (> 500-1KHz)
1%1%1%
Line Regulation0.1%0.1%0.1% 0.1%
Load Regulation0.1%0.2%(series), 0.8% (parallel)0.2%(3 phases), 0.8% (1 phase) 0.2%(3 phases), 0.8% (1 phase)
Temp. Coecient0.02% per ˚C0.02% per ˚C 0.02% per ˚C0.02% per ˚C
Max. current -rms / Phase30A/15A 60A/30A/15A (150V/300V/500V)20A/10A (150V/300V)30A/15A ( 150V/300V)
Peak Current/
Input Ratings
Voltage Range190-250V, 1Ø190-250V, 3Ø190-250V, 3Ø190-250V, 3Ø
Frequency Range47-63Hz47-63Hz47-63Hz47-63Hz
Current 23A max.23A max./phase15A max./phase23A max./phase
Power Factor 0.98 min.0.98 min. under full load0.97 min. under full load0.98 min. under full load
Measurement
Voltage / Phase