Atec 6000L User Manual

AC Power Systems
Test All Products Operating from AC Power
nn Voltage ranges up to 400 V RMS, L-N
Standard 135/270 V or optional ranges to 400 V
nn Single- and Three Phase Models
3 kVA to 30 kVA products re­configurable for single- or three-phase operation (MODE option)
nn High Peak Current Capability
Up to 9:1 crest factor for driving high peak current loads
nn High Frequency Range
Capable of output frequencies up to 5000 Hz on some models

L-Series

Full Capability
AC Sources
for Product Test
Controller Choices:
nn Simulate Non-Standard AC
Line Conditions
Line disturbance simulation
nn Monitor Load Parameters
Without Additional Instru­mentation
Full measurement capability on programmable controllers
High Frequency PWM Design
nn Rack Space Savings up
to 50 %
Small front panel size and weight for precision power
nn High Efficiency
Generates less heat and consumes less input power
Now you can test any product that operates from AC power with the most compact, versatile power source in the test industry. The L-Series’ small size provides more power per inch than most other AC supplies. Highly effi­cient, these products dissipate less heat than previous genera­tion systems and allow up to an additional 10 % output power. With a programmable controller, L-Series models provide the most comprehensive set of program­mable functions in the industry. Automatic remote calibration and comprehensive self-tests simplify maintainability.
All L Series units are com­pletely self-contained. Control is through an embedded oscillator, factory configured to your specific requirements. Output parameters are controlled via the front panel or the IEEE-488 bus. Bus pro-
gramming, standard with -P,
-PT and HGA controllers, allows programming and measure­ment function readback com­patible with a number of other standards including VXI, MXI and RS232 via recommended translators. To simplify pro­gramming, the standard unit supports both Abbreviated Plain English programming and an ATLAS-based control language.
For avionics applications, any 3-phase model can be config­ured with 26 V and 5 V auxiliary outputs. (AX option)
The L Series is ideal for ap­plications where small size, low heat dissipation and light weight are important. These include DC power supply testing, pro­duction test, quality assurance verification, engineering and ATE.
Our broad range of models lets you choose the right power level for your application
Model Power Phase2Current in 135 V range Cur/phase Size Weight
at 35° C
1
A rms A peak3A peak43ø mode (H x W x D)
751L 833 VA 1 6.2 55.6 60 n/a 1501L 1667 VA 1 12.3 55.6 60 n/a 5.25” x 19” x 23” 85 lb 1503L 1667 VA 3 4.1 9.3 10 4.1 133 x 483 x 584 mm 38.3 Kg 2001L 2000 VA 1 14.8 55.6 60 n/a 2750L 3000 VA 1 or 3 22.2 83.3 90 7.4 10.5” x 19” x 23” 175 lb 4500L 5000 VA 1 or 3 37 83.3 90 12.3 267 x 483 x 584 mm 97.2 Kg 6000L 6000 VA 1 or 3 44.4 157.4 170 14.8 9000L 10000 VA 1 or 3 74 166.7 180 24.7 21” x 19” x 23” 350 lb 12000L 12000 VA 1 or 3 90 314.8 340 30.0 533 x 483 x 584 mm 158 Kg 13500L 15000 VA 1 or 3 111.2 250.0 270 37.0 31.5” x 19” x 23” 525 lb 18000L 18000 VA 1 or 3 133.2 472.0 510 44.4 800 x 483 x 584 mm 238 Kg
Notes: 1 Derate power by 10% for operation at 50° C ambient or when using the -UP option 3 Repetitive peak current capability
2 1 or 3 phase systems are factory configured unless the “MODE” option is specified 4 Non repetitive peak inrush current
The L-Series offers the ultimate in flexibility. Select the power level best suited to your requirements. Then
select the controller that provides the functions important to you. Complete your selection by choosing from
the L-Series’ comprehensive list of options, and you have a truly custom solution at an “off-the-shelf” price.
All L-Series Models Conform to These Specifications:
Output Voltage Ranges
Standard: 0-135 V, L-N
0-270 V, L-N
-HV Option: 0-156 V, L-N
0-312 V, L-N
-LV Option: 0-67.5 V, L-N
0-135 V, L-N
-EHV Option: 0-200 V, L-N
0-400 V, L-N
Total Harmonic Distortion
45 Hz to 2 kHz: 1 percent To 5 kHz: 2 percent 50/60 Hz: 0.5 percent typical
Line Input
Models 751L, 1501L, 1503L, 2001L:
115 V or 230 V single phase 47 Hz to 440 Hz
Models 2750L, 4500L, 6000L, 9000L, 12000L, 13500L, 18000L:
187 V - 252 V, L-L, 3 phase (342 V - 456 V, L-L, 3 phase with
-UP option, except 6000L, 12000L and 18000L)
2750L: 1 or 3 phase input 187 -
252 V
Output Frequency
See V-F derating for 17 Hz to 45 Hz performance
Models 751L, 1501L, 1503L, 2001L, 2750L-3, 4500L-3 and 6000L-3:
17 Hz to 5 kHz
Models 2750L-1, 4500L-1, 9000L and 13500L:
17 Hz to 2 kHz
Models 6000L-1, 12000L and 18000L:
17 Hz to 440 Hz
All models with -PT controller:
17 Hz to 550 Hz except 6000L, 12000L and 18000L
AC Noise Level
160 mV rms typical
Connectors
nn Input provided on rear terminal
block
nn Output provided on rear
terminal block (Remote sense
Protection
nn Overcurrent nn Overpower nn Short circuit nn Overtemperature nn Current limit trip standard with
Rating Curves
mating connectors are provided)
programmable units. All units have adjustable current limit.
Loading...
+ 4 hidden pages