PORTABLE DC
HIPOTS
PHENIX Technologies offers a line of conservatively
designed and ruggedly built portable DC Hipots for use in
testing electrical switchgear, cables, motors, generators, and
protective equipment. DC testing is popular because the
equipment is more compact and lighter in weight than
comparable AC equipment and is also generally less expensive.
The DC Hipots offered by PHENIX Technologies are
suitable for lab or field use and are especially helpful when it is
needed to determine the adequacy of newly installed insulation
or to determine when corrective steps are neces-
sary to return equipment to a safe operating
condition. The results of DC tests will help predict
the useful life of insulation Establishing a consis-
tent maintenance testing program reduces failures
and extends equipment life.
l
Continuously adjustable output
l
Negative output, positive ground
Guard circuit for stray leakage current
l
bypass
Three range voltmeters
l
l
Zero start interlock
CONTROL POWER ON switch with
l
indicator
HV ON/OFF pushbuttons with indicators
l
l
External interlock provision
Surge and transient protection
l
l
Rugged impact/corosion resistant roto-
molded cases with carrying handles and
cable storage
l
6-foot input cord (three wire)
20-foot test leads (3) with clips and boots
l
l
25-foot interconnect cable (4120-5, 4160-2)
Model 470-5
Model 4160-2
l
Adjustable overcurrent trip on selected
modelsplease inquire
l
Grounding stick
Other output voltages
l
l
Discharge Stick
Digital meters
l
l
Output and return lead lengths can be
specified
*Based on our commitment to continual research and development PHENIX
Technologies reserves the right to update product specifications without notice!
EXPERIENCE...QUALITY...RELIABILITY
40104
Control Panel Layout
1
2
3
4
5
6
8
7
VOLTAGE
60
100
70
80
90
MODEL 4100-5
CAL
100kV
50kV
25kV
CAL
X1K
X100
X10
AC INPUT
EXT.INTLK.
20
19
18
F1 F2 F3
MAIN POWER
ON
OFF
!
RETURN GND GUARD
WARNING!
DONOT TOUCH OR REMOVE RETURN CABLES
DURINGTESTING. FAILURE TO HEED THIS
WARNINGCAN CAUSE LETHAL SHOCK
PHENIX
TECHNOLOGIES
Accident,Maryland, USA
DC HIPOT TEST SET
R
!
RANGE (kV)
50
25
100
MULTIPLIER
X100
X10
X1
HIGH VOLTAGE
CAUTION
HIGH VOLTAGE
CURRENT
X1K
VOLTAGECONTROL
50
40
30
20
10
0
ZEROSTART
1314151617
Dimensions/Weights*
MODEL
Dimensions
Weight*
MODEL
Control Module
HV Module
430-5
21” W x 17” D x 14” H
(533mm) x (432mm) (355mm)
53 lbs. (24kg)
4120-5
21” W x 17” D x 14” H
(533mm) (432mm) (355mm)
33 lbs. (15kg)
17.5” W x 12” D x 22” H
(440mm) (305mm) (560mm)
111 lbs. (50kg)
470-5
21” W x 17” D x 14” H
(533mm) x (432mm) (355mm)
80 lbs. (36kg)
4160-2
21” W x 17” D x 14” H
(535mm) (435mm) (355mm)
33 lbs. (15kg)
18” W x 12.75” D x 28” H
(460mm) (325mm) (710mm)
150 lbs. (68kg)
*Note: for 220 VAC, add 10 lbs. (4.5kg) to 470-5, 4100-5, 4120-5 and 4160-2 controls; 4 lbs. (1.8kg) to 430-5.
4100-5
22.5” W x 20 ” D x 16.5”H
(572mm) (508mm) (420mm)
106 lbs. (48kg)
1. AC power cord
2. Output lead
3. Return terminal
9
4. Ground terminal
5. Guard terminal
6. Voltmeter range selector
7. Currentmeter range
selector
8. Three-range voltmeter
10
9. Voltmeter calibration
potentiometers
11
10. Currentmeter calibration
potentiometers
11. Four-range currentmeter
12
12. Output voltage control
13. High Voltage OFF
14. High Voltage ON
15. Backup fuse
16. Main fuse
17. Control power indicator
18. Control power switch
19. Main fuse
20. External interlock
The PHENIX Technologies Product Line
●
AC Dielectric Test Sets
●
Resonant Test Sets
●
DC Hipots and Insulation Test Sets
●
Automatic Insulating Material Testers (Dl49)
●
Liquid Dielectric Test Sets
●
Megohmmeters
●
Vacuum/Oil Interrupter Testers
●
Bucket Truck Testers
●
High-Frequency Cable Aging Test Sets
●
Heat Cycling Test Sets
●
Rubber Goods—Protective Equipment Testers
●
Core Loss Testers
Your local representative is
7/02
●
AC, DC and AC/DC Motor Test Sets
●
Transformer Test Systems
●
Computerized Circuit Breaker Test Sets
●
Computerized Recloser Test Sets
●
DC Power Supplies
●
High Voltage DC Cable Thumpers
●
High Voltage Terminations
●
High Power Column-Type Variable Transformers
●
High Power Thoma-Type Variable Transformers
●
Voltage and Current Stabilizers
116 Industrial Drive
Accident, MD 21520 USA
Tel: 301-746-8118
Fax: 301-895-5570
http://www.phenixtech.com