Atec 320AMX User Manual

Page 1
Models 320AMX-320AMXT
2,000VA
20-5,000 Hz
0-338V
4
0-600V
4
0-338VL-N / 585VL-L
4
L-N
L-L
1, 2, or 3Ø – Linear AC Power Source
Standard Features:
Advanced Linear Ampliers Provide Very Low Voltage Distortion, no Switching Noise, Fast Voltage and Current Slew Rates, Exceptionally Low Output Impedance and High Peak Current Capability
1, 2, or 3 Phase Output Form selectable from front panel or bus command
Precision Voltage Programming – 0.05% with Continuous Self-Calibration (CSC) engaged
True-RMS Metering of Volts, Amps, and Power
GPIB (IEEE-488.2) or RS-232 Interface
Waveform Library – Arbitrary Waveform Generator
Up to 99 Programs with Associated Transients for Static and Dynamic Test Applications
UPC Studio Software Suite
Available Options:
T-versions include external transformer assembly for higher voltage ranges
Programmable Output Impedance
Harmonic Analysis and Waveform Synthesis
Peak Inrush Capture and Waveform Analysis (Available on models with UPC3 controller)
UPC Test Manager Software
Model 320AMX
As a member of Pacic Power’s AMX-Series popular family of high performance Linear AC Power Sources, the 320AMX oers the same low output voltage noise and distortion, ease of installation, and high AC waveform delity as found in all of Pacic Power’s Linear AC Power Sources. Control and operational features provide a high degree of versatility and ease of use for applications ranging from simple, manually controlled frequency conversion to harmonic testing and sophisticated programmable transient simulation.
AC TEST POWER
All 320AMX and 320AMXT models are equipped with a powerful micro-controller with the ability to operate as a fully integrated test system. This enables a variety of power conditions and transients to be applied to the device under test while metering and analyzing all output performance parameters. For higher power requirements, refer to the AMX & ASX series catalog.
FREQUENCY/ VOLTAGE CONVERSION
The 320AMX is an excellent source of stable AC Voltage over the frequency range of 20 to 5,000 Hz (Direct Coupled Range) or 45 to 5,000 Hz (Transformer Coupled AMXT models) when using the high-end UPC-32 controller. Also available in 1,200 Hz maximum output frequency when using UPC3 or Manual controller. The output frequency is quartz-crystal stabilized. Output voltages up to 270V mode are available on the 320AMX model and up to 600V 320AMXT model.
PHASE CONVERSION
With the ability to provide either single or two phase output, the 320AMX is a good choice to convert three-phase line voltage into precisely controlled split (two-phase) or single­phase output power.
in split phase mode and 234V
L-L
in three phase mode on the
L-L
in three phase
L-L
UPC Manager Software Suite
Master the Power of the Wave!
UPC SERIES CONTROLLER
Three controller models are available in both manual and programmable control version. All controllers provide manual operation from the front panel. Programmable
UPC Manager Software gives you the tools necessary to quickly and easily operate your AC Power Source. With our graphical interface control all areas of your AC Power Source testing with simple presets, user prompts, test sequences, test plans and custom reports.
Controllers may be operated from the front panel or from a remote interface via RS 232 or GPIB.
The Leader in AC Power Technology
An early pioneer in the development solid-state power conversion equipment, Pacic Power Source continues to develop, manufacture, and market both linear and high-performance PWM AC Power Sources. Pacic Power Source’s reputation as a market and technology leader is best demonstrated by its continuing investments in both research and development and world-wide customer support. With corporate owned oces in the United States, Germany, the United Kingdom, and China, local personalized support is always available.
THE POWER OF EXPERTISE
FREQUENCY CONVERSION R & D MANUFACTURINGAEROSPACE MILITARY CUSTOM
Page 2
320AMX-320AMXT
Output Ratings
320AMX
Output Voltage3
Rated Power (VA)
2,000
1
Coupling Mode
Direct 1Ø/2Ø
Form
2
V
Max
RMS
(L-N/L-L)
135/270 135/234
320AMXT
Output Voltage3
1
Rated Power (VA)
2,000
Coupling Mode
Direct
Transformer 1.5:1
Transformer 2.0:1
Transformer 2.5:1
NOTES:
1. Rated output power is based on a combination of nominal output voltage, rated current and load power factor. Values stated represent the maximum capabilities of a given model (maximum power in split phase (Form2) direct coupled mode is 1.3 kVA). Consult factory for assistance in determining specic unit capabilities as they might apply to your application.
2. Unit is operable as single phase with dual range capability or 3 phase. Output voltage range and 1/2/3 conversions are selected by front panel or bus commands.
3. Vmax is output voltage with nominal input and full rated load applied.
4. Available current will vary with output voltage and power factor. Current shown is per phase.
AMX Power Source Specications (PF = 1.0, V
Output Frequency
Full Power
20-5,000 Hz Direct Coupled
45-5,000 Hz Transformer Coupled
Line Regulation
0.1% max for a ±10% line
change
2
Form
1Ø/2Ø
1Ø/2Ø
1Ø/2Ø
1Ø/2Ø
V
Max
RMS
(L-N/L-L)
135/270 135/234
202/404 202/350
270/540 270/468
338/600 338/585
out
> 25% F.S.)
Load Regulation
Direct Coupled Ranges:
0.25% 20 to 2,000 Hz.
0.50% 2,000 to 5,000 Hz.
Improves to less than 0.03% with external sense and CSC enabled.
Transformer Coupled Ranges:
Improve to < 0.1% with external sense and CSC enabled.
Input Power Requirements (47-63 Hz)
Input Voltage
Input Current
Recommended
Input service
208VAC 3ØΔ
±10%
11A
RMS
20A
220VAC 3ØΔ
±10%
10A
RMS
20A
Thermal and Power Factor Rating Curves
Rated Continuous Load Current as a Function of Ambient Temperature and Power Factor and Output Voltage at Nominal Input Line.
Current
(A
RMS
18/6
6/Ø
Current
(A
RMS
18/6
6/Ø
12/4 4/Ø
9/3 3/Ø
7.2/2.4
2.4/Ø
1:5:1 2% 2:0:1 4% 2:5:1 5%
240VAC 3ØΔ
4
)
4
)
±10%
9A
20A
RMS
Frequency
Range
20-5000
Frequency
Range
20-5000
45-5000
45-5000
45-5000
47-63Hz
47-63Hz
Output Distortion
0.1% THD
AVG
0.25% THD
220/380VAC
±10%
6A
RMS
10A
Input
Power
Input
Power
45 to 1,000 Hz
20 to 5,000 Hz
AVG
Unit Height
In/mm/U
8.75/222/5U
Unit Height
In/mm/U
320AMX
8.75/222/5U
Transformer Module
5.25/133/3U
Ripple and Noise
-72dB
240/416VAC
±10%
5A
RMS
10A
Unit Weight
(Lbs/Kg)
125/56.8
Unit Weight
(Lbs/Kg)
320AMX
125 /56.8
Transformer
Module
125 /56.8
Response Time
5 µsec typ. For
step load change.
Small signal
bandwidth = 5 Hz
to 40 KHz
277/480VAC
±10%
(Cost Option)
5A
RMS
10A
THERMAL RATING -AC CURRENT RMS Short tem overloads to 150% of rated current are permitted. Operating time before thermal shutdown or circuit breaker trip varies from seconds to several minutes depending upon line
and temperature conditions.
OUTPUT VOLTAGE-AC VOLTS RMS
Short term overloads to 150% are permitted. Operating time before thermal shutdown or circuit breaker trip varies from seconds to several minutes depending upon line and tempera­ture conditions.
Page 3
Total Control, Metering, and Analysis of AC Power- Simple, Intuitive Operation
The UPC Controller is a highly versatile one, two, or three
phase oscillator/signal generator designed to control any of Pacic Power’s AC Power Sources. Three controller models, UPC-3M, UPC-3, or UPC-32 are oered. To use the full 5KHz power bandwidth of the 320AMX or 320AMXT, the UPC-32
controller is required.
Using the front panel keyboard and display, all controller
models provide for selection of power source output mode, cou­pling, voltage, and frequency. Selecting the correct UPC controller for a given application varies with your test requirement, desired features, and price.
Both the UPC-3 and UPC-32 Controllers are available with
either RS-232 or GPIB remote interface. Commands are structured in accordance with SCPI (Standard Commands for Programmable Instruments).
4 x 16 Character LCD
Program Edit and Function Key
320AMX-320AMXT
Parameter Control
Ouput Control, Slew, and enable Keys
Features
Output Modes
Waveform Library
Transient Functions
Program Library
Programmable Current Limit
Programmable Current Protect
Programmable Phase Angle
CSC (Continuous Self-Calibration)
Remote Interface
Std Opt
Waveform Synthesis/Analysis
Prog. Output Impedance
Inrush Peak Detect
DRM Link-Synchronization
Line Synchronization
Analog Auxilary Input
AM-Amplitude Modulation
Sync Outputs Zero Crossing
Transient Trigger
Transient Pedestal
Output Clock
Waveform Synthesis
(/HAS Option)
Waveform Analysis
(/HAS Option)
Controller Models
UPC-3M
1Ø, 2Ø, & 3Ø 1Ø, 2Ø, & 3Ø
Sine
NO
NO
YES
YES
NO
YES
NONE NONE
NO
NO
NO
NO
NO NO
UPC-3 UPC-32
1Ø, 2Ø, & 3Ø
Sine +
21 Editable
YES, 50 Steps
99 Programs
Sine +
15 Editable
YES, 99 Steps
99 Programs
YES YES
YES
YES, 0 to 359°
YES, 0 to 359°
YES
RS-232
GPIB
RS-232
OPTIONAL OPTIONAL
OPTIONALOPTIONAL
OPTIONAL
NO
OPTIONAL
OPTIONAL
YES
YES
GPIB
NO
External Inputs/Outputs
Each phase is algebraically summed with UPC waveform and amplied 25X to the direct coupled output. ±10Vpk (20Vpk-pk). One input per phase. ZIN = 600 Ω
±10 Vdc (20Vpk-pk) modulates the output voltage ±100% One input per phase. Z
Positive Zero Crossing (0°) of Phase A analog output
Pulse at the start of a transient event. (UPC-32 only)
TTL True when a transient is in progress
UPC-3, TTL level pulse rate varies with output frequency UPC-32, TTL level 1024 x output frequency
= 600 Ω
IN
Waveform Control
Creates waveform by entering magnitude as % of fundamental and specied phase angle for 2nd through the 51st harmonic
Reports waveform harmonic content and phase angle relative to the fundamental for the 2nd through the 51st harmonic as Total, Odd, and Even harmonic distortion
Frequency
Voltage
Phase Angle
ØB and ØC relative to ØA
Current Limit
Voltmeter
True V
each
RMS
phase
Ammeter
True A
and
RMS
Apk each phase
Power Meter
True Watts and Volt-Amps each phase
Power Factor
Ratio : kW
/kVA
mtr
Crest Factor
Ratio: Apk/A
Freq. Display
Output Control Specications
UPC-3M/UPC-3
20-1,200Hz
Range
Resolution
Accuracy
Range (l-n)
Resolution
0.5% of full scale (CSC Disabled)
Accuracy
±0. 05% referenced to Internal Meter (CSC Enabled)
Range
Resolution
Accuracy
Range
Resolution
Accuracy
(1) Full power output limited to 1=5,000 Hz in AMX models
15.00 -150Hz, ± 0.5° ±0. 5°
15.00 - 300 Hz, ± 1°
15.00 - 600 Hz, ± 2°
15.00 - 1,200Hz, ± 3°
1Ø = 0 -60A
±3% F.S.
4 Signicant Digits
±0.01% of full scale
0 - 150/375
0.1V/ 0.5V
0 - 359°
± 1°
RMS
0.05% F.S.
UPC-32
20-5,000Hz
3Ø = 0 - 20
±1% F.S.
Output Metering
UPC-32
L-L
50-500Hz, ± 0.25% of rdg. ± 0.1% F.S. 20-5,000 Hz, ± 0.5% F.S.
RMS
±0.25% of rdg. 50-500Hz, ± 0.1% F.S. 20-5,000 Hz, ± 0.5% F.S.
20.00-5,000Hz
mtr
RMS
Range
Resolution
Accuracy
Range
Resolution
Accuracy
Range
Resolution
Accuracy
Resolution
Accuracy
Resolution
Accuracy
Range
Resolution
Accuracy
UPC-3M/UPC-3
0-354 V
, 708V
L-N
0.1V front panel
±0.2% F.S plus Cal ref.
1Ø = 60A
, 3Ø = 20A
RMS
0.01A front panel
±0.2% F.S plus Cal ref.
1Ø = 21,240/Ø (W or VA), 3Ø = 7,080/Ø (W or VA)
1.0 Watt or VA front panel
± 1% full range
Calculated and displayed to three digits following the decimal point.
± 1 % full range
Calculated and displayed to three digits following the decimal point.
± 1 % full range
15.00 -1,200 Hz
10.00-99.99 Hz, 0.01 Hz
100.0-999.9 Hz, 0.1 Hz 1,000-5,000 Hz, 1 Hz
± 0.01% full range
(1)
ARMS
Page 4
320AMXT Power Source with optional
external transformer module
5U
(8.75",
222mm)
320AMX-320AMXT
19" (483mm)
19" (483mm)
3U
(5.25",
133mm)
16.75" (426mm)
Temperature
Humidity
Cooling
Altitude
Heat Dissipation
Audible Noise
Agency Approvals
Hardware
Programmable Current Limit
Programmable Current Protect
17" (432mm)
General/Environmental
Operating: 0° to 55° C Storage: -10 ° to 70° C
0 - 95%, Non-condensing
Front and side forced air intake (300 CFM) with rear exhaust.
Operating: 6,500 Ft (1,981m) Storage: 40,000 Ft (12,192 m)
2.2kBTU/ hr (Full kW Load)
65 dba Max @ 1 Meter
Safety UL 61010 -1
EN 61010 -1
EMC EN 61326 -1
Protection and Safety
Over-current, short circuit, over- temperature
A single RMS programmed, average responding, value is provided for all phases. Limits current by reducing output voltage.
Allows the power source to operate in "constant voltage" mode, interrupting output when specied current protect limit is exceeded.
320AMXT-UPC3 Power Source with optional external high range transformer module.
Mechanical Specications
320AMX: 5U (8.75", 222mm)
Height
Transformer Module: 3U (5.25", 133mm)
320AMX: 23.12" (587mm)
Depth
Transformer Module: 3U (5.25", 133mm) (Approx. from front panel to the rear of chassis.)
320AMX: 125 lbs (56.8kg)
Weight
Transformer Module: 125 lbs (56.8kg)
Mounting
Standard 19" rack (483mm). Cabinet options available.
Hardware Options
RS232 Interface. 38.4kbps, (Standard on UPC-3)
/S
/G GPIB Interface, IEEE-488.2. (Standard on UPC-32)
/M7073 Safety Interlock Normally Open Contacts
/M99413
/MXXXXX
Safety Interlock Normally Closed Contacts
Other factory specied modication
Software/Firmware Options
/Prog-Z
Programmable Output Impedance
Harmonic Analysis and Synthesis
/HAS
In-Rush Meter. Capture and view peak in-rush current
/IR
values via front panel or remote interface (UPC-3 only).
Test MGR
Test SEQ
UPC Test Manager License: Create, edit, and execute Test sequences and reports. Ordered as separate line Item
Avionics test sequences; DO-160, ABD-0100, ABD-0100 (A350), Ordered as separate line item, Requires 'Test' Manager License.
Ordering Information
Model Controller
320AMX
320AMXT
UPC-3M
UPC-3
UPC-32
Order Example
320AMXT-UPC32, T= 2.0:1, VIN: 220/380VAC
6kVA, 3-Phase, AC Power Source with optional transformer assembly and UPC-32 programmable controller.
Standard GPIB Interface
2.0:1 Transformer Ratio
220/380VAC, 3 Phase Input Voltage
Options
See List Above
T-Ratio (320AMXT Only)
Ratio 1.5:1
Ratio 2.0:1
Ratio 2.5:1
Input Voltage (VIN)
208 VACΔ ± 10%, 47-63Hz
220VACΔ ± 10%, 47-63Hz
240VACΔ ± 10%, 47-63Hz
220/380VACΔ ±10%, 47-63Hz
240/416 VACΔ ±10%, 47-63Hz
277/480 VACΔ ±10%,47- 63Hz
Typical Delivery Items
AC Power Source
English Manuals (AC Source and Controller)
UPC Studio Software - (Download)
UPC Interactive LabVIEW (Download)
Compliance Certicate with Test data
CE Conformity Document (CE Models)
TM
Libraries
Available Models
With Manual Controller
320AMX-UPC3M 320AMXT-UPC3M
With Programmable Controller
320AMX-UPC3 320AMXT-UPC3 320AMX-UPC32 320AMXT-UPC32
17692 Fitch, Irvine, CA 92614 USA
Phone: +1 949.251.1800
Fax: +1 949.756.0756
Toll Free: 800.854.2433
E-mail: sales@pacicpower.com
www.pacicpower.com
© 2013 Pacic Power Source, Inc. Subject to change without notice. #DS320AMX0713