Atec 320AMX User Manual

Models 320AMX-320AMXT
2,000VA
20-5,000 Hz
0-338V
4
0-600V
4
0-338VL-N / 585VL-L
4
L-N
L-L
1, 2, or 3Ø – Linear AC Power Source
Standard Features:
Advanced Linear Ampliers Provide Very Low Voltage Distortion, no Switching Noise, Fast Voltage and Current Slew Rates, Exceptionally Low Output Impedance and High Peak Current Capability
1, 2, or 3 Phase Output Form selectable from front panel or bus command
Precision Voltage Programming – 0.05% with Continuous Self-Calibration (CSC) engaged
True-RMS Metering of Volts, Amps, and Power
GPIB (IEEE-488.2) or RS-232 Interface
Waveform Library – Arbitrary Waveform Generator
Up to 99 Programs with Associated Transients for Static and Dynamic Test Applications
UPC Studio Software Suite
Available Options:
T-versions include external transformer assembly for higher voltage ranges
Programmable Output Impedance
Harmonic Analysis and Waveform Synthesis
Peak Inrush Capture and Waveform Analysis (Available on models with UPC3 controller)
UPC Test Manager Software
Model 320AMX
As a member of Pacic Power’s AMX-Series popular family of high performance Linear AC Power Sources, the 320AMX oers the same low output voltage noise and distortion, ease of installation, and high AC waveform delity as found in all of Pacic Power’s Linear AC Power Sources. Control and operational features provide a high degree of versatility and ease of use for applications ranging from simple, manually controlled frequency conversion to harmonic testing and sophisticated programmable transient simulation.
AC TEST POWER
All 320AMX and 320AMXT models are equipped with a powerful micro-controller with the ability to operate as a fully integrated test system. This enables a variety of power conditions and transients to be applied to the device under test while metering and analyzing all output performance parameters. For higher power requirements, refer to the AMX & ASX series catalog.
FREQUENCY/ VOLTAGE CONVERSION
The 320AMX is an excellent source of stable AC Voltage over the frequency range of 20 to 5,000 Hz (Direct Coupled Range) or 45 to 5,000 Hz (Transformer Coupled AMXT models) when using the high-end UPC-32 controller. Also available in 1,200 Hz maximum output frequency when using UPC3 or Manual controller. The output frequency is quartz-crystal stabilized. Output voltages up to 270V mode are available on the 320AMX model and up to 600V 320AMXT model.
PHASE CONVERSION
With the ability to provide either single or two phase output, the 320AMX is a good choice to convert three-phase line voltage into precisely controlled split (two-phase) or single­phase output power.
in split phase mode and 234V
L-L
in three phase mode on the
L-L
in three phase
L-L
UPC Manager Software Suite
Master the Power of the Wave!
UPC SERIES CONTROLLER
Three controller models are available in both manual and programmable control version. All controllers provide manual operation from the front panel. Programmable
UPC Manager Software gives you the tools necessary to quickly and easily operate your AC Power Source. With our graphical interface control all areas of your AC Power Source testing with simple presets, user prompts, test sequences, test plans and custom reports.
Controllers may be operated from the front panel or from a remote interface via RS 232 or GPIB.
The Leader in AC Power Technology
An early pioneer in the development solid-state power conversion equipment, Pacic Power Source continues to develop, manufacture, and market both linear and high-performance PWM AC Power Sources. Pacic Power Source’s reputation as a market and technology leader is best demonstrated by its continuing investments in both research and development and world-wide customer support. With corporate owned oces in the United States, Germany, the United Kingdom, and China, local personalized support is always available.
THE POWER OF EXPERTISE
FREQUENCY CONVERSION R & D MANUFACTURINGAEROSPACE MILITARY CUSTOM
320AMX-320AMXT
Output Ratings
320AMX
Output Voltage3
Rated Power (VA)
2,000
1
Coupling Mode
Direct 1Ø/2Ø
Form
2
V
Max
RMS
(L-N/L-L)
135/270 135/234
320AMXT
Output Voltage3
1
Rated Power (VA)
2,000
Coupling Mode
Direct
Transformer 1.5:1
Transformer 2.0:1
Transformer 2.5:1
NOTES:
1. Rated output power is based on a combination of nominal output voltage, rated current and load power factor. Values stated represent the maximum capabilities of a given model (maximum power in split phase (Form2) direct coupled mode is 1.3 kVA). Consult factory for assistance in determining specic unit capabilities as they might apply to your application.
2. Unit is operable as single phase with dual range capability or 3 phase. Output voltage range and 1/2/3 conversions are selected by front panel or bus commands.
3. Vmax is output voltage with nominal input and full rated load applied.
4. Available current will vary with output voltage and power factor. Current shown is per phase.
AMX Power Source Specications (PF = 1.0, V
Output Frequency
Full Power
20-5,000 Hz Direct Coupled
45-5,000 Hz Transformer Coupled
Line Regulation
0.1% max for a ±10% line
change
2
Form
1Ø/2Ø
1Ø/2Ø
1Ø/2Ø
1Ø/2Ø
V
Max
RMS
(L-N/L-L)
135/270 135/234
202/404 202/350
270/540 270/468
338/600 338/585
out
> 25% F.S.)
Load Regulation
Direct Coupled Ranges:
0.25% 20 to 2,000 Hz.
0.50% 2,000 to 5,000 Hz.
Improves to less than 0.03% with external sense and CSC enabled.
Transformer Coupled Ranges:
Improve to < 0.1% with external sense and CSC enabled.
Input Power Requirements (47-63 Hz)
Input Voltage
Input Current
Recommended
Input service
208VAC 3ØΔ
±10%
11A
RMS
20A
220VAC 3ØΔ
±10%
10A
RMS
20A
Thermal and Power Factor Rating Curves
Rated Continuous Load Current as a Function of Ambient Temperature and Power Factor and Output Voltage at Nominal Input Line.
Current
(A
RMS
18/6
6/Ø
Current
(A
RMS
18/6
6/Ø
12/4 4/Ø
9/3 3/Ø
7.2/2.4
2.4/Ø
1:5:1 2% 2:0:1 4% 2:5:1 5%
240VAC 3ØΔ
4
)
4
)
±10%
9A
20A
RMS
Frequency
Range
20-5000
Frequency
Range
20-5000
45-5000
45-5000
45-5000
47-63Hz
47-63Hz
Output Distortion
0.1% THD
AVG
0.25% THD
220/380VAC
±10%
6A
RMS
10A
Input
Power
Input
Power
45 to 1,000 Hz
20 to 5,000 Hz
AVG
Unit Height
In/mm/U
8.75/222/5U
Unit Height
In/mm/U
320AMX
8.75/222/5U
Transformer Module
5.25/133/3U
Ripple and Noise
-72dB
240/416VAC
±10%
5A
RMS
10A
Unit Weight
(Lbs/Kg)
125/56.8
Unit Weight
(Lbs/Kg)
320AMX
125 /56.8
Transformer
Module
125 /56.8
Response Time
5 µsec typ. For
step load change.
Small signal
bandwidth = 5 Hz
to 40 KHz
277/480VAC
±10%
(Cost Option)
5A
RMS
10A
THERMAL RATING -AC CURRENT RMS Short tem overloads to 150% of rated current are permitted. Operating time before thermal shutdown or circuit breaker trip varies from seconds to several minutes depending upon line
and temperature conditions.
OUTPUT VOLTAGE-AC VOLTS RMS
Short term overloads to 150% are permitted. Operating time before thermal shutdown or circuit breaker trip varies from seconds to several minutes depending upon line and tempera­ture conditions.
Loading...