Models 320AMX-320AMXT
2,000VA
20-5,000 Hz
0-338V
1Ø4
0-600V
2Ø4
0-338VL-N / 585VL-L
3Ø4
L-N
L-L
1, 2, or 3Ø – Linear AC Power Source
Standard Features:
• Advanced Linear Ampliers Provide Very Low
Voltage Distortion, no Switching Noise, Fast
Voltage and Current Slew Rates, Exceptionally
Low Output Impedance and High Peak
Current Capability
• 1, 2, or 3 Phase Output Form selectable from
front panel or bus command
• 20 to 5,000 Hz. Full Power Bandwidth
Operation – 5Hz to 50KHz small signal
bandwidth, 3dB at 10% of full voltage
• Precision Voltage Programming – 0.05% with
Continuous Self-Calibration (CSC) engaged
• True-RMS Metering of Volts, Amps, and Power
• GPIB (IEEE-488.2) or RS-232 Interface
• Waveform Library – Arbitrary Waveform
Generator
• Up to 99 Programs with Associated Transients
for Static and Dynamic Test Applications
• UPC Studio Software Suite
Available Options:
• T-versions include external transformer
assembly for higher voltage ranges
• Programmable Output Impedance
• Harmonic Analysis and Waveform Synthesis
• Peak Inrush Capture and Waveform Analysis
(Available on models with UPC3 controller)
• UPC Test Manager Software
Model 320AMX
As a member of Pacic Power’s AMX-Series popular family of high performance
Linear AC Power Sources, the 320AMX oers the same low output voltage noise
and distortion, ease of installation, and high AC waveform delity as found in all of
Pacic Power’s Linear AC Power Sources. Control and operational features provide
a high degree of versatility and ease of use for applications ranging from simple,
manually controlled frequency conversion to harmonic testing and sophisticated
programmable transient simulation.
AC TEST POWER
All 320AMX and 320AMXT models are equipped with a powerful micro-controller with the
ability to operate as a fully integrated test system. This enables a variety of power conditions
and transients to be applied to the device under test while metering and analyzing all
output performance parameters. For higher power requirements, refer to the AMX & ASX
series catalog.
FREQUENCY/ VOLTAGE CONVERSION
The 320AMX is an excellent source of stable AC Voltage over the frequency range of 20 to
5,000 Hz (Direct Coupled Range) or 45 to 5,000 Hz (Transformer Coupled AMXT models)
when using the high-end UPC-32 controller. Also available in 1,200 Hz maximum output
frequency when using UPC3 or Manual controller. The output frequency is quartz-crystal
stabilized. Output voltages up to 270V
mode are available on the 320AMX model and up to 600V
320AMXT model.
PHASE CONVERSION
With the ability to provide either single or two phase output, the 320AMX is a good choice
to convert three-phase line voltage into precisely controlled split (two-phase) or singlephase output power.
in split phase mode and 234V
L-L
in three phase mode on the
L-L
in three phase
L-L
UPC Manager Software Suite
Master the Power of the Wave!
UPC SERIES CONTROLLER
Three controller models are available in both manual and programmable control
version. All controllers provide manual operation from the front panel. Programmable
UPC Manager Software
gives you the tools
necessary to quickly
and easily operate your
AC Power Source. With
our graphical interface
control all areas of your
AC Power Source testing
with simple presets, user
prompts, test sequences,
test plans and custom
reports.
Controllers may be operated from the front panel or from a remote interface via RS
232 or GPIB.
The Leader in AC Power Technology
An early pioneer in the development solid-state power conversion equipment,
Pacic Power Source continues to develop, manufacture, and market both linear and
high-performance PWM AC Power Sources. Pacic Power Source’s reputation as a
market and technology leader is best demonstrated by its continuing investments in
both research and development and world-wide customer support. With corporate
owned oces in the United States, Germany, the United Kingdom, and China, local
personalized support is always available.
THE POWER OF EXPERTISE
FREQUENCY CONVERSION R & D MANUFACTURINGAEROSPACE MILITARY CUSTOM
320AMX-320AMXT
Output Ratings
320AMX
Output Voltage3
Rated Power (VA)
2,000
1
Coupling Mode
Direct 1Ø/2Ø
Form
3Ø
2
V
Max
RMS
(L-N/L-L)
135/270
135/234
320AMXT
Output Voltage3
1
Rated Power (VA)
2,000
Coupling Mode
Direct
Transformer 1.5:1
Transformer 2.0:1
Transformer 2.5:1
NOTES:
1. Rated output power is based on a combination of nominal output voltage, rated current and load power factor. Values stated represent the maximum capabilities of a given model (maximum power in split phase (Form2) direct
coupled mode is 1.3 kVA). Consult factory for assistance in determining specic unit capabilities as they might apply to your application.
2. Unit is operable as single phase with dual range capability or 3 phase. Output voltage range and 1/2/3 conversions are selected by front panel or bus commands.
3. Vmax is output voltage with nominal input and full rated load applied.
4. Available current will vary with output voltage and power factor. Current shown is per phase.
AMX Power Source Specications (PF = 1.0, V
Output Frequency
Full Power
20-5,000 Hz Direct Coupled
45-5,000 Hz Transformer Coupled
Line Regulation
0.1% max for a
±10% line
change
2
Form
1Ø/2Ø
3Ø
1Ø/2Ø
3Ø
1Ø/2Ø
3Ø
1Ø/2Ø
3Ø
V
Max
RMS
(L-N/L-L)
135/270
135/234
202/404
202/350
270/540
270/468
338/600
338/585
out
> 25% F.S.)
Load Regulation
Direct Coupled Ranges:
0.25% 20 to 2,000 Hz.
0.50% 2,000 to 5,000 Hz.
Improves to less than 0.03% with external sense and CSC enabled.
Transformer Coupled Ranges:
Improve to < 0.1% with external sense and CSC enabled.
Input Power Requirements (47-63 Hz)
Input Voltage
Input Current
Recommended
Input service
208VAC 3ØΔ
±10%
11A
RMS
20A
220VAC 3ØΔ
±10%
10A
RMS
20A
Thermal and Power Factor Rating Curves
Rated Continuous Load Current as a Function of Ambient Temperature and Power Factor and Output Voltage at Nominal Input Line.
Current
(A
RMS
18/6
6/Ø
Current
(A
RMS
18/6
6/Ø
12/4
4/Ø
9/3
3/Ø
7.2/2.4
2.4/Ø
1:5:1 2%
2:0:1 4%
2:5:1 5%
240VAC 3ØΔ
4
)
4
)
±10%
9A
20A
RMS
Frequency
Range
20-5000
Frequency
Range
20-5000
45-5000
45-5000
45-5000
47-63Hz
47-63Hz
Output Distortion
0.1% THD
AVG
0.25% THD
220/380VAC
±10%
6A
RMS
10A
Input
Power
3Ø
Input
Power
3Ø
45 to 1,000 Hz
20 to 5,000 Hz
AVG
Unit Height
In/mm/U
8.75/222/5U
Unit Height
In/mm/U
320AMX
8.75/222/5U
Transformer Module
5.25/133/3U
Ripple and Noise
-72dB
240/416VAC
±10%
5A
RMS
10A
Unit Weight
(Lbs/Kg)
125/56.8
Unit Weight
(Lbs/Kg)
320AMX
125 /56.8
Transformer
Module
125 /56.8
Response Time
5 µsec typ. For
step load change.
Small signal
bandwidth = 5 Hz
to 40 KHz
277/480VAC
±10%
(Cost Option)
5A
RMS
10A
THERMAL RATING -AC CURRENT RMS
Short tem overloads to 150% of rated current are permitted.
Operating time before thermal shutdown or circuit breaker trip
varies from seconds to several minutes depending upon line
and temperature conditions.
OUTPUT VOLTAGE-AC VOLTS RMS
Short term overloads to 150% are permitted. Operating time
before thermal shutdown or circuit breaker trip varies from
seconds to several minutes depending upon line and temperature conditions.