Model 3120-ASX
12kVA – High Performance AC Power Source
Single, Split, or Three Phase Frequency Converter
The Model 3120-ASX is Pacic’s latest addition to its line of Manual
and Programmable AC Power Sources. Power Conversion within the
ASX Series is achieved by high frequency pulse width modulation,
resulting in cool, quiet and efcient operation.
The 3120-ASX is ideal for AC test, frequency conversion,
laboratory and bench-power applications.
AC TEST POWER
The 3120ASX is equipped with the UPC Programmable Controller,
a powerful micro-controller used to create a fully integrated test
system. It supplies a variety of power conditions to the device under
test and meters/analyzes all output performance parameters.
FREQUENCY/VOLTAGE CONVERSION
The 3120-ASX is an excellent source of stable AC Voltage over
the frequency range of 15 to 1,200Hz. The output frequency is
quartz-crystal stabilized. Output voltages up to 600V are available.
17692 Fitch
Irvine, California, USA 92614
+1 800-854-2433
Tel: +1 949-251-1800
Fax: +1 949-756-0756
PHASE CONVERSION
With the ability to provide single and three-phase outputs, the
3120ASX is the perfect choice to provide three-phase input to split (two-phase) or single-phase output power conversion.
Standard FEATURES of each system include:
• 22 Waveform Library – Arbitrary Waveform Generator
• 15 to 1,200Hz Operation – 5,000 Hz Small Signal Bandwidth
• Precision Voltage Programming – 0.05% with
Continuous Self-Calibration (CSC) engaged
• Precision True-RMS metering of volts, amps, and power
for displays and reporting
• RS-232 interface with SCPI
• 1 phase/3 phase Switch Selectable Output from front
panel or bus command
• 99 steady state programs with associated transients
for static and dynamic test applications
Available Options with each system include:
GPIB (IEEE-488.2) Interface with SCPI•
Programmable Output Impedance•
Harmonic Analysis (FFT) and Waveform Synthesis•
Peak Inrush Capture and Waveform Analysis•
LabVIEW for Windows•
Instrument Drivers
UPC Manager Software Suite•
Wide range of Output Magnetics for worldwide testing•
™
and LabWindows™
UPC SERIES CONTROLLER
The latest additions to Pacic’s family of UPC Controllers are the UPC-3M and UPC-3. The UPC Controller is a modular
component of the ASX Series and is available in either Manual or Programmable Congurations.
All UPC Controllers include precise metering functions with data displayed via a 160-character LCD display.
This, along with the 30-key front panel, provides the industry’s most powerful and user-friendly controller.
The UPC-3 is available with either RS-232 or GPIB remote interface. Commands are structured in accordance with SCPI
(Standard Commands for Programmable Instruments). The RS-232 serial port operates up to 38.4kBps. The GPIB interface
is compatible with the IEEE-488.2.
Model 3120-ASX
12kVA – High Performance AC Power Source
MODEL 3120ASX-UPC3 SUMMARY TABLE
Irvine, California, USA 92614
+1 800-854-2433
Tel: +1 949-251-1800
Fax: +1 949-756-0756
MODEL
RATED
POWER
(VA)
OUTPUT
(Note 2)
FORM
OUTPUT
VOLTS
MAX
V
rms
(Note 3)
OUTPUT
AMPS
(Note 6)
MAX
rms
(A
)
OUTPUT
(Note 4)
AMPS
(APk)
OUTPUT
MAGNETICS
INPUT
POWER
FORM
PANEL
HEIGHT
WEIGHT
(LBS.)
1Ø 135 96 300
3120-ASX 12,000
1Ø
(SPLIT)
270 48 150
EXT. 3Ø
15¾"-9U
40cm
215 Lbs.
97.5Kg.
3Ø 135 32 100
NOTES:
1. Rated output power is based on a combination of output voltage, current and load power factor. Values stated represent the maximum capabilities of a given model.
Consult factory for assistance in determining specific unit capabilities as they might apply to your application.
2. Unit is operable as single phase with dual voltage range capability or as a three phase. Output voltage ranges and 1Ø/3Ø conversions are selected by front panel or bus commands.
3. Output voltage range is for standard unit. Vmax is output voltage with nominal input and full rated load applied. Other voltage ranges are available with the output magnetics option.
4. Peak repetitive pulse current for non-linear loads. Consult factory for overload ratings.
5. Three phase input with in-rush limiting: 208, 220, 230, 240, 380, 400, 416, and 480 VAC ± 10%.
6. Available current will vary with output voltage and power factor.
Power Source Specications
OUTPUT FREQUENCY: 15 to 1,200Hz Full Power
Mechanical Specications
The 3120-ASX is designed for operation in 19" equipment racks.
Model is equipped with retractable handles for ease of transportation.
LINE REGULATION: 0.1% Max For ±10% line change
MOUNTING: Standard 19" rack
LOAD REGULATION: 0.25% 15 to 400Hz
0.50% 400 to 1,200Hz
HEIGHT: 9U - 15.75" - 40cm
With external sense enabled
Improves to less than 0.1% with
Continuous Self-Calibration enabled
OUTPUT DISTORTION: 0.25% THD
0.50% THD
15 to 200Hz
AV G
200 to 1,200Hz
AV G
DEPTH: Approximately 24" (61cm), from front panel to the
rear of the chassis.
COOLING: Front or side forced-air intake with rear exhaust.
Automatic Fan Speed Control for low acoustic
noise and extended fan life.
RIPPLE AND NOISE: -66dB
RESPONSE TIME: 60 microseconds typical, 10-90%
load step.
KEY FEATURES UPC SERIES CONTROLLER
PROGRAMMABLE Dynamic output impedance (ZO) is programmable
OUTPUT Range varies with model, but usually results in a
IMPEDANCE: ±10% change in output voltage at maximum-rated
load current. (UPC-3 Option).
PROGRAMMABLE Programmable Current limit is provided on the
CURRENT LIMIT: UPC-3 controllers. Programmable range is from
0 to I
WAVEFORM The UPC-3 controller contains a waveform library
LIBRARY: that stores 22 executable waveforms in Non-volatile
RAM. Waveforms 2-16 are editable via the front
panel or bus command.
WAVEFORM Provides waveform creation by entering the
SYNTHESIS: magnitude (% fund.) and phase angle for the 2nd
through 51st harmonic (UPC-3 option).
©2009 Pacific Power Source
Irvine CA, U.S.A. Subject to change without notice
of the power source.
peak, MAX
WAVEFORM Reports voltage and current harmonic content as
ANALYSIS: as a % of the fundamental and phase angle for
the 2nd through the 51st harmonic. (UPC-3 option).
OUTPUT True RMS reading of each phase is measured
VOLTMETER: independently. Line-to-neutral and line-to-line
voltages are displayed.
OUTPUT True RMS reading of each phase. RMS and Peak
AMMETER: Current, as well as Crest Factor are displayed.
OUTPUT Measures True Power (kW), Apparent Power
POWER: (kVA) and Power Factor.
AUX. Each phase is algebraically summed with UPS
INPUTS: waveform and amplified 25x to the direct coupled
output.
AM INPUTS: ±10 VDC input for each phase modulates the
output voltage ±100%.
#23120ASXDS0509