Atec 3120ASX User Manual

Model 3120-ASX
12kVA – High Performance AC Power Source
Single, Split, or Three Phase Frequency Converter
The Model 3120-ASX is Pacic’s latest addition to its line of Manual and Programmable AC Power Sources. Power Conversion within the ASX Series is achieved by high frequency pulse width modulation, resulting in cool, quiet and efcient operation.
The 3120-ASX is ideal for AC test, frequency conversion, laboratory and bench-power applications.
AC TEST POWER
The 3120ASX is equipped with the UPC Programmable Controller, a powerful micro-controller used to create a fully integrated test system. It supplies a variety of power conditions to the device under test and meters/analyzes all output performance parameters.
FREQUENCY/VOLTAGE CONVERSION
The 3120-ASX is an excellent source of stable AC Voltage over the frequency range of 15 to 1,200Hz. The output frequency is quartz-crystal stabilized. Output voltages up to 600V are available.
17692 Fitch Irvine, California, USA 92614 +1 800-854-2433 Tel: +1 949-251-1800 Fax: +1 949-756-0756
PHASE CONVERSION
With the ability to provide single and three-phase outputs, the 3120ASX is the perfect choice to provide three-phase input to split (two-phase) or single-phase output power conversion.
Standard FEATURES of each system include:
• 22 Waveform Library – Arbitrary Waveform Generator
• 15 to 1,200Hz Operation – 5,000 Hz Small Signal Bandwidth
• Precision Voltage Programming – 0.05% with Continuous Self-Calibration (CSC) engaged
• Precision True-RMS metering of volts, amps, and power for displays and reporting
• RS-232 interface with SCPI
• 1 phase/3 phase Switch Selectable Output from front panel or bus command
• 99 steady state programs with associated transients for static and dynamic test applications
Available Options with each system include:
GPIB (IEEE-488.2) Interface with SCPI• Programmable Output Impedance• Harmonic Analysis (FFT) and Waveform Synthesis• Peak Inrush Capture and Waveform Analysis• LabVIEW for Windows• Instrument Drivers UPC Manager Software Suite• Wide range of Output Magnetics for worldwide testing•
and LabWindows™
UPC SERIES CONTROLLER
The latest additions to Pacic’s family of UPC Controllers are the UPC-3M and UPC-3. The UPC Controller is a modular component of the ASX Series and is available in either Manual or Programmable Congurations.
All UPC Controllers include precise metering functions with data displayed via a 160-character LCD display. This, along with the 30-key front panel, provides the industry’s most powerful and user-friendly controller.
The UPC-3 is available with either RS-232 or GPIB remote interface. Commands are structured in accordance with SCPI (Standard Commands for Programmable Instruments). The RS-232 serial port operates up to 38.4kBps. The GPIB interface is compatible with the IEEE-488.2.
Model 3120-ASX
12kVA – High Performance AC Power Source
MODEL 3120ASX-UPC3 SUMMARY TABLE
Irvine, California, USA 92614 +1 800-854-2433 Tel: +1 949-251-1800 Fax: +1 949-756-0756
MODEL
RATED
POWER
(VA)
OUTPUT
(Note 2)
FORM
OUTPUT
VOLTS
MAX
V
rms
(Note 3)
OUTPUT
AMPS
(Note 6)
MAX
rms
(A
)
OUTPUT
(Note 4)
AMPS
(APk)
OUTPUT
MAGNETICS
INPUT
POWER
FORM
PANEL
HEIGHT
WEIGHT
(LBS.)
135 96 300
3120-ASX 12,000
(SPLIT)
270 48 150
EXT.
15¾"-9U
40cm
215 Lbs.
97.5Kg.
135 32 100
NOTES:
1. Rated output power is based on a combination of output voltage, current and load power factor. Values stated represent the maximum capabilities of a given model. Consult factory for assistance in determining specific unit capabilities as they might apply to your application.
2. Unit is operable as single phase with dual voltage range capability or as a three phase. Output voltage ranges and 1Ø/3Ø conversions are selected by front panel or bus commands.
3. Output voltage range is for standard unit. Vmax is output voltage with nominal input and full rated load applied. Other voltage ranges are available with the output magnetics option.
4. Peak repetitive pulse current for non-linear loads. Consult factory for overload ratings.
5. Three phase input with in-rush limiting: 208, 220, 230, 240, 380, 400, 416, and 480 VAC ± 10%.
6. Available current will vary with output voltage and power factor.
Power Source Specications
OUTPUT FREQUENCY: 15 to 1,200Hz Full Power
Mechanical Specications
The 3120-ASX is designed for operation in 19" equipment racks. Model is equipped with retractable handles for ease of transportation.
LINE REGULATION: 0.1% Max For ±10% line change
MOUNTING: Standard 19" rack
LOAD REGULATION: 0.25% 15 to 400Hz
0.50% 400 to 1,200Hz
HEIGHT: 9U - 15.75" - 40cm With external sense enabled Improves to less than 0.1% with Continuous Self-Calibration enabled
OUTPUT DISTORTION: 0.25% THD
0.50% THD
15 to 200Hz
AV G
200 to 1,200Hz
AV G
DEPTH: Approximately 24" (61cm), from front panel to the
rear of the chassis.
COOLING: Front or side forced-air intake with rear exhaust.
Automatic Fan Speed Control for low acoustic
noise and extended fan life. RIPPLE AND NOISE: -66dB
RESPONSE TIME: 60 microseconds typical, 10-90% load step.
KEY FEATURES UPC SERIES CONTROLLER
PROGRAMMABLE Dynamic output impedance (ZO) is programmable OUTPUT Range varies with model, but usually results in a IMPEDANCE: ±10% change in output voltage at maximum-rated load current. (UPC-3 Option).
PROGRAMMABLE Programmable Current limit is provided on the CURRENT LIMIT: UPC-3 controllers. Programmable range is from 0 to I
WAVEFORM The UPC-3 controller contains a waveform library LIBRARY: that stores 22 executable waveforms in Non-volatile RAM. Waveforms 2-16 are editable via the front panel or bus command.
WAVEFORM Provides waveform creation by entering the SYNTHESIS: magnitude (% fund.) and phase angle for the 2nd through 51st harmonic (UPC-3 option).
©2009 Pacific Power Source Irvine CA, U.S.A. Subject to change without notice
of the power source.
peak, MAX
WAVEFORM Reports voltage and current harmonic content as ANALYSIS: as a % of the fundamental and phase angle for the 2nd through the 51st harmonic. (UPC-3 option).
OUTPUT True RMS reading of each phase is measured VOLTMETER: independently. Line-to-neutral and line-to-line voltages are displayed.
OUTPUT True RMS reading of each phase. RMS and Peak AMMETER: Current, as well as Crest Factor are displayed.
OUTPUT Measures True Power (kW), Apparent Power POWER: (kVA) and Power Factor.
AUX. Each phase is algebraically summed with UPS INPUTS: waveform and amplified 25x to the direct coupled output.
AM INPUTS: ±10 VDC input for each phase modulates the output voltage ±100%.
#23120ASXDS0509