Atec 2503AH User Manual

The 2503AH analyzers measure power, voltage, current and frequency up to 500 kHz with premier precision. Available parameters include V,A,W, Power Factor, Crest Factor, K Factor, THD, Harmonics, Phase, VA, VAR, W.Hr, Triplens, Impedance, Inrush, Mean-Peak Values, Efficiency-Loss, etc.
Xitron power analysis instruments have set the standard for production testing. Independent channel control and unparalleled flexibility and speed have made the 2503AH-3CH the instrument of choice in 3-phase power analysis. The 2503AH­1CH/2CH offers cost effective solutions for single or two-phase applications such as power supply and appliance testing.
High Performance Power Analysis System
2503AH
• 18-bit, 500 kHz sampling speed provides 0.05% basic accuracy
• Ultrafast FFT’s per channel produce measurements in 10ms
• 3000 V Peak, 50 Amp Peak internal shunt and Hall effect CT’s*
• Pre-configured for ballast, motor, power supply and appliance tests
• Real-time, ultra-fast, harmonic analysis
• Application specific configurations
• External CT and PT capability ratio:
0.000001-1000000 to 1, for A/V, A/A or V/V
• Frequency Measurement: 500 µHz to 500kHz, 0.01% of reading
• Measurement Period: User defined from 1 mSec to 27.8 hours
•Watt, VA & VAR Accuracy highest of V* Amp error or Amp* V error yields max. error for either Watts, VA, or VAR
• Accumulation accuracy WHr, VAHr, AHr up to 9999.9 GWHr/GVAHr
• Timing Accuracy: 0.01% + 10 mSec. start/stop error
2503AH high performance Power Analyzers are the most advanced available. Perfect for lighting, power conversion, and appliance test and development applications.
Industries
Served
Lighting
Consumer Products
Medical
Automotive
Regulatory Agencies
Process Control
Power Supply
Power Quality
Monitoring
HVAC
Military
Aerospace
Quality and Reliability
XITRON Technologies, founded in 1990, is the pre­mier source for precision power testing and measure­ment instruments used in industrial manufacturing and medical electronics. Using the latest digital signal processing and circuitry, XITRON’s sophisti­cated technology gives our customers the edge in design verification and product manufacturability. XITRON is ISO 9001:2000, EN46001 registered, and FDA (GMP 820) compliant.
Ordering Information
ITEM # DESCRIPTION
2503AH-1CH Single channel analyzer
2503AH-2CH Two channel analyzer
2503AH-3CH Three channel analyzer
High Performance Power Analysis System
2503AH
Tel: (858) 530-8099 Fax: (858) 530-8077
www.xitrontech.com Email: sales@xitrontech.com support@xitrontech.com
XITRON Technologies Incorporated 9770-A Carroll Centre Road San Diego, California 92126
® Copyright 2005 XITRON Technologies Inc.
Input Ranges
User may select fixed or autorange.
Voltage: 15-30-60-150-300-600-1200 Vrms Current: Shunt: 0.05-0.1-0.2-0.5-1-2-5-10-20 Arms
*Int. CT: 7.5-15-30-60 Arms Bypass: 12.5-25-50-125-250-500 mV RMS, 1.25-2.5-5V RMS All ranges allow for up to 2.5X range peak
Resolution
Better than 0.05% of range
Voltage & Current Accuracy
DC Volts: 0.05% +/- 0.15% range +/- 50 mV DC Amp: 0.05% +/- 0.15% range +/- 200 µA
AC Volts/Amp
0.001Hz-10 kHz 0.05% 10kHz-20kHz 0.10% 20kHz-50kHz 0.33% 50kHz-100kHz 0.55% 100kHz-200kHz 1.00% 200kHz-500kHz 2.35% For voltage add 0.05% of range + 20 mV For internal shunt add 0.05% of range + 100 µA For shunt bypass add 0.05% of range + 10 µV Min input > 10% of range (1% with filter on)
High Accuracy Option
0.05% of reading for freq. 40-400 Hz, and input >25% of range
Hall Effect CT* Accuracy
DC Amp: 0.15% +/- 0. 15%, range +/- 25mA AC Amp: 0.1Hz- 10kHz: 0.25%
10kHz-20kHz 0.65% 20kHz-50kHz: 2.25% 50kHz-100kHz: 4.25 % For AC add 0.05% of range + 10 mA
Crest Factor
Better than 2.5 at full scale input, linearly increasing to 250:1 at 1% of full scale. For max. inputs of 100 Apk, 3000 Vpk
Voltage Protection
Up to 3000 Vpk. Max slew rate 2500 V/uSec
Current Protection
Max 500 Amp peak via HALL effect CT*
Max 15V peak using shunt bypass input
Max. 50 Amp peak using internal shunt
Isolation
Inputs are isolated from each other and ground for voltages up to 3000 Vpk
Settling Time
0.0015 mSec (low pass filter disabled)
Low Pass Filters
User definable 5 Hz - 250 kHz,or disabled
Filter Amplitude Accuracy
Add 0.01%/kHz for signal frequencies > 5 kHz, Filter rejection > 40 dB @ 3x selected filter frequency, current and voltage accuracy specifications apply for input signals < 0.05x selected filter frequency
Harmonic & Spectrum Analysis
Bandwidth: 0.001 Hz to 170 kHz Max. harmonic: 2047 Max FFT size: 4096 point complex FFT, Typical THD, harmonic and phase
accuracy at line frequencies of 50/60 Hz
THD accuracy: +/- 0.3% Harmonic accuracy: 0.03% of range Phase accuracy: 0.1° for freq., <5 kHz, linearly increasing to
5° @ 170 kHz, Fully compliant IEC 1000-3-2 harmonic analysis (Pre-A14)
Power Factor Accuracy
Approximately 0.001 for freq. 10 kHz (5 kHz w/filter) increasing linearly to 0.01 @ 200 kHz (20 kHz w/filter)
AIO Option
Up to twelve analog outputs, proportional to user offset & span of parameters
Analog output level/resolution: 5V/5mA @ 16 bits Accuracy: 0.1% +/- 2mV Digital Range Output: Contact Xitron Technologies
Physical specifications
Power input: 85-265 VRms autoselect, 40-400 Hz @ 100VA max Size: 17.71" wide by 7" high by 14" deep Weight: 24 lbs., 35 lbs. Shipping weight Operating range: 0°C to 50°C, <85% RH @ 40°C non-condensing Storage range: -30°C to 65°C <95% RH @ 40°C non-condensing Configuration: Benchtop or optional 19" rack mount
Digital interfaces (standard)
IEEE488 (1), RS-232 (2) , Parallel Printer
Options
HA: High accuracy calibration 40-400Hz, 0.05% all parameters AIO: 12ea. analog out, 16 digital out
HE 1CH Internal Hall effect for single channel analyzer* HE 2CH Internal Hall effect for two channel analyzer* HE 3CH Internal Hall effect for three channel analyzer* RE 19" Rack Adapter
* Internal HALL effect CT options not available on CE marked units
Condensed Specifications
(Contact XITRON for complete specifications)
Loading...