PROFLINE 2103
3 KVA 1-PHASE HARMONICS AND FLICKER
MEASURING SYSTEM
System
ProfLine 2103 is an accurate and fl exible single phase system designed to measure harmonics and fl icker
in accordance with IEC 61000-3-2 and IEC 61000-3-3, supporting testing on products consuming up to
11 Amps rms and 92 Amp peak @230 Vac. The system is supplied complete with a stable, accurate,
programmable 3 kVA power source. The ProfLine 2103 system is therefore ready to measure and record
any harmonics and fl icker created by the EUT. A wide range of higher power AC source systems are
available from Teseq, please see ProfLine 2105, 2115, 2130, 2145 datasheets for suitable systems at
higher power or for 3-phase operation.
Low cost system for small DUTs
Complete test system including
clean power source
Simulated flicker impedance,
no need for expensive physical
impedance
Measurements are made using precision, no burden, active hall-effect current transformers connected
via a dedicated cable to a multichannel fast Data Acquisition Card (DAQ) fi tted inside a PC. One voltage
and three current measuring channels are used to make simultaneous measurement of both current
and voltage. Calculations are made using dedicated Teseq soft ware (WIN 2100) to determine harmonics
(classes A-D), inter-harmonics, fl icker, dc, dt, dmax, Pst, Plt, inrush current and 24 x dmax.
Impedance
Measurement of fl icker requires a fi xed, stable source impedance as specifi ed in IEC 61000-3-3 (0.24 Ω
+ j0.15 Ω in the line and 0.16 Ω + j0.1 Ω in the neutral). The precision power source (NSG 1007-3) supplied
as part of the system is able to accurately simulate this impedance by careful control of the relationship between voltage and current. This eliminates the need for a costly physical impedance. However,
hardware lumped impedances are available from Teseq, see options list.
Power quality measurement
The power source (NSG 1007-3) supplied as part of the ProfLine 2103 system is able to perform tests in
conformance to a number of immunit y standards. IEC 61000- 4-13 (immunity to harmonics and interharmonics), IEC 61000 -4-14 (voltage fl uctuations), IEC 61000-4-17 (ripple on DC) and IEC 61000-4-28 (variation
of power frequency). Additionally it can also per form pre-compliance testing to IEC 61000-4-29 (voltage
dips, interrupts and variations on DC supply) and IEC 61000-4-11. With the addition of further options
IEC 61000-4-8 (power frequency magnetics) and fully compliant IEC 61000-4-11 (voltage dips, interrupts
and variation on AC supply) can be implemented.
PROFLINE 2103
3 KVA 1-PHASE HARMONICS AND FLICKER
MEASURING SYSTEM
Technical information
Mains supply options ProfLine 2103-240
System contents NSG 1007-3-240 Power source
CCN 1000-1 1-phase coupling unit
DAQ card
Interface cable
WIN 2100 H&F test software
WIN 2110 PQT test software
Pre-confi gured PC
USB cable
Power source (for full specifi cation see separate datasheet)
Power output (AC mode) 3,000 VA
Voltage AC, two ranges 0-150 V and 0-300 V
Maximum current (low range) 22.2 Amps, 110 Amps peak repetitive
Maximum current (high range) 11.1 Amps, 96 Amps peak repetitive
Frequency range (AC mode) 16 Hz – 1000 Hz
Power output (DC mode) 2,100 watts
Voltage DC, two ranges 0-200 V and 0-400 V
Maximum current (low range) 15.6 Amps
Maximum current (high range) 7.8 Amps
Supply 1-phase, 240 Vac L-N, 50/60 Hz
Dimensions (HxWxD) 178 x 483 x 610 mm
Weight 28 kg
Coupling unit
Number of phases 1
Measurement channels 4
EUT connector: Front panel CEE 77
EUT connector: Rear panel Terminal block
Maximum voltage: Front panel 240 Vac
Maximum current: Front panel 16 Arms
Teseq AG
Nordstrasse 11F 4542 Lute rbach Switzerland
T + 41 32 681 40 4 0 F + 41 32 681 40 48
sales@teseq.com w ww.teseq.com
© Februa ry 2011 Teseq®
Specifications subject to change without notice.
®
Tes eq
is an ISO-registered company. Its products
are designed and manufactured under the strict
quality and environmental requirements of the ISO
9001. This documen t has been carefully checked.
However, Teseq
errors or inaccuracies.
®
does not assume any liability for
Maximum voltage: Rear panel 300 Vac
Maximum current: Rear panel 40 Arms (200 A Pk for 10 ms)
Supply power: Voltage 115/230 Vac +/- 10%
Supply power: Current <0.5 A
Supply power: Frequency 50/60 Hz
Dimensions (HxWxD) 89 x 427 x 560 mm
Weight 5 kg
691-267A Februar y 2011