Atec 2003RP User Manual

Page 1
Value / Power
!!
! Programmable Power, Low Cost
!!
Cost effective solution for three phase AC power requirements
!!
! 675 VA Output Power per Phase
!!
5.0 A
!!
! 16 Hz to 5000 Hz Frequency Range
!!
Commercial, Military and Avionics applications
!!
! High Peak Current Capability
!!
Drives a wide variety of non-linear loads
!!
! Optional Measurements
!!
Accurately measures TRMS Volt, TRMS Current, Peak Current, Crest Factor, Real Power and Power Factor
!!
! Remote Control
!!
IEEE-488 and RS232C Interface for automated test applications. Includes Windows™ operating software
RMS
Three Phase
AC Power

Model 2003RP

Model 2003RP

Compact AC Power

Offering simple rotary front panel controls, the 2003RP program­mable AC power source is ideally suited for a wide range of three phase AC power applications.
Selectable input voltage ranges allow this product to be used any­where in the world to provide a con­venient source of variable utility power for the testing and evalua­tion of domestic and commercial equipment.
In addition, the frequency range extends to 5000 Hz, making this product ideal for a wide range of avionics and defense applications.
Accurate measurement functions are available as an option to elimi­nate the need for external test equipment in many test setups. Voltage, current, peak current, power, and power factor for each individual phase output can be read on the large LCD display or over the bus. A programmable current limit function provides overload pro­tection of the unit under test.

Easy To Use Controls

Front panel digital rotary encod­ers are used to set voltage and fre­quency. These controls have an analog feel, with the precision and reliability of digital circuits. Settings and measurements are read di­rectly on the large, high contrast LCD displays.
Dual output voltage ranges of 135 V
L-N and 270 V
RMS
maximum current at the required voltage.
The output frequency can be var­ied from 16 Hz up to 5000 Hz to cover commercial, avionics and defense power applications.
L-N, provide
RMS

Product Development

The precise voltage regulation and wide frequency range of the 2003RP, combined with its easy-to­use front panel, make it a great three phase AC source for lab use. Built in measurements may be added (option -OP1) to extend the unit’s usefulness for design appli­cations of three phase AC products.

Avionics Applications

As an affordable and reliable source of three phase, 400 Hz power, the 2003RP is well suited for commercial and defense avionics applications. In addition to the stan­dard 2003RP, a special avionics version is available (-AV option). This version increases output cur­rent from 5.0 A phase at 115 V uses high frequency output trans­formers and offers a lowest output frequency of 360 Hz. The weight of the 2003RP-AV is 10 % less than that of the standard unit.
to 5.8 A
RMS
. The 2003RP-AV
RMS
RMS
per

Functional Design

The small form factor of the 2003RP makes it convenient to use in a variety of locations. Removable rubber feet protect the work surface if the unit is used in a bench top mode. The low 5.25 inch height also saves valuable rack space when used in a rack and stack system.
Page 2
2003RP - For Easy Transient Programming
Drop transient causes phase A output voltage to drop to zero for one cycle
Voltage Surge transient causes all phase voltages to surge.
Extensive Transient Control
With the addition of option package -OP1, the 2003RP is capable of producing transients with a high degree of user programmability. Set­ting up transient programs is facilitated by a Windows™ Graphical User Interface program that allows amplitude, frequency and event duration to be programmed from a PC. Time resolution is 1 ms (0.001 sec) with a minimum time interval ranging from 1 to 40 ms, depending on the transient type. Maximum transient time intervals are 9999 seconds. Transient programming allows the effects of common line disturbances such as phase loss, voltage surges, sags, drop-outs and frequency fluc­tuations on the unit under test to be evaluated.
1

Precision Measurements

For bench or automated test equipment (ATE) applications, the 2003RP can be ordered with the -OP1 option, offering both IEEE-488 and RS232C remote control interfaces as well as extended measure­ments. These measurements are available from the front panel and over the bus. The 2003RP measurements can be calibrated over the bus, lowering cost of ownership.

SCPI Protocol Programming Commands

All functions of the 2003RP are programmable over the available IEEE-488 or RS232C interface. For example, the following tasks can be performed over the bus:
Set voltage and frequency to any level
Generate voltage dropouts, sags or surges
Measure TRMS current, peak current, crest factor, TRMS voltage,
true power, apparent power and power factor
Recall eight complete instrument setups from non-volatile memory
Adjust current limit value
Lock the front panel to prevent operator interference
Switch between high and low output voltage range
Drop output voltage on one or more phase outputs at specific phase
angles for a user specified duration. (see note 1)

Application Software

Windows™ application software is included with the -OP1 option pack­age. This easy-to-use graphical interface program provides complete control over all instrument functions using the RS232C or IEEE-488
Frequency Sweep transient causes the output frequency to change at a user specified rate.
Voltage Sweep transient causes all phase voltages to change at a programmed rate.
Note 1: Voltage drop outs can be programmed at random phase angles or at 0, 90, 180 and 270 degrees with respect to phase A.
interface. With enhanced capa­bilities such as output sequenc­ing, data logging and transient generation, many applica­tions can be ad­dressed without the need to write software.
Free Windows™ Graphical User Interface software included with option package OP1.
Page 3

Specifications

California Instruments
Total Customer Satisfaction
is the goal of all California In-
struments’ employees. It is the
driving force behind everything
we do. This not only affects the
product that you purchase from
California Instruments, but ev-
erything about your interface
with the company. Our applica-
tions engineers are ready to
assist you with your AC power
application. With over 35 years
of experience designing and
building precision AC power
supplies, chances are we can
meet your needs and exceed
your expectations. The same
dedication to customer satis-
faction you will find in our ap-
plications group also perme-
ates our modern manufactur-
ing facility where our products
are carefully built. No unit
leaves our factory without be-
ing thoroughly tested to ensure
quality, reliability and conform-
ance to specifications.
Voltage, Current and Frequency rating charts
Note 1: All specifications are for L-N. Phase angle specifications are valid under balanced load conditions only. Ambient temp. 23° ± 5° C. Note 2: Supplementary specifications apply outside indicated frequency ranges. 3: At 400 Hz input, nominal line voltage minimum required.
Parameter 2003RP Unit
Controller
Output
Protection
Input
Measurements2 - Specifations valid from 300 - 500 Hz, Phase Selectable. (* Requires Option -OP1)
Remote Control (* Requires Option -OP1)
Physical
Type Programmable Controls Digital Encoders Readouts dual 4 digit LCD’s
No. of Phases 3 (A, B, C) Phase angles A = 0°, B = 240°, C = 120° AC Power Max. per phase 675 VA Load Connection floating neutral Rear panel terminal block
Voltage
Ranges High / Low 0-270/0-135 V Accuracy
Resolution 0.1 V Load Regulation2remote sense, 16 - 500 Hz ± 0.1 % FS Line Regulation 10 % Line change ± 0.02 % FS T.H.D.2 (into a 16 Hz - 100 Hz 0.5 typ./ 1.0 max. %
Output Noise < 0.1 typ. V
Frequency
Range (see V-F rating chart) 16-5000 Hz Accuracy ± 0.02 % Resolution 16.00 Hz - 80.00 Hz 0.01 Hz
Current per Phase (see I-V rating chart)
RMS Current High / Low V range 2.5 / 5.0 A RMS Peak Current High / Low V range 7.5 / 15.0 A
Adj. Current limit Resolution 0.1 A RMS
Over Temperature Over Voltage
Connection Rear panel terminal block Line Voltage 2 wire + GND 96 - 127 V or 187 - 253 V V RMS Line Current < 35 A RMS Line Frequency 47 - 440 Hz Holdup Time 10 ms Isolation Input to Chassis/Output 1350 / 2200 V
Current Range Low / High 0.000-4.000 / 0.00-6.00 A RMS
Peak Current* Range Low / High 0.00-12.00 / 0.0-20.0 A
Voltage* Range 0.0 - 300.0 V RMS
Power* Range 0.0-800.0 W
Power Factor* Range 0.00 - 1.00
Interface* RS232C and IEEE-488
Remote Inhibit* Output shut down TTL in, active low BNC Function Strobe* On V or F change TTL out, active low BNC
Dimensions HxWxD 5.25 x 19 x 22 inches
Weight (net) 85 / 38.3 lbs / kg Vibration and Shock Designed to meet NSTA-1A Temperature Operating 0 to 40 ° C
2
resistive load) 100 Hz - 2000 Hz 1.0 typ./ 2.0 max. %
16 Hz - 100 Hz ± 0.1 % FS 100 Hz - 2000 Hz ± 0.2 % FS
80.1 Hz - 800.0 Hz 0.1 Hz 800 Hz - 5000 Hz 1 Hz
Modes Const. Current or Const. Volt
Accuracy 0.2 % FS + 0.3 % rdng Resolution 0.001 / 0.01 A RMS
Accuracy 0.5 % FS + 0.5 % rdng Resolution 0.01 / 0.1 A
Accuracy 0.1 % FS + 0.05 % rdng Resolution 0.1 V RMS
Accuracy 0.5 % FS Resolution 0.2 W
Resolution 0.01
IEEE Functions SH1, AH1, T8, L3, RL2 RS232C settings 19200,8,n,1 Command Language SCPI
HxWxD 133 x 483 x 560 mm
Storage - 40 to + 85 ° C
RMS
RMS
Page 4

Remote Control Option

The 2003RP can be ordered with an option package (-OP1) to add a combined RS232C and IEEE-488 remote control interface. Front panel and bus measurements are included with this option.

Ordering Information

Models:
2003RP 2000 VA three phase,
rack-mount AC Source
Options:
-AV Avionics version. All
specifications equal to standard 2003RP with the following exceptions:
Voltage ranges:
0-115 / 0-230 V
Frequency range:
360 - 5000 Hz
RMS Current:
2.9 / 5.8 A
Weight:
73 lbs. / 33 Kg
-L22 Locking knobs
2003RP Dimension drawing
RMS
RMS
-OP1 Option package 1:
Measurements
IEEE-488 / RS232C
Interface and GUI software
Remote Inhibit input
Function Strobe
output
-RMS Rack Mount Slides
Supplied with:
Instruction / Programming
Manual
Windows™ Graphical User
Interface (with -OP1 option)
RS232C Serial Cable (with -
OP1 option)

Lower Power Models

For applications requiring up to
2000 VA of single phase output
power, models 801RP, 1251RP and 2001RP offer single phase outputs. The 801RP and 1251RP models are housed in a 3.5 inch high rackmount enclosure. The 2001RP uses the same chassis as the 2003RP. Refer to the 801RP/
1251RP and 2001RP data sheets for details.

Portable AC Sources

For mobile or bench top applica­tions, 1000 VA and 1250 VA por­table AC power sources are avail­able as well. The 1001P and 1251P offer programmable AC power from 16 Hz to 500 Hz at 1000 VA and 1250 VA respectively. For applica­tions that only require fixed voltage and frequency settings, the 1001WP frequency converter pro­vides push button selection of nomi­nal 50 or 60 Hz and 100V, 115V, 220V, 230V and 240V settings. Refer to the P and WP Series data sheet respectively for details.
Customer Support
For technical support and ser­vice, or to discuss your AC power application needs, contact Califor­nia Instruments Corp. or your local representative.
CE Mark
The 2003RP has been fully tested for compliance with all ap­plicable CE Mark requirements.
Contact California Instruments:
Toll-Free: 800-4AC-POWER
800-422-7693
FAX: 858-677-0940
Email: sales@calinst.com
Web page: http://www.calinst.com
9689 Towne Centre Drive, San Diego, CA 92121-1964 (858) 677-9040 FAX : (858) 677-0940
© Copyright 2000, California Instruments Corp. Specifications subject to change without notice Printed in the USA. 2003RPDS 04/00
Loading...