AC/DC/IR HIPOT TESTER MODEL : 19071/19073
Complete Dielectric Testing Solution
The Chroma Hipot Tester 19070 series provide 3 models for choice. The 19071 for AC Hipot testing, the 19073 which combines both AC and DC Hipot with insulation resistance (IR) measurements into a single compact unit. The front panel of the testers make them easy to operate. The digital display and user friendly control allow test parameters and limits to be set easily without activating the high voltage.
The 19070 series electrical safety tester are advanced digital hipots with load and line regulation to ensure the measurement integrity. Multi-step capability allows users to perform up to two tests in a sequence such as AC hipot followed by IR.
The 19071 AC Hipot Tester performs AC dielectric withstand (hipot) tests. The test voltage can be programmed in the range of 50V AC to 5kV AC with a resolution of 1V. Its maximum total output current is 15mA.
The 19073 AC/DC/IR Hipot Tester has all the features of the 19071 plus measurement of insulation resistance. The IR measurement range is from 1Mto 10Gwith test voltages from 50 to 1000V DC.
Ground Fault Interrupters (GFI)
GFI is required by the National Electrical Code in wet locations. Such devices automatically interrupt power when a ground
current >0.5mA exists for more than a few milliseconds to protect users.
Quick Discharge
In DC hipot and IR the device under test is discharged back through the HV transformer. This technique results in a rapid and safe discharge.
Ground Continuity Check
All of the 19070 Series testers have a ground continuity check feature to determine that the resistance, that is between the ground blade of power cord and any exposed metal on the product,is less than 1Ω.
Arc Detection
The 19070 series are sensitive enough to monitor 10µsec current spikes even if they do not exceed the maximum trip current level.
Large LCD display
Users can easy to operate instrument with great view of setting functions and test result .
Ground fault interruption shutdown
the instrument when imbalance
current > 0.5mA , provide the
highest protection capability
TUV approved
CE Certified
Programmable output voltage up to
5kV AC and 6kV DC
Insulation resistance measurements from
1Mto 50G
Ground continuity check with 1limit
Arc detection with programmable limit
Front panel lockout
Large LCD display (240 x 64dot matrix)
can supply great view of test result and
setting functions
Programmable ramp and test times
Programmable high and low limits
Cost effective solution for Hipot and IR
Quick discharge of DUT in IR and DC
Hipot
Storage of 10 test setups with 60 steps
per setup
Remote control
Easy to use
MODEL 19071
19073
AC/DC/IR Hipot Tester
Key Features :
78
1110912
All specifications are subject to change without notice.
Developed and Manufactured by:
CHROMA ATE INC.
Head Office: 43, Wu-Chuan Road, Wu-Ku lnd. Park, Wu-Ku, Taipei Hsien, Taiwan TEL: +886-2-2298-3855 FAX: +886-2-2298-3596 http://www.chromaate.com
U. S. A. 7 Chrysler Irvine CA 92618 TEL: +1-949-421-0355 FAX: +1-949-421-0353 Toll Free: +1-800-478 2026
Distributed by:
Worldwide Distribution and Service Network
19071/19072/19073-2004-02-1000
Europe Max Planckstraat 4 6716 BE Ede The Netherlands Tel: +31-318-648282 Fax: +31-318-648288
China 8F, No.4, Nanyou Tian An Industrial Estate Shenzhen, China Post Code: 518052 Tel: +86-755-2664-4598 Fax: +86-755-2641-9620
19071 AC Hipot Tester 19073 AC/DC/IR Hipot Tester A190701 Remote Control Box A190702 40kV Test Probe
Production testing of appliances, instruments and information technology equipment in accordance with UL, IEC, TUV and other standards such as EN 60335, EN 60950, EN 61010, CSA C22.2 No.1010.1, UL 3111 and UL1950
Transformer electrical safety testing
Electric motor safety testing
Variety of electrical components
Testing of electronic components
Specification
Application
Order Information
Model 19071 19073
Mode ACV ACV/DCV/IR Withstanding Voltage Test
Output Voltage AC : 0.05 ~ 5kV AC : 0.1 ~ 5kV , DC : 0.1 ~ 6kV Load Regulation 1 % + 5V Voltage Resolution 2V Voltage Accuracy 1% + 5 counts Cutoff Current AC : 0.1~20 mA AC : 0.1~20 mA, DC : 0.01~5 mA Current Resolution AC : 1µA, DC : 0.1µA Current Accuracy 1.5% + 5 counts Output Frequency 50/60Hz Test Time 0.1 ~ 999 seconds, continue Ramp up Time 0.1 ~ 999 seconds, off Wave Form Sine wave
Insulation Resistance
Output Voltage - - DC : 50 ~ 1000V Voltage Resolution - - 2V Voltage Accuracy - - 5% + 5 counts IR Range - - 0.1M-50G IR Accuracy ≥ 500V : 1MΩ -1000M±(4% + 5 counts)
1G-10GΩ ± (7% + 5 counts)
- - 10G-50GΩ ± (12% + 5 counts) < 500V : 0.1M-1000MΩ ± (7% + 5 counts) < 500V : 0.1M-1000MΩ ±(10% + 5 counts)
Continuity Check Current 0.1A, 1 ± 0.2, On/Off
Arc Detection
Setting Mode Programmable Setting Detection Current AC : 1mA ~ 15mA, DC : 1mA ~ 5mA Minimum Pulse Width 10 µs approx
Secure Protection Function
Fast Output Cut-off 0.4 ms after NG happen Fast DC discharge 0.2 sec. Ground Fault Interrupt (GFI) 0.5mA ± 0.2mA AC (Low), 5mA ± 2mA AC (High), Close Panel Operation Lock Present password Continuity Check Current 0.1A, 1± 0.2, On/Off
GO/ NG Judgment
Indication, Alarm Go:Short sound ;NG:Long sound Data Hold Last tests data memories Step Hold Step signal trigger On/Off Memory Storage 10 tests setups with 60 steps per setup
General
Operation Environment
Temperature : 0 ~ 40˚C
Humidity : 80% RH
Power Consumption No load : < 60W
With rated load : 300W max.
Power Requirement 100V/120V/ 220V AC ±10%, 240V AC +5%~ -10%,
50/60Hz
Weight 12kg Dimension(W X H X D) 270 X 100 X 350mm
AC/DC/IR.....Hipot.....Tester..........................
1. LINE Switch
2. Window Display
3. Reset Button
4. Start Button
5. Function Keys F1~F4
6. Function Key Display Area
7. High Voltage Output Terminal
8. Common Test Terminal
9. Test Indicator
10. Fail Indicator
11. Pass Indicator
12. Calibration Switch
13. Status Line
14. Remote Control
15. LINE Voltage Selector
16. Power Cord Receptacle
17. Earth Ground Terminal
18. Continuity Check
19. Fan
20. Update Switch
Panel Description
1
65
4
3
2
16
15
13
17
18
14
19
20
Loading...