Atec 115ASX-T User Manual

Models 115ASX-115ASXT
1,500VA
15-1,200 Hz
1Ø – High Performance AC Power Source
0-132V
L-N
Standard Features:
Single phase output from front panel or bus command.
15 to 1,200 Hz. Operation – 5,000 Hz small signal bandwidth.
Precision Voltage Programming – 0.05% with Continuous Self-Calibration (CSC) engaged.
True-RMS metering of volts, amps, and power.
GPIB (IEEE-488.2) or RS-232 Interface.
Waveform Library – Arbitrary Waveform Generator.
99 stored programs with associated transients for static and dynamic test applications.
UPC Studio Software Suite.
UPC Interactive LabVIEWTM Libraries.
Available Options:
T versions include internal transformers for higher voltage ranges
Rack enclosures with caster base
Programmable Output Impedance
Harmonic Analysis and Waveform Synthesis
Peak Inrush Capture and Waveform Analysis
UPC Test Manager Software Application
UPC Manager Software Suite
Master the Power of the Wave!
UPC Manager Software gives you the tools necessary to quickly and easily operate your AC Power Source. With our graphical interface con­trol all areas of your AC Power Source testing with simple presets, user prompts, test sequences, test plans and custom reports.
Model 115ASX
As a member of Paci c's ASX-Series family of high performance AC Power Sources, the 115ASX o ers the low acoustic noise, ease of installation, and maximum power density found in all of Paci c's high frequency, pulse width modulated AC Power Sources. Control and operational features provide a high degree of versatility and ease for applications ranging from simple, manually controlled frequency conversion to harmonic testing and sophisticated bus programmable transient simulation.
AC TEST POWER
The 115ASX is equipped with a powerful micro-controller with the ability to operate as a fully integrated test system. It supplies a variety of power conditions and transients to the device under test while metering and analyzing all output performance parameters.
FREQUENCY/ VOLTAGE CONVERSION
The 115ASX is an excellent source of stable AC Voltage over the frequency range of 15 to 1,200 Hz. The output frequency is quartz-crystal stabilized. Output voltages up to 132VL-L are available on the 115ASX model and up to 330VL-L on the 115ASXT model.
UPC SERIES CONTROLLER
Three controller models are available o ering both manual and programmable control. All controllers provide manual operation from the front panel. Programmable Controllers may be operated from the front panel or from a remote interface via RS 232 or GPIB.
The Leader in AC Power Technology
An early pioneer in the development solid-state power conversion equipment, Paci c Power Source continues to develop, manufacture, and market both linear and high-performance PWM AC Power Sources. Paci c's reputation as a market and technology leader is best demonstrated by its continuing investments in both research and development and world-wide customer support. With corporate owned o ces in the United States, France, the United Kingdom, and China, local personalized support is always available.
THE POWER OF EXPERTISE
FREQUENCY CONVERSION R & D MANUFACTURINGAEROSPACE MILITARY CUSTOM
Output Ratings
115ASX
115 ASXT
115ASX
Rated Power (VA)
1500
115 ASXT
Rated Power (VA)
1500 Direct
1
1
Coupling Mode
Direct
Coupling Mode
Form
Form
Output Voltage
V
rms
(L-N/L-L)
Output Voltage
V
rms
(L-N/L-L)
2
Max
132 16 15-1200
2
Max
132
Current
(A
rms
Current
(A
rms
16
3
)
3
)
Frequency
Range
Frequency
Range
15-1200
Input
Power
Input
Power
115ASX-115ASXT
Unit Height
In/mm/U
5.25/133/3U
Unit Height
In/mm/U
5.25/133/3U
Unit Weight
(Lbs/Kg)
70/32
Unit Weight
(Lbs/Kg)
95/43
Transformer 1.5:1
Transformer 2.0:1
Transformer 2.5:1
NOTES:
1. Rated output power is based on a combination of nominal output voltage, rated current and load power factor. Values stated represent the maximum capabilities of a given model. Consult factory for assistance in determining speci c unit capabilities as they might apply to your application.
2. Vmax is output voltage with nominal input and full rated load applied.
3. Available current will vary with output voltage and power factor.
ASX Power Source Speci cations (PF = 1.0, V
Output
Frequency
Full Power
15-1,200Hz Direct Coupled
45-1,200 Hz Transformer
Coupled
Line Regulation
0.1% max for a ±10% line
change
198
264
330
> 25% F.S.)
out
Load Regulation (Direct coupled)
0.25% 15 to 400 Hz.,
0.50% 400 to 1,200 Hz.
2 to 5% depending on ratio
Improves to <0.1% with external sense and CSC
10.7
6.4
enabled .
45-1200
8
45-1200
45-1200
Output Distortion
0.25% THD
1.25% THD
AVG
AVG
15 to 200 Hz
200 to 1,200 Hz
Ripple and Noise
-66dB
Response Time
60 msec typ.
10-90% load step
Input Power Requirements (47-63 Hz)
Input Voltage
Input Current
Recommended
Unit Service
100VAC
±10%
22
rms
25A 25A
110VAC
±10%
20
rms
120VAC
±10%
18
rms
25A
200VAC
±10%
11
ms
15A
208VAC
±10%
10
rms
15A
220VAC
±10%
10
ms
15A 15A
230VAC
±10%
9
rms
240VAC
±10%
9
rms
15A
* Power Source equipped with soft start feature. In-rush current at application of input power will not exceed recommended input service.
Power Factor Rating Curves
Rated Continuous load current as a function of Power Factor and Output Voltage-Nominal Input Line
Single Phase Mode
OUTPUT VOLTAGE-AC VOLTS RMS
Short term overloads to 20A are permitted. Operating time before thermal shutdown or circuit breaker trip varies from seconds to several minutes depending upon line and temperature conditions.
Loading...