Atec 115ASX-T User Manual

Models 115ASX-115ASXT
1,500VA
15-1,200 Hz
1Ø – High Performance AC Power Source
0-132V
L-N
Standard Features:
Single phase output from front panel or bus command.
15 to 1,200 Hz. Operation – 5,000 Hz small signal bandwidth.
Precision Voltage Programming – 0.05% with Continuous Self-Calibration (CSC) engaged.
True-RMS metering of volts, amps, and power.
GPIB (IEEE-488.2) or RS-232 Interface.
Waveform Library – Arbitrary Waveform Generator.
99 stored programs with associated transients for static and dynamic test applications.
UPC Studio Software Suite.
UPC Interactive LabVIEWTM Libraries.
Available Options:
T versions include internal transformers for higher voltage ranges
Rack enclosures with caster base
Programmable Output Impedance
Harmonic Analysis and Waveform Synthesis
Peak Inrush Capture and Waveform Analysis
UPC Test Manager Software Application
UPC Manager Software Suite
Master the Power of the Wave!
UPC Manager Software gives you the tools necessary to quickly and easily operate your AC Power Source. With our graphical interface con­trol all areas of your AC Power Source testing with simple presets, user prompts, test sequences, test plans and custom reports.
Model 115ASX
As a member of Paci c's ASX-Series family of high performance AC Power Sources, the 115ASX o ers the low acoustic noise, ease of installation, and maximum power density found in all of Paci c's high frequency, pulse width modulated AC Power Sources. Control and operational features provide a high degree of versatility and ease for applications ranging from simple, manually controlled frequency conversion to harmonic testing and sophisticated bus programmable transient simulation.
AC TEST POWER
The 115ASX is equipped with a powerful micro-controller with the ability to operate as a fully integrated test system. It supplies a variety of power conditions and transients to the device under test while metering and analyzing all output performance parameters.
FREQUENCY/ VOLTAGE CONVERSION
The 115ASX is an excellent source of stable AC Voltage over the frequency range of 15 to 1,200 Hz. The output frequency is quartz-crystal stabilized. Output voltages up to 132VL-L are available on the 115ASX model and up to 330VL-L on the 115ASXT model.
UPC SERIES CONTROLLER
Three controller models are available o ering both manual and programmable control. All controllers provide manual operation from the front panel. Programmable Controllers may be operated from the front panel or from a remote interface via RS 232 or GPIB.
The Leader in AC Power Technology
An early pioneer in the development solid-state power conversion equipment, Paci c Power Source continues to develop, manufacture, and market both linear and high-performance PWM AC Power Sources. Paci c's reputation as a market and technology leader is best demonstrated by its continuing investments in both research and development and world-wide customer support. With corporate owned o ces in the United States, France, the United Kingdom, and China, local personalized support is always available.
THE POWER OF EXPERTISE
FREQUENCY CONVERSION R & D MANUFACTURINGAEROSPACE MILITARY CUSTOM
Output Ratings
115ASX
115 ASXT
115ASX
Rated Power (VA)
1500
115 ASXT
Rated Power (VA)
1500 Direct
1
1
Coupling Mode
Direct
Coupling Mode
Form
Form
Output Voltage
V
rms
(L-N/L-L)
Output Voltage
V
rms
(L-N/L-L)
2
Max
132 16 15-1200
2
Max
132
Current
(A
rms
Current
(A
rms
16
3
)
3
)
Frequency
Range
Frequency
Range
15-1200
Input
Power
Input
Power
115ASX-115ASXT
Unit Height
In/mm/U
5.25/133/3U
Unit Height
In/mm/U
5.25/133/3U
Unit Weight
(Lbs/Kg)
70/32
Unit Weight
(Lbs/Kg)
95/43
Transformer 1.5:1
Transformer 2.0:1
Transformer 2.5:1
NOTES:
1. Rated output power is based on a combination of nominal output voltage, rated current and load power factor. Values stated represent the maximum capabilities of a given model. Consult factory for assistance in determining speci c unit capabilities as they might apply to your application.
2. Vmax is output voltage with nominal input and full rated load applied.
3. Available current will vary with output voltage and power factor.
ASX Power Source Speci cations (PF = 1.0, V
Output
Frequency
Full Power
15-1,200Hz Direct Coupled
45-1,200 Hz Transformer
Coupled
Line Regulation
0.1% max for a ±10% line
change
198
264
330
> 25% F.S.)
out
Load Regulation (Direct coupled)
0.25% 15 to 400 Hz.,
0.50% 400 to 1,200 Hz.
2 to 5% depending on ratio
Improves to <0.1% with external sense and CSC
10.7
6.4
enabled .
45-1200
8
45-1200
45-1200
Output Distortion
0.25% THD
1.25% THD
AVG
AVG
15 to 200 Hz
200 to 1,200 Hz
Ripple and Noise
-66dB
Response Time
60 msec typ.
10-90% load step
Input Power Requirements (47-63 Hz)
Input Voltage
Input Current
Recommended
Unit Service
100VAC
±10%
22
rms
25A 25A
110VAC
±10%
20
rms
120VAC
±10%
18
rms
25A
200VAC
±10%
11
ms
15A
208VAC
±10%
10
rms
15A
220VAC
±10%
10
ms
15A 15A
230VAC
±10%
9
rms
240VAC
±10%
9
rms
15A
* Power Source equipped with soft start feature. In-rush current at application of input power will not exceed recommended input service.
Power Factor Rating Curves
Rated Continuous load current as a function of Power Factor and Output Voltage-Nominal Input Line
Single Phase Mode
OUTPUT VOLTAGE-AC VOLTS RMS
Short term overloads to 20A are permitted. Operating time before thermal shutdown or circuit breaker trip varies from seconds to several minutes depending upon line and temperature conditions.
115ASX-115ASXT
Resolution
Accuracy
Total Control, Metering, and Analysis of AC Power - Simple, Intuitive Operation
The UPC Controller is a highly versatile one, two, or three
phase oscillator/signal generator designed to control any of Paci c's AC Power Sources. Three controller models, UPC-1M, UPC-1, or UPC-12are o ered for use with the 115ASX.
Using the front panel keyboard and display, all controller
models provide for selection of power source output mode, coupling, voltage, and frequency. Selecting the correct UPC controller for a given application varies with your test require­ment, desired features, and price.
Both the UPC-1 and UPC-12 Controllers are available
with either RS-232 or GPIB remote interface. Commands are structured in accordance with SCPI (Standard Commands for Programmable Instruments).
Controller Models
Features
Output Modes
Waveform Library
Transient Functions
Program Library
Programmable Current Limit
Programmable Current Protect
Programmable Phase Angle
CSC (Continuous Self-Calibration
Remote Interface
Waveform Synthesis/Analysis
Prog. Output Impedance
Inrush Peak Detect
DRM Link-Synchronization
Line Synchronization
Std Opt
UPC-1M
1Ø 1Ø
Sine
NO
NO
YES
YES YES
NO
YES
NONE NONE
NO
NO
NO
NO
NO NO
UPC-1 UPC-12
Sine +
21 Editable
YES, 50 Steps
99 Programs
YES YES
YES, 0 to 359°
YES
RS-232
GPIB
OPTIONAL OPTIONAL
OPTIONAL
NO
15 Editable
YES, 99 Steps
99 Programs
YES, 0 to 359°
OPTIONALOPTIONAL
OPTIONAL
OPTIONAL
Sine +
YES
YES
GPIB
RS-232
NO
16 Character LCD Display
Parameter Control
Program Edit and Function Key Ouput Control, Slew, and enable Keys
Output Control Speci cations
Frequency
Voltage
Phase Angle
ØB and ØC relative to ØA
Current Limit
UPC-1M/UPC-1
Range
Resolution
Accuracy
Range (l-n)
Resolution
Accuracy
Range
Resolution
Accuracy
Range
Resolution
Accuracy
(1) Full power output limited to 1,200 Hz in ASX models
15-1,200Hz
4 Signi cant Digits
±0.01% of full scale
0 - 150/375
0.1V/ 0.5V
0.5% of full scale (CSC Disabled) ±0. 05% referenced to Internal Meter (CSC Enabled)
0 -359 °
± 1 °
15.00 -150Hz, ± 0.5° ±0. 5°
15.00 - 300 Hz, ± 1°
15.00 - 600 Hz, ± 2°
15.00 - 1,200Hz, ± 3°
1Ø = 0 - 300 Apk
0.05% F.S.
±3% F.S.
UPC-12
20-5,000Hz
3Ø = 0 - 100 Apk
±1% F.S.
Output Metering
(1)
Analog Auxilary Input
AM-Amplitude Modulation
Sync Outputs Zero Crossing
Transient Trigger
Transient Pedestal
Output Clock
Waveform Synthesis
(/HAS Option)
Waveform Analysis
(/HAS Option)
External Inputs/Outputs
Each phase is algebraically summed with UPC waveform and ampli ed 25X to the direct coupled output. ±10Vpk (20Vpk-pk). One input per phase. Z
±10 Vdc (20Vpk-pk) modulates the output voltage ±100% One input per phase. Z
Positive Zero Crossing (0°) of Phase A analog output
Pulse at the start of a transient event. (UPC-12 only)
TTL True when a transient is in progress
UPC-1, TTL level pulse rate varies with output frequency UPC-12, TTL level 1024 x output frequency
= 600 Ω
IN
= 600 Ω
IN
Waveform Control
Creates waveform by entering magnitude as % of fundamental and speci ed phase angle for 2nd through the 51st harmonic
Reports waveform harmonic content and phase angle relative to the fundamental for the 2nd through the 51st harmonic as Total, Odd, and Even harmonic distortion
Voltmeter
True V
rms
phase
Ammeter
True A Apk each phase
Power Meter
True Watts and Volt-Amps each phase
Power Factor
Ratio : kW
mtr
Crest Factor
Ratio: Apk/Arms
Freq. Display
rms
/kVA
each
and
mtr
Range
Resolution
Accuracy
Range
Resolution
Accuracy
Range
Resolution
Accuracy
Resolution
Accuracy
Resolution
Accuracy
Range
Resolution
Accuracy
UPC-1M/UPC-1
0.1 Vrms front panel, 0.001 Vrms via remote interface
±0.2% F.S plus Cal ref.
0.01 Arms or peak front panel, 0.001 Arms via remote interface
±0.2% F.S plus Cal ref.
±1% full range
15.00 -1,200 Hz
0-354 VL-N, 708VL-L
1Ø = 120 Apk, 2Ø = 60Apk
42,480 (W or VA)
1.0 Watt or VA to front panel, 0.001 W or VA via remote interface
Calculated and displayed to three digits following the decimal point.
± 1 % full range
Calculated and displayed to three digits following the decimal point.
± 1 % full range
10.00-99.99 Hz, 0.01 H z
100.0-999.9 Hz, 0.1 Hz 1,000-5,000 Hz, 1 Hz
± 0.01% full range
UPC-12
50-500Hz, ± 0.25% or rdg. ± 0.1% F.S. 20-5,000 Hz, ± 0.5% F.S.
±0.25% of rdg. 50-500Hz, ± 0.1% F.S. 20-5,000 Hz, ± 0.5% F.S.
±0.25% of rdg. plus 50-500Hz, ± 0.1% F.S. 20-5,000 Hz, ± 0.5% F.S.
20.00-5,000Hz
115ASXT-UPC1 Power Source.
19" (483mm)
16.75" (425mm)
General/Environmental Mechanical Speci cations
Temperature:
Humidity:
Cooling:
Altitude:
Heat Dissipation:
Operating: 0° to 55° C Storage: -10 ° to 70° C
0 - 95%, Non-condensing
Side forced air intake (120 CFM) with rear exhaust.
Operating: 6,500 Ft (1,981m) Storage: 40,000 Ft (12,192 m)
750kBTU/ hr (Full kW Load)
115ASX-115ASXT
Height
115ASX: 5U (5.25", 133mm)
Depth
115ASX: 23" (584 mm)
Weight
115ASX - 70 lbs (32kg) 115ASXT 95 lbs (43kg)
Mounting
/M7073 Safety Interlock Normally Open Contacts
Standard 19" rack (483mm). Cabinet options available.
Hardware Options
5U
(5.25",
133mm)
Audible Noise:
Agency Approvals:
Hardware
Programmable Current Limit
Programmable Current Protect
Ordering Information
Model Controller
115ASX
115ASXT
65 dba Max @ 1 Meter
Safety UL 61010 -1 EN 61010 -1 EMC EN 61326 -1
Protection and Safety
Over-current, short circuit, over- temperature
A single RMS programmed, average responding, value provided for all phases. Limits current by reducing output voltage.
Allows the power source to operate in "constant voltage" mode, interrupting output when speci ed current protect limit is exceeded.
T-Ratio (115ASXT Only)
Ratio 1.5:1
Ratio 2.0:1
Ratio 2.5: 1
UPC1M
UPC1
UPC12
Options
See List Above
/M99413
/P000828
/MXXXXX
Test MGR
Input Voltage (V
100 VAC ±10%, 47-63Hz
110 VAC ±10%, 47-63Hz
120 VAC ±10%, 47-63Hz
200 VAC ±10%, 47-63Hz
208 VAC ±10%, 47-63Hz
220 VAC ±10%, 47-63Hz
230 VAC ±10%, 47-63Hz
240 VAC ±10%, 47-63Hz
)
IN
/Prog-z
/HAS
Test SEQ
Safety Interlock Normally Closed Contacts
15U rack enclosure, heavy duty vertical cabinet with casters and rear screen. Ordered as separate line item.
Other factory speci ed modi cation
Software/Firmware Options
/S
RS-232 Interface, 38.4 KBps (std UPC-1)
/G
GPIB Interface, IEEE-488.2, (std UPC-12)
Programmable Output Impedance
Harmonic Analysis and Synthesis
In-Rush Meter. Capture and view peak in-rush current
/IR
values via front panel or remote interface (UPC-3 only).
UPC Test Manager License: Create, edit, and execute Test sequences and reports. Ordered as separate line item.
Avionics test sequences; DO-160, ABD-0100, ABD-0100 (A350), Ordered as separate line item, Requires 'Test' Manager License.
Available Models
With Manual Controller
115ASX-UPC1M 115ASXT-UPC1M
With Programmable Controller
115ASX-UPC1 115ASX-UPC12 115ASXT-UPC1 115ASXT-UPC12
Order Example
115ASXT-UPC1/G, T= 2.0:1, VIN: 120VAC
1500VA, 1-Phase, AC Power Source with optional transformer assembly and UPC-1 programmable controller.
Optional GPIB Interface
• 2.0:1 Transformer Ratio
120VAC, 1 Phase Input Voltage
Typical Delivery Items
AC Power Source
English Manuals (AC Source and Controller)
UPC Studio Software - (Download)
UPC Interactive LabVIEW (Download)
• Compliance Certi cate with Test data
CE Conformity Document (CE Models)
TM
Libraries
17692 Fitch, Irvine, CA 92614 USA
Phone: +1 949.251.1800
Fax: +1 949.756.0756
Toll Free: 800.854.2433
E-mail: sales@pacifi cpower.com
www.pacifi cpower .com
© 2012 Pacifi c Power Source, Inc. Subject to change without notice. #DS115ASX0912