Atec 100HVT User Manual

FEATURES
• Continuously adjustable output from zero to full voltage
• Compact design
• Separate guard and return
• Triple range current meter
• Triple range voltmeter
• Hand cart mounted
• Zero start interlock
• External interlock provision
• Input power circuit breaker
• Fast acting circuit breaker
• 50 kV tap for bucket liner testing.
®
THE MEASURE OF A LEADER
®
100 HVT Series
AC Hipot Tester
BENEFITS
• Test to ANSI/SIA A92.2 1990 specifications
• Ideal for any high voltage AC insulation test requirements
• Portable, for use in the field
• Safe and easy operation
• Low leakage current measurements
• Guard circuit eliminates stray leakage current
APPLICATIONS
• Aerial platform hipoting
• Bucket truck hipoting
• Hot stick testing
• Rotating machinery testing
• Any high voltage AC test requirement (within current limitations)
Model 100 HVT
AC Hipot Tester
DESCRIPTION
The 100 HVT Series AC test sets are specifically designed to perform quick and accurate AC dielectric tests.
The 100 HVT has a maximum output of 100 kV at 50 mA or 50 kV at 100 mA. This test set can be used for testing bucket trucks and aerial platforms, hot sticks, blankets, ropes or any other high voltage AC test requirement. They are particularly suitable for meeting test procedures of the ANSI/SIA A92.2 1990 specification applied to the insulating boom of work platforms and bucket trucks.
A triple range current meter enables low current readings of 0 to 1/10/100 mA on the 100 HVT. A triple range voltmeter is connected directly across the output for maximum accuracy. The 100 HVT has a 50 kV tap that is used for bucket liner testing and other low voltage, high current test requirements.
© Copyright 1996 Hipotronics Inc. All rights reserved. Printed in USA
SPECIFICATIONS
100 HVT Front Panel Layout
INPUT VOLTAGE
MODEL OUTPUT CURRENT METER VOLTMETER DUTY CYCLE OUTPUT TERMINATION METER ACCURACY DISTORTION CABLES
DIMENSIONS NET WEIGHT
HV SECTION
CONTROLS
COMPLETE UNIT
SHIP WEIGHT
Model number suffix - A 120VAC, 60 Hz Model number suffix - B 220VAC, 50/60 Hz
100HVT
100 kV @ 50 mA = 5 kVA/50 kV @ 100 mA = 5 kVA Triple range 0 to 1/10/100 mA Triple range 0 to 25/50/100 kV AC 5 minutes on, 15 minutes off, repeated 6 times, then off for 2 hours High Voltage Toroid ± 2% of Full Range Less than 5% of sinusoidal wave 25' (7.6 meters) Controller to HV Tank with Plug Connection
(2) 25' Shielded Cable for Return and Voltmeter (2) 25' Guard/Ground Cable 10' (3 meters) Input Power Cable
17.4"W x 14.5"D x 31.9"H (441 x 368 x 810 mm)
135 lb (61 kg) 62 lb (28 kg) 240 lb (109 kg) 306 lb (139 kg)
For further information, contact:
Hipotronics, Inc.
A Subsidiary of Hubbell, Incorporated
Route 22, P. O. Box 414
Brewster, NY 10509, U.S.A.
NOTE: Because Hipotronics has a policy of continuous product improvement, it reserves the right to change design and specifications without notice.
100 HVT-DS-2 JUNE 1996
1-800-727-4476
Tel: 845-279-8091
Fax: 845-279-2467
Loading...